Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone

Background. Utilization of the widely used wearable sensor and smartphone technology for remote monitoring represents a healthcare breakthrough. This study aims to design a remote real-time monitoring system for multiple physiological parameters (electrocardiogram, heart rate, respiratory rate, bloo...

Full description

Bibliographic Details
Main Authors: Noman Q. Al-Naggar, Husam Mohammed Al-Hammadi, Adel Mohammed Al-Fusail, Zakarya Ali AL-Shaebi
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:Journal of Healthcare Engineering
Online Access:http://dx.doi.org/10.1155/2019/5674673
id doaj-8169bdcce84b483eba56c7c28fccb62b
record_format Article
spelling doaj-8169bdcce84b483eba56c7c28fccb62b2020-11-25T01:27:34ZengHindawi LimitedJournal of Healthcare Engineering2040-22952040-23092019-01-01201910.1155/2019/56746735674673Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on SmartphoneNoman Q. Al-Naggar0Husam Mohammed Al-Hammadi1Adel Mohammed Al-Fusail2Zakarya Ali AL-Shaebi3Department of Biomedical Engineering at Faculty of Engineering, University of Science and Technology, Sana’a, YemenDepartment of Biomedical Engineering at Faculty of Engineering, University of Science and Technology, Sana’a, YemenDepartment of Biomedical Engineering at Faculty of Engineering, University of Science and Technology, Sana’a, YemenDepartment of Biomedical Engineering at Faculty of Engineering, University of Science and Technology, Sana’a, YemenBackground. Utilization of the widely used wearable sensor and smartphone technology for remote monitoring represents a healthcare breakthrough. This study aims to design a remote real-time monitoring system for multiple physiological parameters (electrocardiogram, heart rate, respiratory rate, blood oxygen saturation, and temperature) based on smartphones, considering high performance, autoalarm generation, warning transmission, and security through more than one method. Methods. Data on monitoring parameters were acquired by the integrated circuits of wearable sensors and collected by an Arduino Mega 250 R3. The collected data were transmitted via a Wi-Fi interface to a smartphone. A patient application was developed to analyze, process, and display the data in numerical and graphical forms. The abnormality threshold values of parameters were identified and analyzed to generate an autoalarm in the system and transmitted with data to a doctor application via a third-generation (3G) mobile network and Wi-Fi. The performance of the proposed system was verified and evaluated. The proposed system was designed to meet main (sensing, processing, displaying, real-time transmission, autoalarm generation, and threshold value identification) and auxiliary requirements (compatibility, comfort, low power consumption and cost, small size, and suitability for ambulatory applications). Results. System performance is reliable, with a sufficient average accuracy measurement (99.26%). The system demonstrates an average time delay of 14 s in transmitting data to a doctor application via Wi-Fi compared with an average time of 68 s via a 3G mobile network. The proposed system achieves low power consumption against time (4 h 21 m 30 s) and the main and auxiliary requirements for remotely monitoring multiple parameters simultaneously with secure data. Conclusions. The proposed system can offer economic benefits for remotely monitoring patients living alone or in rural areas, thereby improving medical services, if manufactured in large quantities.http://dx.doi.org/10.1155/2019/5674673
collection DOAJ
language English
format Article
sources DOAJ
author Noman Q. Al-Naggar
Husam Mohammed Al-Hammadi
Adel Mohammed Al-Fusail
Zakarya Ali AL-Shaebi
spellingShingle Noman Q. Al-Naggar
Husam Mohammed Al-Hammadi
Adel Mohammed Al-Fusail
Zakarya Ali AL-Shaebi
Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone
Journal of Healthcare Engineering
author_facet Noman Q. Al-Naggar
Husam Mohammed Al-Hammadi
Adel Mohammed Al-Fusail
Zakarya Ali AL-Shaebi
author_sort Noman Q. Al-Naggar
title Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone
title_short Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone
title_full Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone
title_fullStr Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone
title_full_unstemmed Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone
title_sort design of a remote real-time monitoring system for multiple physiological parameters based on smartphone
publisher Hindawi Limited
series Journal of Healthcare Engineering
issn 2040-2295
2040-2309
publishDate 2019-01-01
description Background. Utilization of the widely used wearable sensor and smartphone technology for remote monitoring represents a healthcare breakthrough. This study aims to design a remote real-time monitoring system for multiple physiological parameters (electrocardiogram, heart rate, respiratory rate, blood oxygen saturation, and temperature) based on smartphones, considering high performance, autoalarm generation, warning transmission, and security through more than one method. Methods. Data on monitoring parameters were acquired by the integrated circuits of wearable sensors and collected by an Arduino Mega 250 R3. The collected data were transmitted via a Wi-Fi interface to a smartphone. A patient application was developed to analyze, process, and display the data in numerical and graphical forms. The abnormality threshold values of parameters were identified and analyzed to generate an autoalarm in the system and transmitted with data to a doctor application via a third-generation (3G) mobile network and Wi-Fi. The performance of the proposed system was verified and evaluated. The proposed system was designed to meet main (sensing, processing, displaying, real-time transmission, autoalarm generation, and threshold value identification) and auxiliary requirements (compatibility, comfort, low power consumption and cost, small size, and suitability for ambulatory applications). Results. System performance is reliable, with a sufficient average accuracy measurement (99.26%). The system demonstrates an average time delay of 14 s in transmitting data to a doctor application via Wi-Fi compared with an average time of 68 s via a 3G mobile network. The proposed system achieves low power consumption against time (4 h 21 m 30 s) and the main and auxiliary requirements for remotely monitoring multiple parameters simultaneously with secure data. Conclusions. The proposed system can offer economic benefits for remotely monitoring patients living alone or in rural areas, thereby improving medical services, if manufactured in large quantities.
url http://dx.doi.org/10.1155/2019/5674673
work_keys_str_mv AT nomanqalnaggar designofaremoterealtimemonitoringsystemformultiplephysiologicalparametersbasedonsmartphone
AT husammohammedalhammadi designofaremoterealtimemonitoringsystemformultiplephysiologicalparametersbasedonsmartphone
AT adelmohammedalfusail designofaremoterealtimemonitoringsystemformultiplephysiologicalparametersbasedonsmartphone
AT zakaryaalialshaebi designofaremoterealtimemonitoringsystemformultiplephysiologicalparametersbasedonsmartphone
_version_ 1725104618966351872