Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study

Aim: The purpose of this in vitro study was to investigate the influence of length and width of implant on primary stability in immediate implants in mandibular first molar. Materials and Methods: The study was carried out on 40 cone-beam computed tomography scans selected with defined inclusion and...

Full description

Bibliographic Details
Main Authors: Arshad Jamal Sayed, Safia Shoeb Shaikh, Shoeb Yakub Shaikh, Mohammed Abid Hussain, Sabahat Ullah Khan Tareen, Vaibhav Awinashe
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2021-01-01
Series:Journal of Pharmacy and Bioallied Sciences
Subjects:
Online Access:http://www.jpbsonline.org/article.asp?issn=0975-7406;year=2021;volume=13;issue=5;spage=484;epage=491;aulast=Sayed
id doaj-860abb6a46514ff1a5fdad853931d5e1
record_format Article
spelling doaj-860abb6a46514ff1a5fdad853931d5e12021-06-15T04:48:43ZengWolters Kluwer Medknow PublicationsJournal of Pharmacy and Bioallied Sciences0975-74062021-01-0113548449110.4103/jpbs.JPBS_818_20Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant studyArshad Jamal SayedSafia Shoeb ShaikhShoeb Yakub ShaikhMohammed Abid HussainSabahat Ullah Khan TareenVaibhav AwinasheAim: The purpose of this in vitro study was to investigate the influence of length and width of implant on primary stability in immediate implants in mandibular first molar. Materials and Methods: The study was carried out on 40 cone-beam computed tomography scans selected with defined inclusion and exclusion criteria. According to the diameter and length of implants, they were divided into nine groups (G1 to G9). The virtual implants of different diameters and length were placed in mandibular first molar and measurements were done for peri-implant horizontal and vertical gap defect, peri-implant interradicular bone support and apical bone support for all the groups. Results: The study groups Diameter, (D-7 mm) showed least horizontal gap defect (Buccal-1.30 ± 0.56 mm, lingual-1.30 ± 0.56 mm, mesial-1.20 ± 0.51 mm, and distal-1.05 ± 0.59 mm) as compared to regular implant diameter (D-4.7) groups (Buccal-2.35 ± 0.483 mm, lingual-2.10 mm ± 0.44 mm, mesial-2.30 ± 0.64 mm, and distal-2.25 ± 0.43 mm). The unsupported Vertical implant gap defect at the coronal part of the socket was 2.80 mm ± 0.83 mm for all groups in both horizontal and vertical direction. The vertical peri-implant interradicular bone support showed increased bone support with increase in implant length (L). The buccal and lingual inter-radicular bone-support was least for Length (L-8.5 mm), moderate for L-11.5 mm, and highest for L-13.5 mm groups, respectively. The mesial inter-radicular bone support was least for G4G7, moderate for G1G2G5G8, and maximum for G3G6G9 groups. Similarly, the distal inter-radicular bone support was least for G4G7, moderate for G1G5G8, and maximum for G2G3G6G9 groups, respectively. There was no apical bone support in L-8.5 mm group as the tip of implant was 3.5–4 mm within the socket tip. Whereas, L-11.5 mm had decent (0.9–1 mm) and L-13.5 mm had Good (1.35–1.95 mm) apical bone support as the implant tip was beyond the socket tip. Conclusion: All the groups showed good interradicular bone support on buccal and lingual surfaces. Regular width implants with longer length showed satisfactory interradicular bone support on mesial and distal surfaces. Longer implants showed good apical bone support in all the four surfaces and hence good apical primary stability expected.http://www.jpbsonline.org/article.asp?issn=0975-7406;year=2021;volume=13;issue=5;spage=484;epage=491;aulast=Sayedbone supportgap defectsimmediate molar implantsimplant length and diameterinter-radicular boneprimary stability
collection DOAJ
language English
format Article
sources DOAJ
author Arshad Jamal Sayed
Safia Shoeb Shaikh
Shoeb Yakub Shaikh
Mohammed Abid Hussain
Sabahat Ullah Khan Tareen
Vaibhav Awinashe
spellingShingle Arshad Jamal Sayed
Safia Shoeb Shaikh
Shoeb Yakub Shaikh
Mohammed Abid Hussain
Sabahat Ullah Khan Tareen
Vaibhav Awinashe
Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study
Journal of Pharmacy and Bioallied Sciences
bone support
gap defects
immediate molar implants
implant length and diameter
inter-radicular bone
primary stability
author_facet Arshad Jamal Sayed
Safia Shoeb Shaikh
Shoeb Yakub Shaikh
Mohammed Abid Hussain
Sabahat Ullah Khan Tareen
Vaibhav Awinashe
author_sort Arshad Jamal Sayed
title Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study
title_short Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study
