Stacked-GRU Based Power System Transient Stability Assessment Method

With the interconnection between large power grids, the issue of security and stability has become increasingly prominent. At present, data-driven power system adaptive transient stability assessment methods have achieved excellent performances by balancing speed and accuracy, but the complicated co...

Full description

Bibliographic Details
Main Authors: Feilai Pan, Jun Li, Bendong Tan, Ciling Zeng, Xinfan Jiang, Li Liu, Jun Yang
Format: Article
Language:English
Published: MDPI AG 2018-08-01
Series:Algorithms
Subjects:
Online Access:http://www.mdpi.com/1999-4893/11/8/121
id doaj-86c9ae7f624e46a18d33527097426f5e
record_format Article
spelling doaj-86c9ae7f624e46a18d33527097426f5e2020-11-24T20:43:52ZengMDPI AGAlgorithms1999-48932018-08-0111812110.3390/a11080121a11080121Stacked-GRU Based Power System Transient Stability Assessment MethodFeilai Pan0Jun Li1Bendong Tan2Ciling Zeng3Xinfan Jiang4Li Liu5Jun Yang6State Grid Hunan Electric Power Company, Changsha 410000, ChinaState Grid Hunan Electric Power Company, Changsha 410000, ChinaSchool of Electrical Engineering, Wuhan University, Wuhan 430000, ChinaState Grid Hunan Electric Power Company, Changsha 410000, ChinaState Grid Hunan Electric Power Company, Changsha 410000, ChinaState Grid Hunan Electric Power Company, Changsha 410000, ChinaSchool of Electrical Engineering, Wuhan University, Wuhan 430000, ChinaWith the interconnection between large power grids, the issue of security and stability has become increasingly prominent. At present, data-driven power system adaptive transient stability assessment methods have achieved excellent performances by balancing speed and accuracy, but the complicated construction and parameters are difficult to obtain. This paper proposes a stacked-GRU (Gated Recurrent Unit)-based transient stability intelligent assessment method, which builds a stacked-GRU model based on time-dependent parameter sharing and spatial stacking. By using the time series data after power system failure, the offline training is performed to obtain the optimal parameters of stacked-GRU. When the application is online, it is assessed by framework of confidence. Basing on New England power system, the performance of proposed adaptive transient stability assessment method is investigated. Simulation results show that the proposed model realizes reliable and accurate assessment of transient stability and it has the advantages of short assessment time with less complex model structure to leave time for emergency control.http://www.mdpi.com/1999-4893/11/8/121data-drivenadaptive transient stability assessmentstacked-GRUtime seriesintelligent assessment system
collection DOAJ
language English
format Article
sources DOAJ
author Feilai Pan
Jun Li
Bendong Tan
Ciling Zeng
Xinfan Jiang
Li Liu
Jun Yang
spellingShingle Feilai Pan
Jun Li
Bendong Tan
Ciling Zeng
Xinfan Jiang
Li Liu
Jun Yang
Stacked-GRU Based Power System Transient Stability Assessment Method
Algorithms
data-driven
adaptive transient stability assessment
stacked-GRU
time series
intelligent assessment system
author_facet Feilai Pan
Jun Li
Bendong Tan
Ciling Zeng
Xinfan Jiang
Li Liu
Jun Yang
author_sort Feilai Pan
title Stacked-GRU Based Power System Transient Stability Assessment Method
title_short Stacked-GRU Based Power System Transient Stability Assessment Method
title_full Stacked-GRU Based Power System Transient Stability Assessment Method
title_fullStr Stacked-GRU Based Power System Transient Stability Assessment Method
title_full_unstemmed Stacked-GRU Based Power System Transient Stability Assessment Method
title_sort stacked-gru based power system transient stability assessment method
publisher MDPI AG
series Algorithms
issn 1999-4893
publishDate 2018-08-01
description With the interconnection between large power grids, the issue of security and stability has become increasingly prominent. At present, data-driven power system adaptive transient stability assessment methods have achieved excellent performances by balancing speed and accuracy, but the complicated construction and parameters are difficult to obtain. This paper proposes a stacked-GRU (Gated Recurrent Unit)-based transient stability intelligent assessment method, which builds a stacked-GRU model based on time-dependent parameter sharing and spatial stacking. By using the time series data after power system failure, the offline training is performed to obtain the optimal parameters of stacked-GRU. When the application is online, it is assessed by framework of confidence. Basing on New England power system, the performance of proposed adaptive transient stability assessment method is investigated. Simulation results show that the proposed model realizes reliable and accurate assessment of transient stability and it has the advantages of short assessment time with less complex model structure to leave time for emergency control.
topic data-driven
adaptive transient stability assessment
stacked-GRU
time series
intelligent assessment system
url http://www.mdpi.com/1999-4893/11/8/121
work_keys_str_mv AT feilaipan stackedgrubasedpowersystemtransientstabilityassessmentmethod
AT junli stackedgrubasedpowersystemtransientstabilityassessmentmethod
AT bendongtan stackedgrubasedpowersystemtransientstabilityassessmentmethod
AT cilingzeng stackedgrubasedpowersystemtransientstabilityassessmentmethod
AT xinfanjiang stackedgrubasedpowersystemtransientstabilityassessmentmethod
AT liliu stackedgrubasedpowersystemtransientstabilityassessmentmethod
AT junyang stackedgrubasedpowersystemtransientstabilityassessmentmethod
_version_ 1716818698107355136