Reliability of Visual Field Index in Staging Glaucomatous Visual Field Damage

Introduction: Standard automated perimetry is integral to the testing of visual function in glaucoma. Classification of glaucomatous visual field defects into different severity levels is important to guide effective management; but the available classification systems may be cumbersome and impracti...

Full description

Bibliographic Details
Main Authors: Neetha Kuzhuppilly, Shilpa Patil, Shibi Dev, Aditya Deo
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2018-06-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://jcdr.net/articles/PDF/11620/34541_CE[Ra1]_F(SHU)_PF1(SH_OM)_PN(SS).pdf
id doaj-8491febf0d04457ebf9f5a83aba0b57b
record_format Article
spelling doaj-8491febf0d04457ebf9f5a83aba0b57b2020-11-25T03:01:06ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2018-06-01126NC05NC0810.7860/JCDR/2018/34541.11620Reliability of Visual Field Index in Staging Glaucomatous Visual Field DamageNeetha Kuzhuppilly0Shilpa Patil1Shibi Dev2Aditya Deo3Assistant Professor, Department of Ophthalmology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Udupi, Karnataka, India.Glaucoma Consultant, Department of Glaucoma, Aastha Superspeciality Eye Hospital, Bengaluru, Karnataka, India.Head of Department, Department of Glaucoma, Nethradhama Superspeciality Eye Hospital, Bengaluru, Karnataka, India.Consultant Ophthalmologist and Glaucoma Surgeon, Department of Ophthalmology, Eye Infirmary and Laser Centre, Nagpur, Maharashtra, India.Introduction: Standard automated perimetry is integral to the testing of visual function in glaucoma. Classification of glaucomatous visual field defects into different severity levels is important to guide effective management; but the available classification systems may be cumbersome and impractical on a daily basis. Aim: To quantify, correlate and analyse the relation between Visual Field Index (VFI) and the stages of glaucomatous field damage as defined by Hodapp Parrish Anderson (HPA). To check the validity of Glaucoma Staging Indices (GSI), which is a new glaucomatous field classification system dependent on VFI. Materials and Methods: The study was a prospective, observational analysis of consecutive visual field tests done between August 2015 and March 2016. The Institutional Ethical Committee approved the protocol, and participants who gave written informed consent were included in the study. Patients underwent a comprehensive eye examination including standard automated perimetry with Humphrey Visual Field Analyser. Data was collected from each visual field and the fields were evaluated and classified into four stages- Normal, Early defect, Moderate defect or Severe defect based on HPA classification. HPA and Geological Strength Index (GSI) classification systems were compared and analysed with Kappa analysis. Results: Analysis of 170 visual fields of 95 patients showed that VFI was significantly different between Normal, Early defect, Moderate defect and Severe defects as classified with HPA staging, p<0.001. VFI had strong positive correlation with Mean Deviation (MD), r=0.984, p<0.001 and non-linear correlation with Pattern Standard Deviation (PSD), r = -0.472, p<0.001. On comparing HPA staging with GSI, κ=0.633, p<0.001. VFI, MD and PSD in each of the severity stages across the two classification systems showed no significant differences (p>0.05). Conclusion: In established glaucoma, GSI is a good dependable staging system. It is readily available on the single field print out and can be a quick reference for decision making in the management of glaucoma patients.https://jcdr.net/articles/PDF/11620/34541_CE[Ra1]_F(SHU)_PF1(SH_OM)_PN(SS).pdfglaucoma staging indiceshumphrey field analyserglaucoma management
collection DOAJ
language English
format Article
sources DOAJ
author Neetha Kuzhuppilly
Shilpa Patil
Shibi Dev
Aditya Deo
spellingShingle Neetha Kuzhuppilly
Shilpa Patil
Shibi Dev
Aditya Deo
Reliability of Visual Field Index in Staging Glaucomatous Visual Field Damage
Journal of Clinical and Diagnostic Research
glaucoma staging indices
humphrey field analyser
glaucoma management
author_facet Neetha Kuzhuppilly
Shilpa Patil
Shibi Dev
Aditya Deo
author_sort Neetha Kuzhuppilly
title Reliability of Visual Field Index in Staging Glaucomatous Visual Field Damage
title_short Reliability of Visual Field Index in Staging Glaucomatous Visual Field Damage
title_full Reliability of Visual Field Index in Staging Glaucomatous Visual Field Damage
title_fullStr Reliability of Visual Field Index in Staging Glaucomatous Visual Field Damage
title_full_unstemmed Reliability of Visual Field Index in Staging Glaucomatous Visual Field Damage
title_sort reliability of visual field index in staging glaucomatous visual field damage
publisher JCDR Research and Publications Private Limited
series Journal of Clinical and Diagnostic Research
issn 2249-782X
0973-709X
publishDate 2018-06-01
description Introduction: Standard automated perimetry is integral to the testing of visual function in glaucoma. Classification of glaucomatous visual field defects into different severity levels is important to guide effective management; but the available classification systems may be cumbersome and impractical on a daily basis. Aim: To quantify, correlate and analyse the relation between Visual Field Index (VFI) and the stages of glaucomatous field damage as defined by Hodapp Parrish Anderson (HPA). To check the validity of Glaucoma Staging Indices (GSI), which is a new glaucomatous field classification system dependent on VFI. Materials and Methods: The study was a prospective, observational analysis of consecutive visual field tests done between August 2015 and March 2016. The Institutional Ethical Committee approved the protocol, and participants who gave written informed consent were included in the study. Patients underwent a comprehensive eye examination including standard automated perimetry with Humphrey Visual Field Analyser. Data was collected from each visual field and the fields were evaluated and classified into four stages- Normal, Early defect, Moderate defect or Severe defect based on HPA classification. HPA and Geological Strength Index (GSI) classification systems were compared and analysed with Kappa analysis. Results: Analysis of 170 visual fields of 95 patients showed that VFI was significantly different between Normal, Early defect, Moderate defect and Severe defects as classified with HPA staging, p<0.001. VFI had strong positive correlation with Mean Deviation (MD), r=0.984, p<0.001 and non-linear correlation with Pattern Standard Deviation (PSD), r = -0.472, p<0.001. On comparing HPA staging with GSI, κ=0.633, p<0.001. VFI, MD and PSD in each of the severity stages across the two classification systems showed no significant differences (p>0.05). Conclusion: In established glaucoma, GSI is a good dependable staging system. It is readily available on the single field print out and can be a quick reference for decision making in the management of glaucoma patients.
topic glaucoma staging indices
humphrey field analyser
glaucoma management
url https://jcdr.net/articles/PDF/11620/34541_CE[Ra1]_F(SHU)_PF1(SH_OM)_PN(SS).pdf
work_keys_str_mv AT neethakuzhuppilly reliabilityofvisualfieldindexinstagingglaucomatousvisualfielddamage
AT shilpapatil reliabilityofvisualfieldindexinstagingglaucomatousvisualfielddamage
AT shibidev reliabilityofvisualfieldindexinstagingglaucomatousvisualfielddamage
AT adityadeo reliabilityofvisualfieldindexinstagingglaucomatousvisualfielddamage
_version_ 1724695056185556992