Copper Plating Corrosion Study in Certain Environments

Copper plating was performed on nickel substrate by means of the potentiostatic electrodeposition method from a sulphate electrolyte solution. The copper coatings morphology was studied by means of the optical and electronic scanning microscopy techniques. The uniform electrodeposited films have a...

Full description

Bibliographic Details
Main Authors: A. M. CANTARAGIU, M. D. GAVRIL (DONOSE), D. C. VLADU (RADU), C. GHEORGHIES, N. TIGAU, C. M. CANTARAGIU
Format: Article
Language:English
Published: Galati University Press 2012-03-01
Series:The Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science
Subjects:
Online Access:https://www.gup.ugal.ro/ugaljournals/index.php/mms/article/view/2902
id doaj-840034e3d15a4f4da6cbc41f06fd7df5
record_format Article
spelling doaj-840034e3d15a4f4da6cbc41f06fd7df52021-07-02T18:31:34ZengGalati University PressThe Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science2668-47482668-47562012-03-013512902Copper Plating Corrosion Study in Certain EnvironmentsA. M. CANTARAGIU0M. D. GAVRIL (DONOSE)1D. C. VLADU (RADU)2C. GHEORGHIES3N. TIGAU4C. M. CANTARAGIU5"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania"Dunarea de Jos" University of Galati, Romania Copper plating was performed on nickel substrate by means of the potentiostatic electrodeposition method from a sulphate electrolyte solution. The copper coatings morphology was studied by means of the optical and electronic scanning microscopy techniques. The uniform electrodeposited films have a thickness of about 15 µm measured in cross-section. The corrosion behaviours of nickel substrate and copper films in different corrosive environments were studied. The corrosion study was performed by means of the linear polarisation method in four acid environments: 0.5 M H2SO4, HCl, HNO3 and glacial CH3COOH. From the recorded Tafel curves it was possible to obtain some information about the corrosion rate and the polarization resistance. In order to confirm these results, the gravimetric parameter was calculated by means of the “mass loss” method. By means of the X-ray diffraction analysis, the crystallographic structure of the specimens before and after corrosion was revealed. By means of the spectrophotometer device, the optical properties of the specimens were analysed. https://www.gup.ugal.ro/ugaljournals/index.php/mms/article/view/2902electrodepositioncopper platingcorrosionnickel substrate
collection DOAJ
language English
format Article
sources DOAJ
author A. M. CANTARAGIU
M. D. GAVRIL (DONOSE)
D. C. VLADU (RADU)
C. GHEORGHIES
N. TIGAU
C. M. CANTARAGIU
spellingShingle A. M. CANTARAGIU
M. D. GAVRIL (DONOSE)
D. C. VLADU (RADU)
C. GHEORGHIES
N. TIGAU
C. M. CANTARAGIU
Copper Plating Corrosion Study in Certain Environments
The Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science
electrodeposition
copper plating
corrosion
nickel substrate
author_facet A. M. CANTARAGIU
M. D. GAVRIL (DONOSE)
D. C. VLADU (RADU)
C. GHEORGHIES
N. TIGAU
C. M. CANTARAGIU
author_sort A. M. CANTARAGIU
title Copper Plating Corrosion Study in Certain Environments
title_short Copper Plating Corrosion Study in Certain Environments
title_full Copper Plating Corrosion Study in Certain Environments
title_fullStr Copper Plating Corrosion Study in Certain Environments
title_full_unstemmed Copper Plating Corrosion Study in Certain Environments
title_sort copper plating corrosion study in certain environments
publisher Galati University Press
series The Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science
issn 2668-4748
2668-4756
publishDate 2012-03-01
description Copper plating was performed on nickel substrate by means of the potentiostatic electrodeposition method from a sulphate electrolyte solution. The copper coatings morphology was studied by means of the optical and electronic scanning microscopy techniques. The uniform electrodeposited films have a thickness of about 15 µm measured in cross-section. The corrosion behaviours of nickel substrate and copper films in different corrosive environments were studied. The corrosion study was performed by means of the linear polarisation method in four acid environments: 0.5 M H2SO4, HCl, HNO3 and glacial CH3COOH. From the recorded Tafel curves it was possible to obtain some information about the corrosion rate and the polarization resistance. In order to confirm these results, the gravimetric parameter was calculated by means of the “mass loss” method. By means of the X-ray diffraction analysis, the crystallographic structure of the specimens before and after corrosion was revealed. By means of the spectrophotometer device, the optical properties of the specimens were analysed.
topic electrodeposition
copper plating
corrosion
nickel substrate
url https://www.gup.ugal.ro/ugaljournals/index.php/mms/article/view/2902
work_keys_str_mv AT amcantaragiu copperplatingcorrosionstudyincertainenvironments
AT mdgavrildonose copperplatingcorrosionstudyincertainenvironments
AT dcvladuradu copperplatingcorrosionstudyincertainenvironments
AT cgheorghies copperplatingcorrosionstudyincertainenvironments
AT ntigau copperplatingcorrosionstudyincertainenvironments
AT cmcantaragiu copperplatingcorrosionstudyincertainenvironments
_version_ 1721324593271013376