A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.

Polymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this st...

Full description

Bibliographic Details
Main Authors: Kai-Yuan Cheng, Ling-Ling Hsieh, Cheng-Ting Shih
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4871428?pdf=render
id doaj-833c1fb1db6a43c98f27f8b6824159ed
record_format Article
spelling doaj-833c1fb1db6a43c98f27f8b6824159ed2020-11-25T01:25:35ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01115e015579710.1371/journal.pone.0155797A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.Kai-Yuan ChengLing-Ling HsiehCheng-Ting ShihPolymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this study, the short-term stability within 24 h and feasibility of N-isopropylacrylamide (NIPAM) polymer gel dosimeters for use in three-dimensional dosimetry were evaluated using magnetic resonance imaging (MRI). NIPAM gels were used to measure the dose volume in a clinical case of intensity-modulated radiation therapy (IMRT). For dose readouts, MR images of irradiated NIPAM gel phantoms were acquired at 2, 5, 12, and 24 h after dose delivery. The mean standard errors of dose conversion from using dose calibration curves (DRC) were calculated. The measured dose volumes at the four time points were compared with those calculated using a treatment planning system (TPS). The mean standard errors of the dose conversion from using the DRCs were lower than 1 Gy. Mean pass rates of 2, 5, 12, and 24 h axial dose maps calculated using gamma evaluation with 3% dose difference and 3 mm distance-to-agreement criteria were 83.5% ± 0.9%, 85.9% ± 0.6%, 98.7% ± 0.3%, and 98.5% ± 0.9%, respectively. Compared with the dose volume histogram of the TPS, the absolute mean relative volume differences of the 2, 5, 12, and 24 h measured dose volumes were lower than 1% for the irradiated region with an absorbed dose higher than 2.8 Gy. It was concluded that a 12 h reaction time was sufficient to acquire accurate dose volume using the NIPAM gels with MR readouts.http://europepmc.org/articles/PMC4871428?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Kai-Yuan Cheng
Ling-Ling Hsieh
Cheng-Ting Shih
spellingShingle Kai-Yuan Cheng
Ling-Ling Hsieh
Cheng-Ting Shih
A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.
PLoS ONE
author_facet Kai-Yuan Cheng
Ling-Ling Hsieh
Cheng-Ting Shih
author_sort Kai-Yuan Cheng
title A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.
title_short A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.
title_full A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.
title_fullStr A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.
title_full_unstemmed A Comprehensive Evaluation of NIPAM Polymer Gel Dosimeters on Three Orthogonal Planes and Temporal Stability Analysis.
title_sort comprehensive evaluation of nipam polymer gel dosimeters on three orthogonal planes and temporal stability analysis.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2016-01-01
description Polymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this study, the short-term stability within 24 h and feasibility of N-isopropylacrylamide (NIPAM) polymer gel dosimeters for use in three-dimensional dosimetry were evaluated using magnetic resonance imaging (MRI). NIPAM gels were used to measure the dose volume in a clinical case of intensity-modulated radiation therapy (IMRT). For dose readouts, MR images of irradiated NIPAM gel phantoms were acquired at 2, 5, 12, and 24 h after dose delivery. The mean standard errors of dose conversion from using dose calibration curves (DRC) were calculated. The measured dose volumes at the four time points were compared with those calculated using a treatment planning system (TPS). The mean standard errors of the dose conversion from using the DRCs were lower than 1 Gy. Mean pass rates of 2, 5, 12, and 24 h axial dose maps calculated using gamma evaluation with 3% dose difference and 3 mm distance-to-agreement criteria were 83.5% ± 0.9%, 85.9% ± 0.6%, 98.7% ± 0.3%, and 98.5% ± 0.9%, respectively. Compared with the dose volume histogram of the TPS, the absolute mean relative volume differences of the 2, 5, 12, and 24 h measured dose volumes were lower than 1% for the irradiated region with an absorbed dose higher than 2.8 Gy. It was concluded that a 12 h reaction time was sufficient to acquire accurate dose volume using the NIPAM gels with MR readouts.
url http://europepmc.org/articles/PMC4871428?pdf=render
work_keys_str_mv AT kaiyuancheng acomprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT linglinghsieh acomprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT chengtingshih acomprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT kaiyuancheng comprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT linglinghsieh comprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
AT chengtingshih comprehensiveevaluationofnipampolymergeldosimetersonthreeorthogonalplanesandtemporalstabilityanalysis
_version_ 1725113165632503808