Let home nursing assistant robots see your heart rate

Purpose - This paper aims to design a vision-based non-contact real-time accurate heart rate (HR) measurement framework for home nursing assistant. Design/methodology/approach - The study applied Second-Order Blind Signal Identification (SOBI) algorithm to extract remote HR signal and analyzed it wi...

Full description

Bibliographic Details
Main Authors: Han Wu, Tao Wang, Tuo Dai, Xiaoyu Wang, Yuanzhen Lin, Yizhou Wang
Format: Article
Language:English
Published: Emerald Publishing 2018-12-01
Series:International Journal of Crowd Science
Subjects:
Online Access:https://www.emeraldinsight.com/doi/pdfplus/10.1108/IJCS-09-2018-0023
id doaj-869c5436e2054730a3db9526af63189d
record_format Article
spelling doaj-869c5436e2054730a3db9526af63189d2020-11-25T00:26:09ZengEmerald PublishingInternational Journal of Crowd Science2398-72942018-12-012319821110.1108/IJCS-09-2018-0023619248Let home nursing assistant robots see your heart rateHan Wu0Tao Wang1Tuo Dai2Xiaoyu Wang3Yuanzhen Lin4Yizhou Wang5School of Electronic Engineering and Computer Science, Peking University, Beijing, ChinaSchool of Electronic Engineering and Computer Science, Peking University, Beijing, ChinaSchool of Electronic Engineering and Computer Science, Peking University, Beijing, ChinaSchool of Electronic Engineering and Computer Science, Peking University, Beijing, ChinaSchool of Electronic Engineering and Computer Science, Peking University, Beijing, ChinaSchool of Electronic Engineering and Computer Science, Peking University, Beijing, ChinaPurpose - This paper aims to design a vision-based non-contact real-time accurate heart rate (HR) measurement framework for home nursing assistant. Design/methodology/approach - The study applied Second-Order Blind Signal Identification (SOBI) algorithm to extract remote HR signal and analyzed it with Fast Fourier Transform (FFT). Multiple regions of interest are chosen and analyzed to obtain a more accurate result. Findings - An accurate non-contact hear rate (HR) measurement framework is proposed and proved to be efficient. Originality/value - The contributions of this HR measurement framework are as follows: accurate measurement of HR, real-time performance, robust under various scenes such as conversation, lightweight computation which is suitable and necessary for home nursing assistance. This framework is designed to be flexibly used in various real-life scenes such as domestic health assistance and affectively intelligent agents and is proved to be robust under such scenes.https://www.emeraldinsight.com/doi/pdfplus/10.1108/IJCS-09-2018-0023Crowd AICrowdsourcing human-robot interaction
collection DOAJ
language English
format Article
sources DOAJ
author Han Wu
Tao Wang
Tuo Dai
Xiaoyu Wang
Yuanzhen Lin
Yizhou Wang
spellingShingle Han Wu
Tao Wang
Tuo Dai
Xiaoyu Wang
Yuanzhen Lin
Yizhou Wang
Let home nursing assistant robots see your heart rate
International Journal of Crowd Science
Crowd AI
Crowdsourcing human-robot interaction
author_facet Han Wu
Tao Wang
Tuo Dai
Xiaoyu Wang
Yuanzhen Lin
Yizhou Wang
author_sort Han Wu
title Let home nursing assistant robots see your heart rate
title_short Let home nursing assistant robots see your heart rate
title_full Let home nursing assistant robots see your heart rate
title_fullStr Let home nursing assistant robots see your heart rate
title_full_unstemmed Let home nursing assistant robots see your heart rate
title_sort let home nursing assistant robots see your heart rate
publisher Emerald Publishing
series International Journal of Crowd Science
issn 2398-7294
publishDate 2018-12-01
description Purpose - This paper aims to design a vision-based non-contact real-time accurate heart rate (HR) measurement framework for home nursing assistant. Design/methodology/approach - The study applied Second-Order Blind Signal Identification (SOBI) algorithm to extract remote HR signal and analyzed it with Fast Fourier Transform (FFT). Multiple regions of interest are chosen and analyzed to obtain a more accurate result. Findings - An accurate non-contact hear rate (HR) measurement framework is proposed and proved to be efficient. Originality/value - The contributions of this HR measurement framework are as follows: accurate measurement of HR, real-time performance, robust under various scenes such as conversation, lightweight computation which is suitable and necessary for home nursing assistance. This framework is designed to be flexibly used in various real-life scenes such as domestic health assistance and affectively intelligent agents and is proved to be robust under such scenes.
topic Crowd AI
Crowdsourcing human-robot interaction
url https://www.emeraldinsight.com/doi/pdfplus/10.1108/IJCS-09-2018-0023
work_keys_str_mv AT hanwu lethomenursingassistantrobotsseeyourheartrate
AT taowang lethomenursingassistantrobotsseeyourheartrate
AT tuodai lethomenursingassistantrobotsseeyourheartrate
AT xiaoyuwang lethomenursingassistantrobotsseeyourheartrate
AT yuanzhenlin lethomenursingassistantrobotsseeyourheartrate
AT yizhouwang lethomenursingassistantrobotsseeyourheartrate
_version_ 1725345697541128192