Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.

<h4>Background</h4>Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO2), and haemoglobin saturation (SaO2), are the indices used in clinica...

Full description

Bibliographic Details
Main Authors: Vatshalan Santhirapala, Louisa C Williams, Hannah C Tighe, James E Jackson, Claire L Shovlin
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2014-01-01
Series:PLoS ONE
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24637882/pdf/?tool=EBI
id doaj-808769cc988441b2bfe0ab93fd467bd3
record_format Article
spelling doaj-808769cc988441b2bfe0ab93fd467bd32021-03-04T09:41:39ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-0193e9077710.1371/journal.pone.0090777Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.Vatshalan SanthirapalaLouisa C WilliamsHannah C TigheJames E JacksonClaire L Shovlin<h4>Background</h4>Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO2), and haemoglobin saturation (SaO2), are the indices used in clinical assessments, and usually result from low inspired oxygen concentrations, or alveolar/airways disease. Our objective was to examine low blood oxygen/haemoglobin relationships in chronically compensated states without concurrent hypoxic pulmonary vasoreactivity.<h4>Methodology</h4>165 consecutive unselected patients with pulmonary arteriovenous malformations were studied, in 98 cases, pre/post embolisation treatment. 159 (96%) had hereditary haemorrhagic telangiectasia. Arterial oxygen content was calculated by SaO2 x haemoglobin x 1.34/100.<h4>Principal findings</h4>There was wide variation in SaO2 on air (78.5-99, median 95)% but due to secondary erythrocytosis and resultant polycythaemia, SaO2 explained only 0.1% of the variance in arterial oxygen content per unit blood volume. Secondary erythrocytosis was achievable with low iron stores, but only if serum iron was high-normal: Low serum iron levels were associated with reduced haemoglobin per erythrocyte, and overall arterial oxygen content was lower in iron deficient patients (median 16.0 [IQR 14.9, 17.4]mls/dL compared to 18.8 [IQR 17.4, 20.1]mls/dL, p<0.0001). Exercise tolerance appeared unrelated to SaO2 but was significantly worse in patients with lower oxygen content (p<0.0001). A pre-defined athletic group had higher Hb:SaO2 and serum iron:ferritin ratios than non-athletes with normal exercise capacity. PAVM embolisation increased SaO2, but arterial oxygen content was precisely restored by a subsequent fall in haemoglobin: 86 (87.8%) patients reported no change in exercise tolerance at post-embolisation follow-up.<h4>Significance</h4>Haemoglobin and oxygen measurements in isolation do not indicate the more physiologically relevant oxygen content per unit blood volume. This can be maintained for SaO2 ≥78.5%, and resets to the same arterial oxygen content after correction of hypoxaemia. Serum iron concentrations, not ferritin, seem to predict more successful polycythaemic responses.https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24637882/pdf/?tool=EBI
collection DOAJ
language English
format Article
sources DOAJ
author Vatshalan Santhirapala
Louisa C Williams
Hannah C Tighe
James E Jackson
Claire L Shovlin
spellingShingle Vatshalan Santhirapala
Louisa C Williams
Hannah C Tighe
James E Jackson
Claire L Shovlin
Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.
PLoS ONE
author_facet Vatshalan Santhirapala
Louisa C Williams
Hannah C Tighe
James E Jackson
Claire L Shovlin
author_sort Vatshalan Santhirapala
title Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.
title_short Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.
title_full Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.
title_fullStr Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.
title_full_unstemmed Arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.
title_sort arterial oxygen content is precisely maintained by graded erythrocytotic responses in settings of high/normal serum iron levels, and predicts exercise capacity: an observational study of hypoxaemic patients with pulmonary arteriovenous malformations.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2014-01-01
description <h4>Background</h4>Oxygen, haemoglobin and cardiac output are integrated components of oxygen transport: each gram of haemoglobin transports 1.34 mls of oxygen in the blood. Low arterial partial pressure of oxygen (PaO2), and haemoglobin saturation (SaO2), are the indices used in clinical assessments, and usually result from low inspired oxygen concentrations, or alveolar/airways disease. Our objective was to examine low blood oxygen/haemoglobin relationships in chronically compensated states without concurrent hypoxic pulmonary vasoreactivity.<h4>Methodology</h4>165 consecutive unselected patients with pulmonary arteriovenous malformations were studied, in 98 cases, pre/post embolisation treatment. 159 (96%) had hereditary haemorrhagic telangiectasia. Arterial oxygen content was calculated by SaO2 x haemoglobin x 1.34/100.<h4>Principal findings</h4>There was wide variation in SaO2 on air (78.5-99, median 95)% but due to secondary erythrocytosis and resultant polycythaemia, SaO2 explained only 0.1% of the variance in arterial oxygen content per unit blood volume. Secondary erythrocytosis was achievable with low iron stores, but only if serum iron was high-normal: Low serum iron levels were associated with reduced haemoglobin per erythrocyte, and overall arterial oxygen content was lower in iron deficient patients (median 16.0 [IQR 14.9, 17.4]mls/dL compared to 18.8 [IQR 17.4, 20.1]mls/dL, p<0.0001). Exercise tolerance appeared unrelated to SaO2 but was significantly worse in patients with lower oxygen content (p<0.0001). A pre-defined athletic group had higher Hb:SaO2 and serum iron:ferritin ratios than non-athletes with normal exercise capacity. PAVM embolisation increased SaO2, but arterial oxygen content was precisely restored by a subsequent fall in haemoglobin: 86 (87.8%) patients reported no change in exercise tolerance at post-embolisation follow-up.<h4>Significance</h4>Haemoglobin and oxygen measurements in isolation do not indicate the more physiologically relevant oxygen content per unit blood volume. This can be maintained for SaO2 ≥78.5%, and resets to the same arterial oxygen content after correction of hypoxaemia. Serum iron concentrations, not ferritin, seem to predict more successful polycythaemic responses.
url https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/24637882/pdf/?tool=EBI
work_keys_str_mv AT vatshalansanthirapala arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
AT louisacwilliams arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
AT hannahctighe arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
AT jamesejackson arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
AT clairelshovlin arterialoxygencontentispreciselymaintainedbygradederythrocytoticresponsesinsettingsofhighnormalserumironlevelsandpredictsexercisecapacityanobservationalstudyofhypoxaemicpatientswithpulmonaryarteriovenousmalformations
_version_ 1714806955884675072