title_full Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study
title_fullStr Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study
title_full_unstemmed Influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. A cone-beam computed tomography-based simulated implant study
title_sort influence of inter-radicular septal bone quantity in primary stability of immediate molar implants with different length and diameter placed in mandibular region. a cone-beam computed tomography-based simulated implant study
publisher Wolters Kluwer Medknow Publications
series Journal of Pharmacy and Bioallied Sciences
issn 0975-7406
publishDate 2021-01-01
description Aim: The purpose of this in vitro study was to investigate the influence of length and width of implant on primary stability in immediate implants in mandibular first molar. Materials and Methods: The study was carried out on 40 cone-beam computed tomography scans selected with defined inclusion and exclusion criteria. According to the diameter and length of implants, they were divided into nine groups (G1 to G9). The virtual implants of different diameters and length were placed in mandibular first molar and measurements were done for peri-implant horizontal and vertical gap defect, peri-implant interradicular bone support and apical bone support for all the groups. Results: The study groups Diameter, (D-7 mm) showed least horizontal gap defect (Buccal-1.30 ± 0.56 mm, lingual-1.30 ± 0.56 mm, mesial-1.20 ± 0.51 mm, and distal-1.05 ± 0.59 mm) as compared to regular implant diameter (D-4.7) groups (Buccal-2.35 ± 0.483 mm, lingual-2.10 mm ± 0.44 mm, mesial-2.30 ± 0.64 mm, and distal-2.25 ± 0.43 mm). The unsupported Vertical implant gap defect at the coronal part of the socket was 2.80 mm ± 0.83 mm for all groups in both horizontal and vertical direction. The vertical peri-implant interradicular bone support showed increased bone support with increase in implant length (L). The buccal and lingual inter-radicular bone-support was least for Length (L-8.5 mm), moderate for L-11.5 mm, and highest for L-13.5 mm groups, respectively. The mesial inter-radicular bone support was least for G4G7, moderate for G1G2G5G8, and maximum for G3G6G9 groups. Similarly, the distal inter-radicular bone support was least for G4G7, moderate for G1G5G8, and maximum for G2G3G6G9 groups, respectively. There was no apical bone support in L-8.5 mm group as the tip of implant was 3.5–4 mm within the socket tip. Whereas, L-11.5 mm had decent (0.9–1 mm) and L-13.5 mm had Good (1.35–1.95 mm) apical bone support as the implant tip was beyond the socket tip. Conclusion: All the groups showed good interradicular bone support on buccal and lingual surfaces. Regular width implants with longer length showed satisfactory interradicular bone support on mesial and distal surfaces. Longer implants showed good apical bone support in all the four surfaces and hence good apical primary stability expected.
topic bone support
gap defects
immediate molar implants
implant length and diameter
inter-radicular bone
primary stability
url http://www.jpbsonline.org/article.asp?issn=0975-7406;year=2021;volume=13;issue=5;spage=484;epage=491;aulast=Sayed
work_keys_str_mv AT arshadjamalsayed influenceofinterradicularseptalbonequantityinprimarystabilityofimmediatemolarimplantswithdifferentlengthanddiameterplacedinmandibularregionaconebeamcomputedtomographybasedsimulatedimplantstudy
AT safiashoebshaikh influenceofinterradicularseptalbonequantityinprimarystabilityofimmediatemolarimplantswithdifferentlengthanddiameterplacedinmandibularregionaconebeamcomputedtomographybasedsimulatedimplantstudy
AT shoebyakubshaikh influenceofinterradicularseptalbonequantityinprimarystabilityofimmediatemolarimplantswithdifferentlengthanddiameterplacedinmandibularregionaconebeamcomputedtomographybasedsimulatedimplantstudy
AT mohammedabidhussain influenceofinterradicularseptalbonequantityinprimarystabilityofimmediatemolarimplantswithdifferentlengthanddiameterplacedinmandibularregionaconebeamcomputedtomographybasedsimulatedimplantstudy
AT sabahatullahkhantareen influenceofinterradicularseptalbonequantityinprimarystabilityofimmediatemolarimplantswithdifferentlengthanddiameterplacedinmandibularregionaconebeamcomputedtomographybasedsimulatedimplantstudy
AT vaibhavawinashe influenceofinterradicularseptalbonequantityinprimarystabilityofimmediatemolarimplantswithdifferentlengthanddiameterplacedinmandibularregionaconebeamcomputedtomographybasedsimulatedimplantstudy
_version_ 1721377337808781312