Study of the influence of the operational parameters on the photoelectro-Fenton performance of an industrial wastewater treatment prototype using Orange II as a model pollutant
A two-stage photoelectro-Fenton reactor was built and employed to test its ability to remove colour using Orange II as a model dye compound. A set of four critical operational variables was defined for the reactor under study. In order to quantify their significance on colour removal, a 24 experimen...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2017-01-01
|
Series: | Sustainable Environment Research |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2468203916301297 |
id |
doaj-82d6254f74814b2986971f4ebf41d09c |
---|---|
record_format |
Article |
spelling |
doaj-82d6254f74814b2986971f4ebf41d09c2020-11-25T02:11:56ZengBMCSustainable Environment Research2468-20392017-01-01271243110.1016/j.serj.2016.08.004Study of the influence of the operational parameters on the photoelectro-Fenton performance of an industrial wastewater treatment prototype using Orange II as a model pollutantIrma Robles0Francisco J. Rodríguez-Valadez1Eduardo Castaño2Luis A. Godínez3Center for Electrochemical Science and Technology (CIDETEQ), Pedro Escobedo, Querétaro 76703, MexicoCenter for Electrochemical Science and Technology (CIDETEQ), Pedro Escobedo, Querétaro 76703, MexicoChemistry Department, Universidad Autónoma de Querétaro, Querétaro 23847, MexicoCenter for Electrochemical Science and Technology (CIDETEQ), Pedro Escobedo, Querétaro 76703, MexicoA two-stage photoelectro-Fenton reactor was built and employed to test its ability to remove colour using Orange II as a model dye compound. A set of four critical operational variables was defined for the reactor under study. In order to quantify their significance on colour removal, a 24 experimental factorial design was used. From the resultant data, and from a variable interaction analysis, a model of the reactor's performance as well as a characteristic set of experimental conditions was obtained. From this information, a triple interaction among current density, resin concentration and pH was statistically significant. Hydraulic retention time was not important. The best treatment among those studied was obtained at pH 3, current density 23.9 mA cm−2, and 3.7 g L−1 of resin concentration, with 96% decolorization. The best results with decolorization higher than 86% were obtained at acidic or slightly acidic pH, and higher levels of current density and resin concentration, or lower level of current density and resin concentration.http://www.sciencedirect.com/science/article/pii/S2468203916301297Water treatmentPhotoelectro-FentonOrange-IIIndustrial prototypeAdvanced oxidation processes |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Irma Robles Francisco J. Rodríguez-Valadez Eduardo Castaño Luis A. Godínez |
spellingShingle |
Irma Robles Francisco J. Rodríguez-Valadez Eduardo Castaño Luis A. Godínez Study of the influence of the operational parameters on the photoelectro-Fenton performance of an industrial wastewater treatment prototype using Orange II as a model pollutant Sustainable Environment Research Water treatment Photoelectro-Fenton Orange-II Industrial prototype Advanced oxidation processes |
author_facet |
Irma Robles Francisco J. Rodríguez-Valadez Eduardo Castaño Luis A. Godínez |
author_sort |
Irma Robles |
title |
Study of the influence of the operational parameters on the photoelectro-Fenton performance of an industrial wastewater treatment prototype using Orange II as a model pollutant |
title_short |
Study of the influence of the operational parameters on the photoelectro-Fenton performance of an industrial wastewater treatment prototype using Orange II as a model pollutant |
title_full |
Study of the influence of the operational parameters on the photoelectro-Fenton performance of an industrial wastewater treatment prototype using Orange II as a model pollutant |
title_fullStr |
Study of the influence of the operational parameters on the photoelectro-Fenton performance of an industrial wastewater treatment prototype using Orange II as a model pollutant |
title_full_unstemmed |
Study of the influence of the operational parameters on the photoelectro-Fenton performance of an industrial wastewater treatment prototype using Orange II as a model pollutant |
title_sort |
study of the influence of the operational parameters on the photoelectro-fenton performance of an industrial wastewater treatment prototype using orange ii as a model pollutant |
publisher |
BMC |
series |
Sustainable Environment Research |
issn |
2468-2039 |
publishDate |
2017-01-01 |
description |
A two-stage photoelectro-Fenton reactor was built and employed to test its ability to remove colour using Orange II as a model dye compound. A set of four critical operational variables was defined for the reactor under study. In order to quantify their significance on colour removal, a 24 experimental factorial design was used. From the resultant data, and from a variable interaction analysis, a model of the reactor's performance as well as a characteristic set of experimental conditions was obtained. From this information, a triple interaction among current density, resin concentration and pH was statistically significant. Hydraulic retention time was not important. The best treatment among those studied was obtained at pH 3, current density 23.9 mA cm−2, and 3.7 g L−1 of resin concentration, with 96% decolorization. The best results with decolorization higher than 86% were obtained at acidic or slightly acidic pH, and higher levels of current density and resin concentration, or lower level of current density and resin concentration. |
topic |
Water treatment Photoelectro-Fenton Orange-II Industrial prototype Advanced oxidation processes |
url |
http://www.sciencedirect.com/science/article/pii/S2468203916301297 |
work_keys_str_mv |
AT irmarobles studyoftheinfluenceoftheoperationalparametersonthephotoelectrofentonperformanceofanindustrialwastewatertreatmentprototypeusingorangeiiasamodelpollutant AT franciscojrodriguezvaladez studyoftheinfluenceoftheoperationalparametersonthephotoelectrofentonperformanceofanindustrialwastewatertreatmentprototypeusingorangeiiasamodelpollutant AT eduardocastano studyoftheinfluenceoftheoperationalparametersonthephotoelectrofentonperformanceofanindustrialwastewatertreatmentprototypeusingorangeiiasamodelpollutant AT luisagodinez studyoftheinfluenceoftheoperationalparametersonthephotoelectrofentonperformanceofanindustrialwastewatertreatmentprototypeusingorangeiiasamodelpollutant |
_version_ |
1724911813593661440 |