The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements

Background: Ultrasonic vibrations are used to remove a cemented post from a root canal requiring endodontic retreatment. Various results have been reported from the studies that evaluated the effect of ultrasonic instruments in removing the posts cemented with resin cements. The aim of this study wa...

Full description

Bibliographic Details
Main Authors: Atiyeh Feiz, Behnaz Barekatain, Roohollah Naseri, Hossein Zarezadeh, Navid Askari, Saman Nasiri
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2013-01-01
Series:Dental Research Journal
Subjects:
Online Access:http://www.drjjournal.net/article.asp?issn=1735-3327;year=2013;volume=10;issue=6;spage=760;epage=763;aulast=Feiz
id doaj-83eb1923f86c427caee091d393d9d709
record_format Article
spelling doaj-83eb1923f86c427caee091d393d9d7092020-11-24T20:43:27ZengWolters Kluwer Medknow PublicationsDental Research Journal1735-33272008-02552013-01-0110676076310.4103/1735-3327.122472The influence of ultrasound on removal of prefabricated metal post cemented with different resin cementsAtiyeh FeizBehnaz BarekatainRoohollah NaseriHossein ZarezadehNavid AskariSaman NasiriBackground: Ultrasonic vibrations are used to remove a cemented post from a root canal requiring endodontic retreatment. Various results have been reported from the studies that evaluated the effect of ultrasonic instruments in removing the posts cemented with resin cements. The aim of this study was to evaluate the effect of ultrasonic energy on the retention of prefabricated metal post cemented with Panavia or Maxcem Elite cements. Materials and Methods: In this in vitro study, forty eight extracted single root premolars were decoronated with a diamond disc leaving a 13 mm long root and endodontically treated. The root canals were obturated by gutta-percha up to 5 mm with vertical condensation method and the 8 mm post-space was prepared to receive a no. 2 long Dentorama post. The roots were placed in an incubator for 48 h in 37΀C and 100% humidity. After mounting the teeth in acrylic blocks, posts were cemented in the root canals using Panavia F2.0 in 24 specimens and Maxcem Elite in 24 others. For half of the specimens in each subgroup, an ultrasonic device was applied for 4 min. Universal testing machine was used to measure the force needed to remove the posts with a crosshead speed of 1 mm/min until the post came out of the canal. Kruskal-Wallis test was used for statistical analysis at 5% level of significance. Results: The removal force was not significantly different among the groups (P > 0.05). Conclusion: Ultrasonic energy did not decrease the retention of posts cemented with Panavia or Maxcem Elite cements. Furthermore, it seems that there is no significant difference between removal force of self-etch (Panavia) and the self-etch self-adhesive (Maxcem Elite) resin cements.http://www.drjjournal.net/article.asp?issn=1735-3327;year=2013;volume=10;issue=6;spage=760;epage=763;aulast=FeizPost removalprefabricated metal postresin cementultrasound
collection DOAJ
language English
format Article
sources DOAJ
author Atiyeh Feiz
Behnaz Barekatain
Roohollah Naseri
Hossein Zarezadeh
Navid Askari
Saman Nasiri
spellingShingle Atiyeh Feiz
Behnaz Barekatain
Roohollah Naseri
Hossein Zarezadeh
Navid Askari
Saman Nasiri
The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements
Dental Research Journal
Post removal
prefabricated metal post
resin cement
ultrasound
author_facet Atiyeh Feiz
Behnaz Barekatain
Roohollah Naseri
Hossein Zarezadeh
Navid Askari
Saman Nasiri
author_sort Atiyeh Feiz
title The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements
title_short The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements
title_full The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements
title_fullStr The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements
title_full_unstemmed The influence of ultrasound on removal of prefabricated metal post cemented with different resin cements
title_sort influence of ultrasound on removal of prefabricated metal post cemented with different resin cements
publisher Wolters Kluwer Medknow Publications
series Dental Research Journal
issn 1735-3327
2008-0255
publishDate 2013-01-01
description Background: Ultrasonic vibrations are used to remove a cemented post from a root canal requiring endodontic retreatment. Various results have been reported from the studies that evaluated the effect of ultrasonic instruments in removing the posts cemented with resin cements. The aim of this study was to evaluate the effect of ultrasonic energy on the retention of prefabricated metal post cemented with Panavia or Maxcem Elite cements. Materials and Methods: In this in vitro study, forty eight extracted single root premolars were decoronated with a diamond disc leaving a 13 mm long root and endodontically treated. The root canals were obturated by gutta-percha up to 5 mm with vertical condensation method and the 8 mm post-space was prepared to receive a no. 2 long Dentorama post. The roots were placed in an incubator for 48 h in 37΀C and 100% humidity. After mounting the teeth in acrylic blocks, posts were cemented in the root canals using Panavia F2.0 in 24 specimens and Maxcem Elite in 24 others. For half of the specimens in each subgroup, an ultrasonic device was applied for 4 min. Universal testing machine was used to measure the force needed to remove the posts with a crosshead speed of 1 mm/min until the post came out of the canal. Kruskal-Wallis test was used for statistical analysis at 5% level of significance. Results: The removal force was not significantly different among the groups (P > 0.05). Conclusion: Ultrasonic energy did not decrease the retention of posts cemented with Panavia or Maxcem Elite cements. Furthermore, it seems that there is no significant difference between removal force of self-etch (Panavia) and the self-etch self-adhesive (Maxcem Elite) resin cements.
topic Post removal
prefabricated metal post
resin cement
ultrasound
url http://www.drjjournal.net/article.asp?issn=1735-3327;year=2013;volume=10;issue=6;spage=760;epage=763;aulast=Feiz
work_keys_str_mv AT atiyehfeiz theinfluenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT behnazbarekatain theinfluenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT roohollahnaseri theinfluenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT hosseinzarezadeh theinfluenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT navidaskari theinfluenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT samannasiri theinfluenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT atiyehfeiz influenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT behnazbarekatain influenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT roohollahnaseri influenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT hosseinzarezadeh influenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT navidaskari influenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
AT samannasiri influenceofultrasoundonremovalofprefabricatedmetalpostcementedwithdifferentresincements
_version_ 1716819939071885312