Characteristics of a Surgical Snare Using Microwave Energy
Currently, minimally invasive treatments that insert various treatment devices into an endoscope are actively being performed. A high-frequency (HF) snare is commonly used as an energy device inserted into an endoscope. However, using a high-frequency snare, problems usually occur, such as the obstr...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2018-12-01
|
Series: | Diagnostics |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-4418/8/4/83 |
id |
doaj-8785386bd6c1454e827323753e1a93f2 |
---|---|
record_format |
Article |
spelling |
doaj-8785386bd6c1454e827323753e1a93f22020-11-24T23:30:10ZengMDPI AGDiagnostics2075-44182018-12-01848310.3390/diagnostics8040083diagnostics8040083Characteristics of a Surgical Snare Using Microwave EnergyMasashi Sugiyama0Kazuyuki Saito1Graduate School of Science and Engineering, Chiba University, Chiba 263-8522, JapanCenter for Frontier Medical Engineering, Chiba University, Chiba 263-8522, JapanCurrently, minimally invasive treatments that insert various treatment devices into an endoscope are actively being performed. A high-frequency (HF) snare is commonly used as an energy device inserted into an endoscope. However, using a high-frequency snare, problems usually occur, such as the obstruction of the visual field caused by smoke. On the other hand, microwave heating produces less smoke and provides a better visual field. In this study, a snare using microwave energy inserted into an endoscope is proposed, and its characteristics are evaluated.https://www.mdpi.com/2075-4418/8/4/83microwaveEMRsnarenumerical calculation |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Masashi Sugiyama Kazuyuki Saito |
spellingShingle |
Masashi Sugiyama Kazuyuki Saito Characteristics of a Surgical Snare Using Microwave Energy Diagnostics microwave EMR snare numerical calculation |
author_facet |
Masashi Sugiyama Kazuyuki Saito |
author_sort |
Masashi Sugiyama |
title |
Characteristics of a Surgical Snare Using Microwave Energy |
title_short |
Characteristics of a Surgical Snare Using Microwave Energy |
title_full |
Characteristics of a Surgical Snare Using Microwave Energy |
title_fullStr |
Characteristics of a Surgical Snare Using Microwave Energy |
title_full_unstemmed |
Characteristics of a Surgical Snare Using Microwave Energy |
title_sort |
characteristics of a surgical snare using microwave energy |
publisher |
MDPI AG |
series |
Diagnostics |
issn |
2075-4418 |
publishDate |
2018-12-01 |
description |
Currently, minimally invasive treatments that insert various treatment devices into an endoscope are actively being performed. A high-frequency (HF) snare is commonly used as an energy device inserted into an endoscope. However, using a high-frequency snare, problems usually occur, such as the obstruction of the visual field caused by smoke. On the other hand, microwave heating produces less smoke and provides a better visual field. In this study, a snare using microwave energy inserted into an endoscope is proposed, and its characteristics are evaluated. |
topic |
microwave EMR snare numerical calculation |
url |
https://www.mdpi.com/2075-4418/8/4/83 |
work_keys_str_mv |
AT masashisugiyama characteristicsofasurgicalsnareusingmicrowaveenergy AT kazuyukisaito characteristicsofasurgicalsnareusingmicrowaveenergy |
_version_ |
1725542476177997824 |