High myopia correction by a new phakic intraocular lens with the double optics – a clinical case

Purpose. To report a case of implantation of a new phakic intraocular lens (PIOL) with the double optics, to assess the clinical and functional results of surgical treatment.Material and method. The article presents a 34-year male patient with high myopia in the both eyes. Pre- and postoperative exa...

Full description

Bibliographic Details
Main Authors: G. V. Sorokoletov, V. K. Zuev, E. R. Tumanyan, D. A. Dibina, Z. A. Molova
Format: Article
Language:Russian
Published: Publishing house "Ophthalmology" 2019-07-01
Series:Офтальмохирургия
Subjects:
Online Access:https://www.ophthalmosurgery.ru/jour/article/view/506
id doaj-87b4c34ae1c84d3b971ed6069e65ed92
record_format Article
spelling doaj-87b4c34ae1c84d3b971ed6069e65ed922021-07-28T13:53:40ZrusPublishing house "Ophthalmology"Офтальмохирургия0235-41602312-49702019-07-0102656910.25276/0235-4160-2019-2-65-69407High myopia correction by a new phakic intraocular lens with the double optics – a clinical caseG. V. Sorokoletov0V. K. Zuev1E. R. Tumanyan2D. A. Dibina3Z. A. Molova4The S. Fyodorov Eye Microsurgery Federal State InstitutionThe S. Fyodorov Eye Microsurgery Federal State InstitutionThe S. Fyodorov Eye Microsurgery Federal State InstitutionThe S. Fyodorov Eye Microsurgery Federal State InstitutionThe S. Fyodorov Eye Microsurgery Federal State InstitutionPurpose. To report a case of implantation of a new phakic intraocular lens (PIOL) with the double optics, to assess the clinical and functional results of surgical treatment.Material and method. The article presents a 34-year male patient with high myopia in the both eyes. Pre- and postoperative examinations included: visual acuity measurement, bio-microscopy, ophthalmoscopy, test of visual field, tonometry, endothelial microscopy, ultrasound biomicroscopy (UBM) and optical coherence tomography (OCT). The patient had contraindications for laser refractive surgery, therefore a method of double optics PIOL implantation was proposed. The new PIOL model was implanted in both eyes with an i nterval of 1 week.Results. The operations were successful, without complications. At the postoperative examination of the patient, the uncorrected visual acuity (UCVA) of the right eye was 0.8 and in the left eye was 0.6. The influence of PIOL-3 implantation on IOP was not noted. The performed UBM and OCT of the anterior segment of the eye showed that the haptic elements of the new model PIOL-3 were located in the ciliary sulcus, and there was no contact between the PIOL and the native lens.Conclusions. The new phakic intraocular lens with the double optics performed well for the correction of high myopia throughout the 1-year observation period. It is a safe and effective procedure that allows to obtain a high clinical and functional result, the optical central cylinder in the PIOL design makes a precise placement of the PIOL relative to the optical axis in bright light.https://www.ophthalmosurgery.ru/jour/article/view/506myopiaimplantationphakic intraocular lens (piol)surgical refractive correction
collection DOAJ
language Russian
format Article
sources DOAJ
author G. V. Sorokoletov
V. K. Zuev
E. R. Tumanyan
D. A. Dibina
Z. A. Molova
spellingShingle G. V. Sorokoletov
V. K. Zuev
E. R. Tumanyan
D. A. Dibina
Z. A. Molova
High myopia correction by a new phakic intraocular lens with the double optics – a clinical case
Офтальмохирургия
myopia
implantation
phakic intraocular lens (piol)
surgical refractive correction
author_facet G. V. Sorokoletov
V. K. Zuev
E. R. Tumanyan
D. A. Dibina
Z. A. Molova
author_sort G. V. Sorokoletov
title High myopia correction by a new phakic intraocular lens with the double optics – a clinical case
title_short High myopia correction by a new phakic intraocular lens with the double optics – a clinical case
title_full High myopia correction by a new phakic intraocular lens with the double optics – a clinical case
title_fullStr High myopia correction by a new phakic intraocular lens with the double optics – a clinical case
title_full_unstemmed High myopia correction by a new phakic intraocular lens with the double optics – a clinical case
title_sort high myopia correction by a new phakic intraocular lens with the double optics – a clinical case
publisher Publishing house "Ophthalmology"
series Офтальмохирургия
issn 0235-4160
2312-4970
publishDate 2019-07-01
description Purpose. To report a case of implantation of a new phakic intraocular lens (PIOL) with the double optics, to assess the clinical and functional results of surgical treatment.Material and method. The article presents a 34-year male patient with high myopia in the both eyes. Pre- and postoperative examinations included: visual acuity measurement, bio-microscopy, ophthalmoscopy, test of visual field, tonometry, endothelial microscopy, ultrasound biomicroscopy (UBM) and optical coherence tomography (OCT). The patient had contraindications for laser refractive surgery, therefore a method of double optics PIOL implantation was proposed. The new PIOL model was implanted in both eyes with an i nterval of 1 week.Results. The operations were successful, without complications. At the postoperative examination of the patient, the uncorrected visual acuity (UCVA) of the right eye was 0.8 and in the left eye was 0.6. The influence of PIOL-3 implantation on IOP was not noted. The performed UBM and OCT of the anterior segment of the eye showed that the haptic elements of the new model PIOL-3 were located in the ciliary sulcus, and there was no contact between the PIOL and the native lens.Conclusions. The new phakic intraocular lens with the double optics performed well for the correction of high myopia throughout the 1-year observation period. It is a safe and effective procedure that allows to obtain a high clinical and functional result, the optical central cylinder in the PIOL design makes a precise placement of the PIOL relative to the optical axis in bright light.
topic myopia
implantation
phakic intraocular lens (piol)
surgical refractive correction
url https://www.ophthalmosurgery.ru/jour/article/view/506
work_keys_str_mv AT gvsorokoletov highmyopiacorrectionbyanewphakicintraocularlenswiththedoubleopticsaclinicalcase
AT vkzuev highmyopiacorrectionbyanewphakicintraocularlenswiththedoubleopticsaclinicalcase
AT ertumanyan highmyopiacorrectionbyanewphakicintraocularlenswiththedoubleopticsaclinicalcase
AT dadibina highmyopiacorrectionbyanewphakicintraocularlenswiththedoubleopticsaclinicalcase
AT zamolova highmyopiacorrectionbyanewphakicintraocularlenswiththedoubleopticsaclinicalcase
_version_ 1721270279020216320