Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone
Background. Utilization of the widely used wearable sensor and smartphone technology for remote monitoring represents a healthcare breakthrough. This study aims to design a remote real-time monitoring system for multiple physiological parameters (electrocardiogram, heart rate, respiratory rate, bloo...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2019-01-01
|
Series: | Journal of Healthcare Engineering |
Online Access: | http://dx.doi.org/10.1155/2019/5674673 |
id |
doaj-8169bdcce84b483eba56c7c28fccb62b |
---|---|
record_format |
Article |
spelling |
doaj-8169bdcce84b483eba56c7c28fccb62b2020-11-25T01:27:34ZengHindawi LimitedJournal of Healthcare Engineering2040-22952040-23092019-01-01201910.1155/2019/56746735674673Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on SmartphoneNoman Q. Al-Naggar0Husam Mohammed Al-Hammadi1Adel Mohammed Al-Fusail2Zakarya Ali AL-Shaebi3Department of Biomedical Engineering at Faculty of Engineering, University of Science and Technology, Sana’a, YemenDepartment of Biomedical Engineering at Faculty of Engineering, University of Science and Technology, Sana’a, YemenDepartment of Biomedical Engineering at Faculty of Engineering, University of Science and Technology, Sana’a, YemenDepartment of Biomedical Engineering at Faculty of Engineering, University of Science and Technology, Sana’a, YemenBackground. Utilization of the widely used wearable sensor and smartphone technology for remote monitoring represents a healthcare breakthrough. This study aims to design a remote real-time monitoring system for multiple physiological parameters (electrocardiogram, heart rate, respiratory rate, blood oxygen saturation, and temperature) based on smartphones, considering high performance, autoalarm generation, warning transmission, and security through more than one method. Methods. Data on monitoring parameters were acquired by the integrated circuits of wearable sensors and collected by an Arduino Mega 250 R3. The collected data were transmitted via a Wi-Fi interface to a smartphone. A patient application was developed to analyze, process, and display the data in numerical and graphical forms. The abnormality threshold values of parameters were identified and analyzed to generate an autoalarm in the system and transmitted with data to a doctor application via a third-generation (3G) mobile network and Wi-Fi. The performance of the proposed system was verified and evaluated. The proposed system was designed to meet main (sensing, processing, displaying, real-time transmission, autoalarm generation, and threshold value identification) and auxiliary requirements (compatibility, comfort, low power consumption and cost, small size, and suitability for ambulatory applications). Results. System performance is reliable, with a sufficient average accuracy measurement (99.26%). The system demonstrates an average time delay of 14 s in transmitting data to a doctor application via Wi-Fi compared with an average time of 68 s via a 3G mobile network. The proposed system achieves low power consumption against time (4 h 21 m 30 s) and the main and auxiliary requirements for remotely monitoring multiple parameters simultaneously with secure data. Conclusions. The proposed system can offer economic benefits for remotely monitoring patients living alone or in rural areas, thereby improving medical services, if manufactured in large quantities.http://dx.doi.org/10.1155/2019/5674673 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Noman Q. Al-Naggar Husam Mohammed Al-Hammadi Adel Mohammed Al-Fusail Zakarya Ali AL-Shaebi |
spellingShingle |
Noman Q. Al-Naggar Husam Mohammed Al-Hammadi Adel Mohammed Al-Fusail Zakarya Ali AL-Shaebi Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone Journal of Healthcare Engineering |
author_facet |
Noman Q. Al-Naggar Husam Mohammed Al-Hammadi Adel Mohammed Al-Fusail Zakarya Ali AL-Shaebi |
author_sort |
Noman Q. Al-Naggar |
title |
Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone |
title_short |
Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone |
title_full |
Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone |
title_fullStr |
Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone |
title_full_unstemmed |
Design of a Remote Real-Time Monitoring System for Multiple Physiological Parameters Based on Smartphone |
title_sort |
design of a remote real-time monitoring system for multiple physiological parameters based on smartphone |
publisher |
Hindawi Limited |
series |
Journal of Healthcare Engineering |
issn |
2040-2295 2040-2309 |
publishDate |
2019-01-01 |
description |
Background. Utilization of the widely used wearable sensor and smartphone technology for remote monitoring represents a healthcare breakthrough. This study aims to design a remote real-time monitoring system for multiple physiological parameters (electrocardiogram, heart rate, respiratory rate, blood oxygen saturation, and temperature) based on smartphones, considering high performance, autoalarm generation, warning transmission, and security through more than one method. Methods. Data on monitoring parameters were acquired by the integrated circuits of wearable sensors and collected by an Arduino Mega 250 R3. The collected data were transmitted via a Wi-Fi interface to a smartphone. A patient application was developed to analyze, process, and display the data in numerical and graphical forms. The abnormality threshold values of parameters were identified and analyzed to generate an autoalarm in the system and transmitted with data to a doctor application via a third-generation (3G) mobile network and Wi-Fi. The performance of the proposed system was verified and evaluated. The proposed system was designed to meet main (sensing, processing, displaying, real-time transmission, autoalarm generation, and threshold value identification) and auxiliary requirements (compatibility, comfort, low power consumption and cost, small size, and suitability for ambulatory applications). Results. System performance is reliable, with a sufficient average accuracy measurement (99.26%). The system demonstrates an average time delay of 14 s in transmitting data to a doctor application via Wi-Fi compared with an average time of 68 s via a 3G mobile network. The proposed system achieves low power consumption against time (4 h 21 m 30 s) and the main and auxiliary requirements for remotely monitoring multiple parameters simultaneously with secure data. Conclusions. The proposed system can offer economic benefits for remotely monitoring patients living alone or in rural areas, thereby improving medical services, if manufactured in large quantities. |
url |
http://dx.doi.org/10.1155/2019/5674673 |
work_keys_str_mv |
AT nomanqalnaggar designofaremoterealtimemonitoringsystemformultiplephysiologicalparametersbasedonsmartphone AT husammohammedalhammadi designofaremoterealtimemonitoringsystemformultiplephysiologicalparametersbasedonsmartphone AT adelmohammedalfusail designofaremoterealtimemonitoringsystemformultiplephysiologicalparametersbasedonsmartphone AT zakaryaalialshaebi designofaremoterealtimemonitoringsystemformultiplephysiologicalparametersbasedonsmartphone |
_version_ |
1725104618966351872 |