Automatic cleaning system of sample preparation of flue gas tester

It is shown a detailed description of the operation of the automatic cleaning at different modes and levels of concentration of dust and gas stream pollution of flue gas. The basis of an automatic cleaning system of dust filters before gas analyzers based on the principle of a closed system of auto...

Full description

Bibliographic Details
Main Authors: Дмитро Григорович Корнієнко, Владислав Пилипович Приміський
Format: Article
Language:English
Published: PC Technology Center 2015-01-01
Series:Tehnologìčnij Audit ta Rezervi Virobnictva
Subjects:
gas
Online Access:http://journals.uran.ua/tarp/article/view/37029
id doaj-8530b229565f4ebea8e7f29316c0467a
record_format Article
spelling doaj-8530b229565f4ebea8e7f29316c0467a2020-11-25T02:44:57ZengPC Technology CenterTehnologìčnij Audit ta Rezervi Virobnictva2226-37802312-83722015-01-0113(21)293210.15587/2312-8372.2015.3702937029Automatic cleaning system of sample preparation of flue gas testerДмитро Григорович Корнієнко0Владислав Пилипович Приміський1National Technical University of Ukraine “Kyiv Polytechnic Institute”, 37, Prospect Peremohy, 03056, Kyiv-56National Technical University of Ukraine “Kyiv Polytechnic Institute”, 37, Prospect Peremohy, 03056, Kyiv-56It is shown a detailed description of the operation of the automatic cleaning at different modes and levels of concentration of dust and gas stream pollution of flue gas. The basis of an automatic cleaning system of dust filters before gas analyzers based on the principle of a closed system of automatic control. The system constantly compares the real current flow rate with a fixed current pre-entered in the control unit. The control unit sends a signal to the switching system of solenoid valves when reducing the flow of the sample, due to contamination (clogging) of filters below a fixed level and with the help of flow booster begins to reverse blowing of dust filter from dust in the chimney. During investigation it is found that the best operation mode of system actuation is a 25-30 % decrease in the expense of the nominal value of the primary sample flow while "clean" filter. Another important feature of the system is the choice of performance and power of flow boosters for blowdown. The power of flow booster was 1,5-2,0 kW during investigations on the smokestacks of coal boilers, TPC with the dust concentration of 120-150 mg/m3 with ensuring a flow rate of smoke samples in the range of 8-10 l/min. The proposed system is simple in construction, does not require a significant investment for its implementation and provides automatic cleaning of dust filters without operator. Automatic cleaning of filter dust is recommended for stationary systems for monitoring the concentration of toxic components of flue gases for industry, energy, cement, brick and asphalt concrete plants, everywhere where the treatment and control of flue gas is carried out by gas analyzers.http://journals.uran.ua/tarp/article/view/37029filtergas analyzersamplegasvalveflow meterflowdustcleaningcontrolschedule
collection DOAJ
language English
format Article
sources DOAJ
author Дмитро Григорович Корнієнко
Владислав Пилипович Приміський
spellingShingle Дмитро Григорович Корнієнко
Владислав Пилипович Приміський
Automatic cleaning system of sample preparation of flue gas tester
Tehnologìčnij Audit ta Rezervi Virobnictva
filter
gas analyzer
sample
gas
valve
flow meter
flow
dust
cleaning
control
schedule
author_facet Дмитро Григорович Корнієнко
Владислав Пилипович Приміський
author_sort Дмитро Григорович Корнієнко
title Automatic cleaning system of sample preparation of flue gas tester
title_short Automatic cleaning system of sample preparation of flue gas tester
title_full Automatic cleaning system of sample preparation of flue gas tester
title_fullStr Automatic cleaning system of sample preparation of flue gas tester
title_full_unstemmed Automatic cleaning system of sample preparation of flue gas tester
title_sort automatic cleaning system of sample preparation of flue gas tester
publisher PC Technology Center
series Tehnologìčnij Audit ta Rezervi Virobnictva
issn 2226-3780
2312-8372
publishDate 2015-01-01
description It is shown a detailed description of the operation of the automatic cleaning at different modes and levels of concentration of dust and gas stream pollution of flue gas. The basis of an automatic cleaning system of dust filters before gas analyzers based on the principle of a closed system of automatic control. The system constantly compares the real current flow rate with a fixed current pre-entered in the control unit. The control unit sends a signal to the switching system of solenoid valves when reducing the flow of the sample, due to contamination (clogging) of filters below a fixed level and with the help of flow booster begins to reverse blowing of dust filter from dust in the chimney. During investigation it is found that the best operation mode of system actuation is a 25-30 % decrease in the expense of the nominal value of the primary sample flow while "clean" filter. Another important feature of the system is the choice of performance and power of flow boosters for blowdown. The power of flow booster was 1,5-2,0 kW during investigations on the smokestacks of coal boilers, TPC with the dust concentration of 120-150 mg/m3 with ensuring a flow rate of smoke samples in the range of 8-10 l/min. The proposed system is simple in construction, does not require a significant investment for its implementation and provides automatic cleaning of dust filters without operator. Automatic cleaning of filter dust is recommended for stationary systems for monitoring the concentration of toxic components of flue gases for industry, energy, cement, brick and asphalt concrete plants, everywhere where the treatment and control of flue gas is carried out by gas analyzers.
topic filter
gas analyzer
sample
gas
valve
flow meter
flow
dust
cleaning
control
schedule
url http://journals.uran.ua/tarp/article/view/37029
work_keys_str_mv AT dmitrogrigorovičkorníênko automaticcleaningsystemofsamplepreparationoffluegastester
AT vladislavpilipovičprimísʹkij automaticcleaningsystemofsamplepreparationoffluegastester
_version_ 1724764943008399360