Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks

Stilling basins have been used as an energy dissipater downstream of hydraulic structures. Dimensions of the stilling basins depends on hydraulic jump characteristics. In this research diverging hydraulic jump with an adverse slope using baffle blocks and an end sill have been studied experimentally...

Full description

Bibliographic Details
Main Authors: Z. Eshkou, A. Dehghani, A. Ahmadi
Format: Article
Language:fas
Published: Isfahan University of Technology 2019-12-01
Series:علوم آب و خاک
Subjects:
Online Access:http://jstnar.iut.ac.ir/article-1-3780-en.html
id doaj-84a60688ccc343fba018cb949c21a161
record_format Article
spelling doaj-84a60688ccc343fba018cb949c21a1612021-04-20T08:18:13ZfasIsfahan University of Technology علوم آب و خاک2476-35942476-55542019-12-01233299311Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle BlocksZ. Eshkou0A. Dehghani1A. Ahmadi2 Shahrood University of Technology 2. Department of Water Engineering, Gorgan University of Agricultural Sciences and Natural Resources, Gorgan, Iran. 1. Department of Civil Engineering, Shahrood University of Technology, Sharood, Iran. Stilling basins have been used as an energy dissipater downstream of hydraulic structures. Dimensions of the stilling basins depends on hydraulic jump characteristics. In this research diverging hydraulic jump with an adverse slope using baffle blocks and an end sill have been studied experimentally and effect of diverging angle of the walls, adverse bed slope and baffle blocks on the hydraulic jump characteristics have been evaluated. Tests have been done for rectangular stilling basin with different bed slopes (0.025-0.05-0.075) and different diverging angle (3-5-9) degree and using baffle blocks. Discharge and Froude numbers considered to range from 39 to 81.7 lit/s and 4.44 to 8.56 respectively. Results have been indicated that the baffle blocks have been reduced sequent depth ratio and relative length of the jump 12% and 18% respectively (in comparison to diverging stilling basin with adverse slope without block). It was also found that baffle blocks and end sill could considerably improve the general condition and features of an expanding hydraulic jump with an adverse slope and could stabilize the position of this type and bi-stable situation of the flow.http://jstnar.iut.ac.ir/article-1-3780-en.htmldiverging stilling basinadverse bed slopecharacteristics of hydraulic jumpbaffle blocks
collection DOAJ
language fas
format Article
sources DOAJ
author Z. Eshkou
A. Dehghani
A. Ahmadi
spellingShingle Z. Eshkou
A. Dehghani
A. Ahmadi
Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks
علوم آب و خاک
diverging stilling basin
adverse bed slope
characteristics of hydraulic jump
baffle blocks
author_facet Z. Eshkou
A. Dehghani
A. Ahmadi
author_sort Z. Eshkou
title Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks
title_short Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks
title_full Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks
title_fullStr Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks
title_full_unstemmed Experimental Investigation of the Characteristics of Hydraulic Jump in a Diverging Stilling Basin with an Adverse Slope Using Baffle Blocks
title_sort experimental investigation of the characteristics of hydraulic jump in a diverging stilling basin with an adverse slope using baffle blocks
publisher Isfahan University of Technology
series علوم آب و خاک
issn 2476-3594
2476-5554
publishDate 2019-12-01
description Stilling basins have been used as an energy dissipater downstream of hydraulic structures. Dimensions of the stilling basins depends on hydraulic jump characteristics. In this research diverging hydraulic jump with an adverse slope using baffle blocks and an end sill have been studied experimentally and effect of diverging angle of the walls, adverse bed slope and baffle blocks on the hydraulic jump characteristics have been evaluated. Tests have been done for rectangular stilling basin with different bed slopes (0.025-0.05-0.075) and different diverging angle (3-5-9) degree and using baffle blocks. Discharge and Froude numbers considered to range from 39 to 81.7 lit/s and 4.44 to 8.56 respectively. Results have been indicated that the baffle blocks have been reduced sequent depth ratio and relative length of the jump 12% and 18% respectively (in comparison to diverging stilling basin with adverse slope without block). It was also found that baffle blocks and end sill could considerably improve the general condition and features of an expanding hydraulic jump with an adverse slope and could stabilize the position of this type and bi-stable situation of the flow.
topic diverging stilling basin
adverse bed slope
characteristics of hydraulic jump
baffle blocks
url http://jstnar.iut.ac.ir/article-1-3780-en.html
work_keys_str_mv AT zeshkou experimentalinvestigationofthecharacteristicsofhydraulicjumpinadivergingstillingbasinwithanadverseslopeusingbaffleblocks
AT adehghani experimentalinvestigationofthecharacteristicsofhydraulicjumpinadivergingstillingbasinwithanadverseslopeusingbaffleblocks
AT aahmadi experimentalinvestigationofthecharacteristicsofhydraulicjumpinadivergingstillingbasinwithanadverseslopeusingbaffleblocks
_version_ 1721518513470832640