Heat Treatment and Ventilation Optimization in a Deep Mine

In order to address the issue of high temperatures and thermal damages in deep mines, the factors causing downhole heat damage at high temperatures were analyzed, the mine ventilation system was optimized and rebuilt, and a cooling system was established. The proposed cooling system uses mine water...

Full description

Bibliographic Details
Main Authors: Xingxin Nie, Xiaobin Wei, Xiaochen Li, Caiwu Lu
Format: Article
Language:English
Published: Hindawi Limited 2018-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2018/1529490
id doaj-858543bc99dd421493bfb6911db0bada
record_format Article
spelling doaj-858543bc99dd421493bfb6911db0bada2020-11-25T00:37:45ZengHindawi LimitedAdvances in Civil Engineering1687-80861687-80942018-01-01201810.1155/2018/15294901529490Heat Treatment and Ventilation Optimization in a Deep MineXingxin Nie0Xiaobin Wei1Xiaochen Li2Caiwu Lu3School of Management, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055, ChinaSchool of Management, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055, ChinaSchool of Management, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055, ChinaSchool of Management, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055, ChinaIn order to address the issue of high temperatures and thermal damages in deep mines, the factors causing downhole heat damage at high temperatures were analyzed, the mine ventilation system was optimized and rebuilt, and a cooling system was established. The proposed cooling system uses mine water as the cooling source, and its features are based on the analysis of traditional cooling systems. The current ventilation system in the 1118 m deep pit of the Jinqu Gold Mine was evaluated, and the ventilation network, ventilation equipment, and ventilation structures near the underground working face were optimized. The low-temperature mine water stored in the middle section of the mine at 640 m depth was used as the cooling source, and a cooling system was established near the 440 m deep middle return well to alleviate the high-temperature and high-humidity conditions of the 280 m deep middle-western area. The results show that the effective air volume in the west wing at 280 m was 3.0 m3/s, the operating ambient temperature was 27.6°C, the relative humidity was reduced to 76%, and the temperature was reduced by 5-6°C after the optimization of the system.http://dx.doi.org/10.1155/2018/1529490
collection DOAJ
language English
format Article
sources DOAJ
author Xingxin Nie
Xiaobin Wei
Xiaochen Li
Caiwu Lu
spellingShingle Xingxin Nie
Xiaobin Wei
Xiaochen Li
Caiwu Lu
Heat Treatment and Ventilation Optimization in a Deep Mine
Advances in Civil Engineering
author_facet Xingxin Nie
Xiaobin Wei
Xiaochen Li
Caiwu Lu
author_sort Xingxin Nie
title Heat Treatment and Ventilation Optimization in a Deep Mine
title_short Heat Treatment and Ventilation Optimization in a Deep Mine
title_full Heat Treatment and Ventilation Optimization in a Deep Mine
title_fullStr Heat Treatment and Ventilation Optimization in a Deep Mine
title_full_unstemmed Heat Treatment and Ventilation Optimization in a Deep Mine
title_sort heat treatment and ventilation optimization in a deep mine
publisher Hindawi Limited
series Advances in Civil Engineering
issn 1687-8086
1687-8094
publishDate 2018-01-01
description In order to address the issue of high temperatures and thermal damages in deep mines, the factors causing downhole heat damage at high temperatures were analyzed, the mine ventilation system was optimized and rebuilt, and a cooling system was established. The proposed cooling system uses mine water as the cooling source, and its features are based on the analysis of traditional cooling systems. The current ventilation system in the 1118 m deep pit of the Jinqu Gold Mine was evaluated, and the ventilation network, ventilation equipment, and ventilation structures near the underground working face were optimized. The low-temperature mine water stored in the middle section of the mine at 640 m depth was used as the cooling source, and a cooling system was established near the 440 m deep middle return well to alleviate the high-temperature and high-humidity conditions of the 280 m deep middle-western area. The results show that the effective air volume in the west wing at 280 m was 3.0 m3/s, the operating ambient temperature was 27.6°C, the relative humidity was reduced to 76%, and the temperature was reduced by 5-6°C after the optimization of the system.
url http://dx.doi.org/10.1155/2018/1529490
work_keys_str_mv AT xingxinnie heattreatmentandventilationoptimizationinadeepmine
AT xiaobinwei heattreatmentandventilationoptimizationinadeepmine
AT xiaochenli heattreatmentandventilationoptimizationinadeepmine
AT caiwulu heattreatmentandventilationoptimizationinadeepmine
_version_ 1725299700994670592