Predictive Control for Earthquake Response Mitigation of Buildings Using Semiactive Fluid Dampers

A predictive control strategy in conjunction with semiactive control algorithms is proposed for damping control of base-isolated structures employing semiactive fluid dampers when subjected to earthquake loads. The controller considers the delays resulting from the device’s dynamics and an observer...

Full description

Bibliographic Details
Main Authors: F. Oliveira, P. Morais, A. Suleman
Format: Article
Language:English
Published: Hindawi Limited 2014-01-01
Series:Shock and Vibration
Online Access:http://dx.doi.org/10.1155/2014/670683
id doaj-82e56568dbcb4f7ab79c79a8b79e93d5
record_format Article
spelling doaj-82e56568dbcb4f7ab79c79a8b79e93d52020-11-24T20:40:42ZengHindawi LimitedShock and Vibration1070-96221875-92032014-01-01201410.1155/2014/670683670683Predictive Control for Earthquake Response Mitigation of Buildings Using Semiactive Fluid DampersF. Oliveira0P. Morais1A. Suleman2Laboratório Nacional de Engenharia Civil (LNEC), Avenida do Brasil 101, 1700-066 Lisboa, PortugalLaboratório Nacional de Engenharia Civil (LNEC), Avenida do Brasil 101, 1700-066 Lisboa, PortugalDepartment of Mechanical Engineering, University of Victoria, P.O. Box 1700 STN CSC, Victoria, BC, V8W 2Y2, CanadaA predictive control strategy in conjunction with semiactive control algorithms is proposed for damping control of base-isolated structures employing semiactive fluid dampers when subjected to earthquake loads. The controller considers the delays resulting from the device’s dynamics and an observer for state estimation. Twenty artificial accelerograms were generated according to the Eurocode 8 for the Portuguese territory and considered for the numerical simulations of the base-isolated structure representative model. The results of a parametric study on a single degree of freedom model provide an indication for controller design in this type of problems. To evaluate the effectiveness of the proposed strategies, the response of a 10-storey base-isolated dual frame-wall building employing semiactive systems is compared with the original, passive solution and with an earlier proposed optimal controller for this type of problems. It is shown that a well-tuned controller could outperform the original structure, the structural system with a passive device (optimized) as well as with the semiactive optimal controller, in terms of relative displacement and absolute acceleration reductions.http://dx.doi.org/10.1155/2014/670683
collection DOAJ
language English
format Article
sources DOAJ
author F. Oliveira
P. Morais
A. Suleman
spellingShingle F. Oliveira
P. Morais
A. Suleman
Predictive Control for Earthquake Response Mitigation of Buildings Using Semiactive Fluid Dampers
Shock and Vibration
author_facet F. Oliveira
P. Morais
A. Suleman
author_sort F. Oliveira
title Predictive Control for Earthquake Response Mitigation of Buildings Using Semiactive Fluid Dampers
title_short Predictive Control for Earthquake Response Mitigation of Buildings Using Semiactive Fluid Dampers
title_full Predictive Control for Earthquake Response Mitigation of Buildings Using Semiactive Fluid Dampers
title_fullStr Predictive Control for Earthquake Response Mitigation of Buildings Using Semiactive Fluid Dampers
title_full_unstemmed Predictive Control for Earthquake Response Mitigation of Buildings Using Semiactive Fluid Dampers
title_sort predictive control for earthquake response mitigation of buildings using semiactive fluid dampers
publisher Hindawi Limited
series Shock and Vibration
issn 1070-9622
1875-9203
publishDate 2014-01-01
description A predictive control strategy in conjunction with semiactive control algorithms is proposed for damping control of base-isolated structures employing semiactive fluid dampers when subjected to earthquake loads. The controller considers the delays resulting from the device’s dynamics and an observer for state estimation. Twenty artificial accelerograms were generated according to the Eurocode 8 for the Portuguese territory and considered for the numerical simulations of the base-isolated structure representative model. The results of a parametric study on a single degree of freedom model provide an indication for controller design in this type of problems. To evaluate the effectiveness of the proposed strategies, the response of a 10-storey base-isolated dual frame-wall building employing semiactive systems is compared with the original, passive solution and with an earlier proposed optimal controller for this type of problems. It is shown that a well-tuned controller could outperform the original structure, the structural system with a passive device (optimized) as well as with the semiactive optimal controller, in terms of relative displacement and absolute acceleration reductions.
url http://dx.doi.org/10.1155/2014/670683
work_keys_str_mv AT foliveira predictivecontrolforearthquakeresponsemitigationofbuildingsusingsemiactivefluiddampers
AT pmorais predictivecontrolforearthquakeresponsemitigationofbuildingsusingsemiactivefluiddampers
AT asuleman predictivecontrolforearthquakeresponsemitigationofbuildingsusingsemiactivefluiddampers
_version_ 1716825944022319104