Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks
Stilling basins have been used as an energy dissipater downstream of hydraulic structures. Dimensions of the stilling basins depends on hydraulic jump characteristics. In this research diverging hydraulic jump with an adverse slope using baffle blocks and an end sill have been studied experimentally...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Isfahan University of Technology
2019-12-01
|
Series: | علوم آب و خاک |
Subjects: | |
Online Access: | http://jstnar.iut.ac.ir/article-1-3780-en.html |
id |
doaj-84a60688ccc343fba018cb949c21a161 |
---|---|
record_format |
Article |
spelling |
doaj-84a60688ccc343fba018cb949c21a1612021-04-20T08:18:13ZfasIsfahan University of Technology علوم آب و خاک2476-35942476-55542019-12-01233299311Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle BlocksZ. Eshkou0A. Dehghani1A. Ahmadi2 Shahrood University of Technology 2. Department of Water Engineering, Gorgan University of Agricultural Sciences and Natural Resources, Gorgan, Iran. 1. Department of Civil Engineering, Shahrood University of Technology, Sharood, Iran. Stilling basins have been used as an energy dissipater downstream of hydraulic structures. Dimensions of the stilling basins depends on hydraulic jump characteristics. In this research diverging hydraulic jump with an adverse slope using baffle blocks and an end sill have been studied experimentally and effect of diverging angle of the walls, adverse bed slope and baffle blocks on the hydraulic jump characteristics have been evaluated. Tests have been done for rectangular stilling basin with different bed slopes (0.025-0.05-0.075) and different diverging angle (3-5-9) degree and using baffle blocks. Discharge and Froude numbers considered to range from 39 to 81.7 lit/s and 4.44 to 8.56 respectively. Results have been indicated that the baffle blocks have been reduced sequent depth ratio and relative length of the jump 12% and 18% respectively (in comparison to diverging stilling basin with adverse slope without block). It was also found that baffle blocks and end sill could considerably improve the general condition and features of an expanding hydraulic jump with an adverse slope and could stabilize the position of this type and bi-stable situation of the flow.http://jstnar.iut.ac.ir/article-1-3780-en.htmldiverging stilling basinadverse bed slopecharacteristics of hydraulic jumpbaffle blocks |
collection |
DOAJ |
language |
fas |
format |
Article |
sources |
DOAJ |
author |
Z. Eshkou A. Dehghani A. Ahmadi |
spellingShingle |
Z. Eshkou A. Dehghani A. Ahmadi Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks علوم آب و خاک diverging stilling basin adverse bed slope characteristics of hydraulic jump baffle blocks |
author_facet |
Z. Eshkou A. Dehghani A. Ahmadi |
author_sort |
Z. Eshkou |
title |
Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks |
title_short |
Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks |
title_full |
Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks |
title_fullStr |
Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks |
title_full_unstemmed |
Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks |
title_sort |
experimental investigation of the characteristics of hydraulic jump in a diverging stilling basin with an adverse slope using baffle blocks |
publisher |
Isfahan University of Technology |
series |
علوم آب و خاک |
issn |
2476-3594 2476-5554 |
publishDate |
2019-12-01 |
description |
Stilling basins have been used as an energy dissipater downstream of hydraulic structures. Dimensions of the stilling basins depends on hydraulic jump characteristics. In this research diverging hydraulic jump with an adverse slope using baffle blocks and an end sill have been studied experimentally and effect of diverging angle of the walls, adverse bed slope and baffle blocks on the hydraulic jump characteristics have been evaluated. Tests have been done for rectangular stilling basin with different bed slopes (0.025-0.05-0.075) and different diverging angle (3-5-9) degree and using baffle blocks. Discharge and Froude numbers considered to range from 39 to 81.7 lit/s and 4.44 to 8.56 respectively. Results have been indicated that the baffle blocks have been reduced sequent depth ratio and relative length of the jump 12% and 18% respectively (in comparison to diverging stilling basin with adverse slope without block). It was also found that baffle blocks and end sill could considerably improve the general condition and features of an expanding hydraulic jump with an adverse slope and could stabilize the position of this type and bi-stable situation of the flow. |
topic |
diverging stilling basin adverse bed slope characteristics of hydraulic jump baffle blocks |
url |
http://jstnar.iut.ac.ir/article-1-3780-en.html |
work_keys_str_mv |
AT zeshkou experimentalinvestigationofthecharacteristicsofhydraulicjumpinadivergingstillingbasinwithanadverseslopeusingbaffleblocks AT adehghani experimentalinvestigationofthecharacteristicsofhydraulicjumpinadivergingstillingbasinwithanadverseslopeusingbaffleblocks AT aahmadi experimentalinvestigationofthecharacteristicsofhydraulicjumpinadivergingstillingbasinwithanadverseslopeusingbaffleblocks |
_version_ |
1721518513470832640 |