Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling
Yoshihiro Yonekawa, Ashkan M Abbey, Ankoor R Shah, Benjamin J Thomas, Antonio Capone Jr Associated Retinal Consultants, Department of Ophthalmology, William Beaumont Hospital, Royal Oak, MI, USA Abstract: Phototoxic maculopathy caused by endoillumination during macular surgery is uncommon. Previo...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dove Medical Press
2014-12-01
|
Series: | Clinical Ophthalmology |
Online Access: | http://www.dovepress.com/endoilluminator-phototoxic-maculopathy-associated-with-combined-icg-as-peer-reviewed-article-OPTH |
id |
doaj-82bfc29e1d59403fbdd964ad9ae41624 |
---|---|
record_format |
Article |
spelling |
doaj-82bfc29e1d59403fbdd964ad9ae416242020-11-24T22:44:27ZengDove Medical PressClinical Ophthalmology1177-54832014-12-012014default2501250619477Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peelingYonekawa YAbbey AMShah ARThomas BJCapone Jr A Yoshihiro Yonekawa, Ashkan M Abbey, Ankoor R Shah, Benjamin J Thomas, Antonio Capone Jr Associated Retinal Consultants, Department of Ophthalmology, William Beaumont Hospital, Royal Oak, MI, USA Abstract: Phototoxic maculopathy caused by endoillumination during macular surgery is uncommon. Previously identified risk factors have included intensity of the light source, proximity to the retinal surface, and length of exposure. In the era of indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling, the use of ICG, and the technique of ILM peeling may both contribute to subsequent phototoxic maculopathy. We present cases of routine chromovitrectomy who developed phototoxic maculopathy in the precise discrete distribution of the ILM rhexes, and discuss potential mechanisms and implications. Keywords: ILM peeling, indocyanine green, vitrectomy, ERMhttp://www.dovepress.com/endoilluminator-phototoxic-maculopathy-associated-with-combined-icg-as-peer-reviewed-article-OPTH |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Yonekawa Y Abbey AM Shah AR Thomas BJ Capone Jr A |
spellingShingle |
Yonekawa Y Abbey AM Shah AR Thomas BJ Capone Jr A Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling Clinical Ophthalmology |
author_facet |
Yonekawa Y Abbey AM Shah AR Thomas BJ Capone Jr A |
author_sort |
Yonekawa Y |
title |
Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling |
title_short |
Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling |
title_full |
Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling |
title_fullStr |
Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling |
title_full_unstemmed |
Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling |
title_sort |
endoilluminator phototoxic maculopathy associated with combined icg-assisted epiretinal membrane and internal limiting membrane peeling |
publisher |
Dove Medical Press |
series |
Clinical Ophthalmology |
issn |
1177-5483 |
publishDate |
2014-12-01 |
description |
Yoshihiro Yonekawa, Ashkan M Abbey, Ankoor R Shah, Benjamin J Thomas, Antonio Capone Jr Associated Retinal Consultants, Department of Ophthalmology, William Beaumont Hospital, Royal Oak, MI, USA Abstract: Phototoxic maculopathy caused by endoillumination during macular surgery is uncommon. Previously identified risk factors have included intensity of the light source, proximity to the retinal surface, and length of exposure. In the era of indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling, the use of ICG, and the technique of ILM peeling may both contribute to subsequent phototoxic maculopathy. We present cases of routine chromovitrectomy who developed phototoxic maculopathy in the precise discrete distribution of the ILM rhexes, and discuss potential mechanisms and implications. Keywords: ILM peeling, indocyanine green, vitrectomy, ERM |
url |
http://www.dovepress.com/endoilluminator-phototoxic-maculopathy-associated-with-combined-icg-as-peer-reviewed-article-OPTH |
work_keys_str_mv |
AT yonekaway endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling AT abbeyam endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling AT shahar endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling AT thomasbj endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling AT caponejra endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling |
_version_ |
1725691755634884608 |