Copper Plating Corrosion Study in Certain Environments
Copper plating was performed on nickel substrate by means of the potentiostatic electrodeposition method from a sulphate electrolyte solution. The copper coatings morphology was studied by means of the optical and electronic scanning microscopy techniques. The uniform electrodeposited films have a...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Galati University Press
2012-03-01
|
Series: | The Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science |
Subjects: | |
Online Access: | https://www.gup.ugal.ro/ugaljournals/index.php/mms/article/view/2902 |
id |
doaj-840034e3d15a4f4da6cbc41f06fd7df5 |
---|---|
record_format |
Article |
spelling |
doaj-840034e3d15a4f4da6cbc41f06fd7df52021-07-02T18:31:34ZengGalati University PressThe Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science2668-47482668-47562012-03-013512902Copper Plating Corrosion Study in Certain EnvironmentsA. M. CANTARAGIU0M. D. GAVRIL (DONOSE)1D. C. VLADU (RADU)2C. GHEORGHIES3N. TIGAU4C. M. CANTARAGIU5"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania Copper plating was performed on nickel substrate by means of the potentiostatic electrodeposition method from a sulphate electrolyte solution. The copper coatings morphology was studied by means of the optical and electronic scanning microscopy techniques. The uniform electrodeposited films have a thickness of about 15 µm measured in cross-section. The corrosion behaviours of nickel substrate and copper films in different corrosive environments were studied. The corrosion study was performed by means of the linear polarisation method in four acid environments: 0.5 M H2SO4, HCl, HNO3 and glacial CH3COOH. From the recorded Tafel curves it was possible to obtain some information about the corrosion rate and the polarization resistance. In order to confirm these results, the gravimetric parameter was calculated by means of the “mass loss” method. By means of the X-ray diffraction analysis, the crystallographic structure of the specimens before and after corrosion was revealed. By means of the spectrophotometer device, the optical properties of the specimens were analysed. https://www.gup.ugal.ro/ugaljournals/index.php/mms/article/view/2902electrodepositioncopper platingcorrosionnickel substrate |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
A. M. CANTARAGIU M. D. GAVRIL (DONOSE) D. C. VLADU (RADU) C. GHEORGHIES N. TIGAU C. M. CANTARAGIU |
spellingShingle |
A. M. CANTARAGIU M. D. GAVRIL (DONOSE) D. C. VLADU (RADU) C. GHEORGHIES N. TIGAU C. M. CANTARAGIU Copper Plating Corrosion Study in Certain Environments The Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science electrodeposition copper plating corrosion nickel substrate |
author_facet |
A. M. CANTARAGIU M. D. GAVRIL (DONOSE) D. C. VLADU (RADU) C. GHEORGHIES N. TIGAU C. M. CANTARAGIU |
author_sort |
A. M. CANTARAGIU |
title |
Copper Plating Corrosion Study in Certain Environments |
title_short |
Copper Plating Corrosion Study in Certain Environments |
title_full |
Copper Plating Corrosion Study in Certain Environments |
title_fullStr |
Copper Plating Corrosion Study in Certain Environments |
title_full_unstemmed |
Copper Plating Corrosion Study in Certain Environments |
title_sort |
copper plating corrosion study in certain environments |
publisher |
Galati University Press |
series |
The Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science |
issn |
2668-4748 2668-4756 |
publishDate |
2012-03-01 |
description |
Copper plating was performed on nickel substrate by means of the potentiostatic electrodeposition method from a sulphate electrolyte solution. The copper coatings morphology was studied by means of the optical and electronic scanning microscopy techniques. The uniform electrodeposited films have a thickness of about 15 µm measured in cross-section. The corrosion behaviours of nickel substrate and copper films in different corrosive environments were studied. The corrosion study was performed by means of the linear polarisation method in four acid environments: 0.5 M H2SO4, HCl, HNO3 and glacial CH3COOH. From the recorded Tafel curves it was possible to obtain some information about the corrosion rate and the polarization resistance. In order to confirm these results, the gravimetric parameter was calculated by means of the “mass loss” method. By means of the X-ray diffraction analysis, the crystallographic structure of the specimens before and after corrosion was revealed. By means of the spectrophotometer device, the optical properties of the specimens were analysed.
|
topic |
electrodeposition copper plating corrosion nickel substrate |
url |
https://www.gup.ugal.ro/ugaljournals/index.php/mms/article/view/2902 |
work_keys_str_mv |
AT amcantaragiu copperplatingcorrosionstudyincertainenvironments AT mdgavrildonose copperplatingcorrosionstudyincertainenvironments AT dcvladuradu copperplatingcorrosionstudyincertainenvironments AT cgheorghies copperplatingcorrosionstudyincertainenvironments AT ntigau copperplatingcorrosionstudyincertainenvironments AT cmcantaragiu copperplatingcorrosionstudyincertainenvironments |
_version_ |
1721324593271013376 |