Comparison Performance of the Elliptical Flow Condenser for a Domestic Refrigerator with Wire-on-Tube Condenser
investigation into the performance of a novel design of condenser consisted of number of loops as elliptical shape for domestic refrigeration system and comparison with wire-on-tube condenser. The purpose of this study is designing and manufacturing a new type of condensers (Elliptical condenser) t...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Al-Nahrain Journal for Engineering Sciences
2016-06-01
|
Series: | مجلة النهرين للعلوم الهندسية |
Subjects: | |
Online Access: | https://nahje.com/index.php/main/article/view/23 |
id |
doaj-85bed2c288b340df9625e159d2455b3e |
---|---|
record_format |
Article |
spelling |
doaj-85bed2c288b340df9625e159d2455b3e2021-02-02T18:02:11ZengAl-Nahrain Journal for Engineering Sciencesمجلة النهرين للعلوم الهندسية2521-91542521-91622016-06-0119223Comparison Performance of the Elliptical Flow Condenser for a Domestic Refrigerator with Wire-on-Tube CondenserDheya Ghanim Mutasher0Mechanical Eng. Dep., University of Technology investigation into the performance of a novel design of condenser consisted of number of loops as elliptical shape for domestic refrigeration system and comparison with wire-on-tube condenser. The purpose of this study is designing and manufacturing a new type of condensers (Elliptical condenser) that depends on the experimental data by heat exchanger performance under various operating conditions. The experiment was conducted with a refrigerator designed to work with HFC134a, under no load and with loads (1.5,3 and 12 litters of water). The results showed that the work done by the compressor decreases with elliptical condenser, and then the power consumption also decreases about (0.3Amp to 0.5Amp). Also, the effects of shape change of the condenser were very important in enhancement heat transfer rate and reduction the frictional loss as result of reducing the pressure drop in the condenser. Therefore, the elliptical condenser can be used instead of the wire-on-tube air cooled condenser in a domestic refrigeration system. https://nahje.com/index.php/main/article/view/23Heat TransferHousehold RefrigeratorElliptical CondenserWire-on-Tube Condenser |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dheya Ghanim Mutasher |
spellingShingle |
Dheya Ghanim Mutasher Comparison Performance of the Elliptical Flow Condenser for a Domestic Refrigerator with Wire-on-Tube Condenser مجلة النهرين للعلوم الهندسية Heat Transfer Household Refrigerator Elliptical Condenser Wire-on-Tube Condenser |
author_facet |
Dheya Ghanim Mutasher |
author_sort |
Dheya Ghanim Mutasher |
title |
Comparison Performance of the Elliptical Flow Condenser for a Domestic Refrigerator with Wire-on-Tube Condenser |
title_short |
Comparison Performance of the Elliptical Flow Condenser for a Domestic Refrigerator with Wire-on-Tube Condenser |
title_full |
Comparison Performance of the Elliptical Flow Condenser for a Domestic Refrigerator with Wire-on-Tube Condenser |
title_fullStr |
Comparison Performance of the Elliptical Flow Condenser for a Domestic Refrigerator with Wire-on-Tube Condenser |
title_full_unstemmed |
Comparison Performance of the Elliptical Flow Condenser for a Domestic Refrigerator with Wire-on-Tube Condenser |
title_sort |
comparison performance of the elliptical flow condenser for a domestic refrigerator with wire-on-tube condenser |
publisher |
Al-Nahrain Journal for Engineering Sciences |
series |
مجلة النهرين للعلوم الهندسية |
issn |
2521-9154 2521-9162 |
publishDate |
2016-06-01 |
description |
investigation into the performance of a novel design of condenser consisted of number of loops as elliptical shape for domestic refrigeration system and comparison with wire-on-tube condenser. The purpose of this study is designing and manufacturing a new type of condensers (Elliptical condenser) that depends on the experimental data by heat exchanger performance under various operating conditions. The experiment was conducted with a refrigerator designed to work with HFC134a, under no load and with loads (1.5,3 and 12 litters of water). The results showed that the work done by the compressor decreases with elliptical condenser, and then the power consumption also decreases about (0.3Amp to 0.5Amp). Also, the effects of shape change of the condenser were very important in enhancement heat transfer rate and reduction the frictional loss as result of reducing the pressure drop in the condenser. Therefore, the elliptical condenser can be used instead of the wire-on-tube air cooled condenser in a domestic refrigeration system.
|
topic |
Heat Transfer Household Refrigerator Elliptical Condenser Wire-on-Tube Condenser |
url |
https://nahje.com/index.php/main/article/view/23 |
work_keys_str_mv |
AT dheyaghanimmutasher comparisonperformanceoftheellipticalflowcondenserforadomesticrefrigeratorwithwireontubecondenser |
_version_ |
1724292380319809536 |