Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems

This study aimed to compare the dynamics of air temperature and velocity under two different ventilation and housing systems during summer and winter in Korea. The NH3 concentration of both housing systems was also investigated in relation to the pig’s growth. The ventilation systems used were; nega...

Full description

Bibliographic Details
Main Authors: J. I. Song, K.-H. Park, J. H. Jeon, H. L. Choi, A. J. Barroga
Format: Article
Language:English
Published: Asian-Australasian Association of Animal Production Societies 2013-03-01
Series:Asian-Australasian Journal of Animal Sciences
Subjects:
Online Access:http://www.ajas.info/upload/pdf/ajas-26-3-433-17.pdf
id doaj-8192af08994947dfaf8bfc569116810f
record_format Article
spelling doaj-8192af08994947dfaf8bfc569116810f2020-11-24T22:58:48ZengAsian-Australasian Association of Animal Production SocietiesAsian-Australasian Journal of Animal Sciences1011-23671976-55172013-03-0126343344210.5713/ajas.2011.115154666Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing SystemsJ. I. SongK.-H. ParkJ. H. JeonH. L. ChoiA. J. BarrogaThis study aimed to compare the dynamics of air temperature and velocity under two different ventilation and housing systems during summer and winter in Korea. The NH3 concentration of both housing systems was also investigated in relation to the pig’s growth. The ventilation systems used were; negative pressure type for the enclosed pig house (EPH) and natural airflow for the conventional pig house (CPH). Against a highly fluctuating outdoor temperature, the EPH was able to maintain a stable temperature at 24.8 to 29.1°C during summer and 17.9 to 23.1°C during winter whilst the CPH had a wider temperature variance during summer at 24.7 to 32.3°C. However, the temperature fluctuation of the CPH during winter was almost the same with that of EPH at 14.5 to 18.2°C. The NH3 levels in the CPH ranged from 9.31 to 16.9 mg/L during summer and 5.1 to 19.7 mg/L during winter whilst that of the EPH pig house was 7.9 to 16.1 mg/L and 3.7 to 9.6 mg/L during summer and winter, respectively. These values were less than the critical ammonia level for pigs with the EPH maintaining a lower level than the CPH in both winter and summer. The air velocity at pig nose level in the EPH during summer was 0.23 m/s, enough to provide comfort because of the unique design of the inlet feature. However, no air movement was observed in almost all the lower portions of the CPH during winter because of the absence of an inlet feature. There was a significant improvement in weight gain and feed intake of pigs reared in the EPH compared to the CPH (p<0.05). These findings proved that despite the difference in the housing systems, a stable indoor temperature was necessary to minimize the impact of an avoidable and highly fluctuating outdoor temperature. The EPH consistently maintained an effective indoor airspeed irrespective of season; however the CPH had defective and stagnant air at pig nose level during winter. Characteristics of airflow direction and pattern were consistent relative to housing system during both summer and winter but not of airspeed. The ideal air velocity measurement favored the EPH and therefore can be appropriate for the Korean environment. Further emphasis on its cost effectiveness will be the subject of future investigations.http://www.ajas.info/upload/pdf/ajas-26-3-433-17.pdfConventional Pig HousingEnclosed Pig HousingAmmoniaHydrogen SulfideAir Velocity
collection DOAJ
language English
format Article
sources DOAJ
author J. I. Song
K.-H. Park
J. H. Jeon
H. L. Choi
A. J. Barroga
spellingShingle J. I. Song
K.-H. Park
J. H. Jeon
H. L. Choi
A. J. Barroga
Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems
Asian-Australasian Journal of Animal Sciences
Conventional Pig Housing
Enclosed Pig Housing
Ammonia
Hydrogen Sulfide
Air Velocity
author_facet J. I. Song
K.-H. Park
J. H. Jeon
H. L. Choi
A. J. Barroga
author_sort J. I. Song
title Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems
title_short Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems
title_full Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems
title_fullStr Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems
title_full_unstemmed Dynamics of Air Temperature, Velocity and Ammonia Emissions in Enclosed and Conventional Pig Housing Systems
title_sort dynamics of air temperature, velocity and ammonia emissions in enclosed and conventional pig housing systems
publisher Asian-Australasian Association of Animal Production Societies
series Asian-Australasian Journal of Animal Sciences
issn 1011-2367
1976-5517
publishDate 2013-03-01
description This study aimed to compare the dynamics of air temperature and velocity under two different ventilation and housing systems during summer and winter in Korea. The NH3 concentration of both housing systems was also investigated in relation to the pig’s growth. The ventilation systems used were; negative pressure type for the enclosed pig house (EPH) and natural airflow for the conventional pig house (CPH). Against a highly fluctuating outdoor temperature, the EPH was able to maintain a stable temperature at 24.8 to 29.1°C during summer and 17.9 to 23.1°C during winter whilst the CPH had a wider temperature variance during summer at 24.7 to 32.3°C. However, the temperature fluctuation of the CPH during winter was almost the same with that of EPH at 14.5 to 18.2°C. The NH3 levels in the CPH ranged from 9.31 to 16.9 mg/L during summer and 5.1 to 19.7 mg/L during winter whilst that of the EPH pig house was 7.9 to 16.1 mg/L and 3.7 to 9.6 mg/L during summer and winter, respectively. These values were less than the critical ammonia level for pigs with the EPH maintaining a lower level than the CPH in both winter and summer. The air velocity at pig nose level in the EPH during summer was 0.23 m/s, enough to provide comfort because of the unique design of the inlet feature. However, no air movement was observed in almost all the lower portions of the CPH during winter because of the absence of an inlet feature. There was a significant improvement in weight gain and feed intake of pigs reared in the EPH compared to the CPH (p<0.05). These findings proved that despite the difference in the housing systems, a stable indoor temperature was necessary to minimize the impact of an avoidable and highly fluctuating outdoor temperature. The EPH consistently maintained an effective indoor airspeed irrespective of season; however the CPH had defective and stagnant air at pig nose level during winter. Characteristics of airflow direction and pattern were consistent relative to housing system during both summer and winter but not of airspeed. The ideal air velocity measurement favored the EPH and therefore can be appropriate for the Korean environment. Further emphasis on its cost effectiveness will be the subject of future investigations.
topic Conventional Pig Housing
Enclosed Pig Housing
Ammonia
Hydrogen Sulfide
Air Velocity
url http://www.ajas.info/upload/pdf/ajas-26-3-433-17.pdf
work_keys_str_mv AT jisong dynamicsofairtemperaturevelocityandammoniaemissionsinenclosedandconventionalpighousingsystems
AT khpark dynamicsofairtemperaturevelocityandammoniaemissionsinenclosedandconventionalpighousingsystems
AT jhjeon dynamicsofairtemperaturevelocityandammoniaemissionsinenclosedandconventionalpighousingsystems
AT hlchoi dynamicsofairtemperaturevelocityandammoniaemissionsinenclosedandconventionalpighousingsystems
AT ajbarroga dynamicsofairtemperaturevelocityandammoniaemissionsinenclosedandconventionalpighousingsystems
_version_ 1725646435900194816