Commissioning of neutron triple-axis spectrometers at HANARO
We report the status of the cold neutron triple-axis spectrometer (Cold TAS) and thermal neutron triple-axis spectrometer (Thermal TAS) installed at HANARO. Cold TAS, whose specifications are standard across the world, is in the final phase of commissioning. Proper instrument operation was confirmed...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-09-01
|
Series: | Nuclear Engineering and Technology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1738573319308241 |
id |
doaj-846d678a3bf74e9e8353248b1e987f93 |
---|---|
record_format |
Article |
spelling |
doaj-846d678a3bf74e9e8353248b1e987f932020-11-25T01:28:31ZengElsevierNuclear Engineering and Technology1738-57332020-09-0152921382150Commissioning of neutron triple-axis spectrometers at HANAROHaruhiro Hiraka0Jisung Lee1Byoungil Jeon2Baek-Seok Seong3Sangjin Cho4Quantum Beam Science Division, Korea Atomic Energy Research Institute, Daejeon, 34057, South Korea; Corresponding author.Korea Basic Science Institute, Daejeon, 34133, South KoreaIntelligent Computing Laboratory, Korea Atomic Energy Research Institute, Daejeon, 34057, South KoreaQuantum Beam Science Division, Korea Atomic Energy Research Institute, Daejeon, 34057, South KoreaQuantum Beam Science Division, Korea Atomic Energy Research Institute, Daejeon, 34057, South KoreaWe report the status of the cold neutron triple-axis spectrometer (Cold TAS) and thermal neutron triple-axis spectrometer (Thermal TAS) installed at HANARO. Cold TAS, whose specifications are standard across the world, is in the final phase of commissioning. Proper instrument operation was confirmed through a feasibility study of phonon measurements and data analyses with resolution convolution. In contrast, Thermal TAS is in the initial phase of commissioning, and improvement of the monochromator drum is now in progress from the viewpoint of radiation shielding. In addition, we report recent activities in the development of neutron basic elements, that is, film-coated Si-wafer collimators, which are promising for use in triple-axis spectroscopy, particularly in Cold TAS.http://www.sciencedirect.com/science/article/pii/S1738573319308241Neutron scatteringTriple-axis spectrometerHANARORadiation shieldNeutron collimator |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Haruhiro Hiraka Jisung Lee Byoungil Jeon Baek-Seok Seong Sangjin Cho |
spellingShingle |
Haruhiro Hiraka Jisung Lee Byoungil Jeon Baek-Seok Seong Sangjin Cho Commissioning of neutron triple-axis spectrometers at HANARO Nuclear Engineering and Technology Neutron scattering Triple-axis spectrometer HANARO Radiation shield Neutron collimator |
author_facet |
Haruhiro Hiraka Jisung Lee Byoungil Jeon Baek-Seok Seong Sangjin Cho |
author_sort |
Haruhiro Hiraka |
title |
Commissioning of neutron triple-axis spectrometers at HANARO |
title_short |
Commissioning of neutron triple-axis spectrometers at HANARO |
title_full |
Commissioning of neutron triple-axis spectrometers at HANARO |
title_fullStr |
Commissioning of neutron triple-axis spectrometers at HANARO |
title_full_unstemmed |
Commissioning of neutron triple-axis spectrometers at HANARO |
title_sort |
commissioning of neutron triple-axis spectrometers at hanaro |
publisher |
Elsevier |
series |
Nuclear Engineering and Technology |
issn |
1738-5733 |
publishDate |
2020-09-01 |
description |
We report the status of the cold neutron triple-axis spectrometer (Cold TAS) and thermal neutron triple-axis spectrometer (Thermal TAS) installed at HANARO. Cold TAS, whose specifications are standard across the world, is in the final phase of commissioning. Proper instrument operation was confirmed through a feasibility study of phonon measurements and data analyses with resolution convolution. In contrast, Thermal TAS is in the initial phase of commissioning, and improvement of the monochromator drum is now in progress from the viewpoint of radiation shielding. In addition, we report recent activities in the development of neutron basic elements, that is, film-coated Si-wafer collimators, which are promising for use in triple-axis spectroscopy, particularly in Cold TAS. |
topic |
Neutron scattering Triple-axis spectrometer HANARO Radiation shield Neutron collimator |
url |
http://www.sciencedirect.com/science/article/pii/S1738573319308241 |
work_keys_str_mv |
AT haruhirohiraka commissioningofneutrontripleaxisspectrometersathanaro AT jisunglee commissioningofneutrontripleaxisspectrometersathanaro AT byoungiljeon commissioningofneutrontripleaxisspectrometersathanaro AT baekseokseong commissioningofneutrontripleaxisspectrometersathanaro AT sangjincho commissioningofneutrontripleaxisspectrometersathanaro |
_version_ |
1725101142875045888 |