Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling

Yoshihiro Yonekawa, Ashkan M Abbey, Ankoor R Shah, Benjamin J Thomas, Antonio Capone Jr Associated Retinal Consultants, Department of Ophthalmology, William Beaumont Hospital, Royal Oak, MI, USA Abstract: Phototoxic maculopathy caused by endoillumination during macular surgery is uncommon. Previo...

Full description

Bibliographic Details
Main Authors: Yonekawa Y, Abbey AM, Shah AR, Thomas BJ, Capone Jr A
Format: Article
Language:English
Published: Dove Medical Press 2014-12-01
Series:Clinical Ophthalmology
Online Access:http://www.dovepress.com/endoilluminator-phototoxic-maculopathy-associated-with-combined-icg-as-peer-reviewed-article-OPTH
id doaj-82bfc29e1d59403fbdd964ad9ae41624
record_format Article
spelling doaj-82bfc29e1d59403fbdd964ad9ae416242020-11-24T22:44:27ZengDove Medical PressClinical Ophthalmology1177-54832014-12-012014default2501250619477Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peelingYonekawa YAbbey AMShah ARThomas BJCapone Jr A Yoshihiro Yonekawa, Ashkan M Abbey, Ankoor R Shah, Benjamin J Thomas, Antonio Capone Jr Associated Retinal Consultants, Department of Ophthalmology, William Beaumont Hospital, Royal Oak, MI, USA Abstract: Phototoxic maculopathy caused by endoillumination during macular surgery is uncommon. Previously identified risk factors have included intensity of the light source, proximity to the retinal surface, and length of exposure. In the era of indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling, the use of ICG, and the technique of ILM peeling may both contribute to subsequent phototoxic maculopathy. We present cases of routine chromovitrectomy who developed phototoxic maculopathy in the precise discrete distribution of the ILM rhexes, and discuss potential mechanisms and implications. Keywords: ILM peeling, indocyanine green, vitrectomy, ERMhttp://www.dovepress.com/endoilluminator-phototoxic-maculopathy-associated-with-combined-icg-as-peer-reviewed-article-OPTH
collection DOAJ
language English
format Article
sources DOAJ
author Yonekawa Y
Abbey AM
Shah AR
Thomas BJ
Capone Jr A
spellingShingle Yonekawa Y
Abbey AM
Shah AR
Thomas BJ
Capone Jr A
Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling
Clinical Ophthalmology
author_facet Yonekawa Y
Abbey AM
Shah AR
Thomas BJ
Capone Jr A
author_sort Yonekawa Y
title Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling
title_short Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling
title_full Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling
title_fullStr Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling
title_full_unstemmed Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling
title_sort endoilluminator phototoxic maculopathy associated with combined icg-assisted epiretinal membrane and internal limiting membrane peeling
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5483
publishDate 2014-12-01
description Yoshihiro Yonekawa, Ashkan M Abbey, Ankoor R Shah, Benjamin J Thomas, Antonio Capone Jr Associated Retinal Consultants, Department of Ophthalmology, William Beaumont Hospital, Royal Oak, MI, USA Abstract: Phototoxic maculopathy caused by endoillumination during macular surgery is uncommon. Previously identified risk factors have included intensity of the light source, proximity to the retinal surface, and length of exposure. In the era of indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling, the use of ICG, and the technique of ILM peeling may both contribute to subsequent phototoxic maculopathy. We present cases of routine chromovitrectomy who developed phototoxic maculopathy in the precise discrete distribution of the ILM rhexes, and discuss potential mechanisms and implications. Keywords: ILM peeling, indocyanine green, vitrectomy, ERM
url http://www.dovepress.com/endoilluminator-phototoxic-maculopathy-associated-with-combined-icg-as-peer-reviewed-article-OPTH
work_keys_str_mv AT yonekaway endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling
AT abbeyam endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling
AT shahar endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling
AT thomasbj endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling
AT caponejra endoilluminatorphototoxicmaculopathyassociatedwithcombinedicgassistedepiretinalmembraneandinternallimitingmembranepeeling
_version_ 1725691755634884608