EXPERIENTIAL INVESTIGATION OF TWO-WAY CONCRETE SLABS WITH OPENINGS REINFORCED WITH GLASS FIBER REINFORCED POLYMER BARS

This research had focused on glass fiber reinforced polymer (GFRP) reinforced concrete flat plate slabs with symmetrical openings. The results of ten interior slab-column connections were presented and discussed. The test parameters are reinforcement ratio, reinforcement type, and openings location....

Full description

Bibliographic Details
Main Authors: MOHANAD T. ABDULJALEEL, AKRAM S. MAHMOUD, ALI R. YOUSIF
Format: Article
Language:English
Published: Taylor's University 2017-04-01
Series:Journal of Engineering Science and Technology
Subjects:
Online Access:http://jestec.taylors.edu.my/Vol%2012%20issue%204%20April%202017/12_4_4.pdf
id doaj-875ebc43578c4de38edf9ec27ea439c0
record_format Article
spelling doaj-875ebc43578c4de38edf9ec27ea439c02020-11-25T02:27:35ZengTaylor's UniversityJournal of Engineering Science and Technology1823-46902017-04-01124898912EXPERIENTIAL INVESTIGATION OF TWO-WAY CONCRETE SLABS WITH OPENINGS REINFORCED WITH GLASS FIBER REINFORCED POLYMER BARSMOHANAD T. ABDULJALEEL0AKRAM S. MAHMOUD1ALI R. YOUSIF2Civil Engineering Department, Engineering College, Anbar University, Ramadi City, Anbar province, IraqCivil Engineering Department, Engineering College, Anbar University, Ramadi City, Anbar province, IraqCivil Engineering Department, Engineering College, Salahaldin University, Erbil, IraqThis research had focused on glass fiber reinforced polymer (GFRP) reinforced concrete flat plate slabs with symmetrical openings. The results of ten interior slab-column connections were presented and discussed. The test parameters are reinforcement ratio, reinforcement type, and openings location. The specimens had been tested under monotonic concentric loading up to failure. The result showed that increasing the reinforcement ratio resulted in higher punching shear-shear capacity, lower deflection, and lower reinforcement ratio. Existing of openings reduced the punching shear capacity, and increased of the deflection, for instance, when spaced of opening's location form column face up to three times of effective depth, it will be issued to increase 25% of punching strength in slab.http://jestec.taylors.edu.my/Vol%2012%20issue%204%20April%202017/12_4_4.pdfGFRP barsFlat plate slabPunching shearOpeningsStrain.
collection DOAJ
language English
format Article
sources DOAJ
author MOHANAD T. ABDULJALEEL
AKRAM S. MAHMOUD
ALI R. YOUSIF
spellingShingle MOHANAD T. ABDULJALEEL
AKRAM S. MAHMOUD
ALI R. YOUSIF
EXPERIENTIAL INVESTIGATION OF TWO-WAY CONCRETE SLABS WITH OPENINGS REINFORCED WITH GLASS FIBER REINFORCED POLYMER BARS
Journal of Engineering Science and Technology
GFRP bars
Flat plate slab
Punching shear
Openings
Strain.
author_facet MOHANAD T. ABDULJALEEL
AKRAM S. MAHMOUD
ALI R. YOUSIF
author_sort MOHANAD T. ABDULJALEEL
title EXPERIENTIAL INVESTIGATION OF TWO-WAY CONCRETE SLABS WITH OPENINGS REINFORCED WITH GLASS FIBER REINFORCED POLYMER BARS
title_short EXPERIENTIAL INVESTIGATION OF TWO-WAY CONCRETE SLABS WITH OPENINGS REINFORCED WITH GLASS FIBER REINFORCED POLYMER BARS
title_full EXPERIENTIAL INVESTIGATION OF TWO-WAY CONCRETE SLABS WITH OPENINGS REINFORCED WITH GLASS FIBER REINFORCED POLYMER BARS
title_fullStr EXPERIENTIAL INVESTIGATION OF TWO-WAY CONCRETE SLABS WITH OPENINGS REINFORCED WITH GLASS FIBER REINFORCED POLYMER BARS
title_full_unstemmed EXPERIENTIAL INVESTIGATION OF TWO-WAY CONCRETE SLABS WITH OPENINGS REINFORCED WITH GLASS FIBER REINFORCED POLYMER BARS
title_sort experiential investigation of two-way concrete slabs with openings reinforced with glass fiber reinforced polymer bars
publisher Taylor's University
series Journal of Engineering Science and Technology
issn 1823-4690
publishDate 2017-04-01
description This research had focused on glass fiber reinforced polymer (GFRP) reinforced concrete flat plate slabs with symmetrical openings. The results of ten interior slab-column connections were presented and discussed. The test parameters are reinforcement ratio, reinforcement type, and openings location. The specimens had been tested under monotonic concentric loading up to failure. The result showed that increasing the reinforcement ratio resulted in higher punching shear-shear capacity, lower deflection, and lower reinforcement ratio. Existing of openings reduced the punching shear capacity, and increased of the deflection, for instance, when spaced of opening's location form column face up to three times of effective depth, it will be issued to increase 25% of punching strength in slab.
topic GFRP bars
Flat plate slab
Punching shear
Openings
Strain.
url http://jestec.taylors.edu.my/Vol%2012%20issue%204%20April%202017/12_4_4.pdf
work_keys_str_mv AT mohanadtabduljaleel experientialinvestigationoftwowayconcreteslabswithopeningsreinforcedwithglassfiberreinforcedpolymerbars
AT akramsmahmoud experientialinvestigationoftwowayconcreteslabswithopeningsreinforcedwithglassfiberreinforcedpolymerbars
AT aliryousif experientialinvestigationoftwowayconcreteslabswithopeningsreinforcedwithglassfiberreinforcedpolymerbars
_version_ 1724842098090311680