EVALUATION OF LANDFILL LEACHATE POLLUTION: FINDINGS FROM A MONITORING STUDY AT MUNICIPAL WASTE LANDFILL
The monitoring that was carried out at the landfill specialized in leachate, groundwater and surface water. There were 6 sampling sites. The observed parameters were pH, BOD<sub>5</sub>, COD<sub>Cr</sub>, conductivity. Leachate reached the high values in all observed paramete...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Polish Society of Ecological Engineering (PTIE)
2015-02-01
|
Series: | Journal of Ecological Engineering |
Subjects: | |
Online Access: | http://www.jeeng.net/Evaluation-of-landfill-leachate-pollution-findings-from-a-monitoring-study-at-municipal-waste-landfill,1855,0,2.html |
id |
doaj-8048db07f11e4ef68005f1d7405f0223 |
---|---|
record_format |
Article |
spelling |
doaj-8048db07f11e4ef68005f1d7405f02232020-11-24T23:14:23ZengPolish Society of Ecological Engineering (PTIE)Journal of Ecological Engineering2299-89932015-02-01162193210.12911/22998993/18551855EVALUATION OF LANDFILL LEACHATE POLLUTION: FINDINGS FROM A MONITORING STUDY AT MUNICIPAL WASTE LANDFILLMagdalena Daria Vaverková0Dana Adamcová1Faculty of Agronomy, Mendel University in Brno, Zemědělská 1665/1, 613 00 Brno, Czech RepublicFaculty of Agronomy, Mendel University in Brno, Zemědělská 1665/1, 613 00 Brno, Czech RepublicThe monitoring that was carried out at the landfill specialized in leachate, groundwater and surface water. There were 6 sampling sites. The observed parameters were pH, BOD<sub>5</sub>, COD<sub>Cr</sub>, conductivity. Leachate reached the high values in all observed parameters. Groundwater samples were collected at two monitoring wells and the sampling site (A, B, C). Surface water was collected from two sampling sites (D, E). The pH showed slightly acid values at all sampling points. The pH of surface water was slightly acid to neutral. Both BOD<sub>5</sub> and COD<sub>Cr</sub> values remained stable over the reporting period. The average conductivity value at sampling points D, E remained constant. In line with the Czech National Standard ČSN 75 7221 “Classification of Surface Water Quality” sampling point D belongs to II Water Quality Class – slightly polluted water and sampling site E to Class I water quality – unpolluted water. The authors believe that the fluctuations occurring with regard to the values of certain samples were not caused by the operation of the landfill itself, but were a result of the intense agricultural activity nearby the landfill.http://www.jeeng.net/Evaluation-of-landfill-leachate-pollution-findings-from-a-monitoring-study-at-municipal-waste-landfill,1855,0,2.htmlgroundwater monitoringleachate monitoringmunicipal solid waste landfillsurface waterwater monitoring |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Magdalena Daria Vaverková Dana Adamcová |
spellingShingle |
Magdalena Daria Vaverková Dana Adamcová EVALUATION OF LANDFILL LEACHATE POLLUTION: FINDINGS FROM A MONITORING STUDY AT MUNICIPAL WASTE LANDFILL Journal of Ecological Engineering groundwater monitoring leachate monitoring municipal solid waste landfill surface water water monitoring |
author_facet |
Magdalena Daria Vaverková Dana Adamcová |
author_sort |
Magdalena Daria Vaverková |
title |
EVALUATION OF LANDFILL LEACHATE POLLUTION: FINDINGS FROM A MONITORING STUDY AT MUNICIPAL WASTE LANDFILL |
title_short |
EVALUATION OF LANDFILL LEACHATE POLLUTION: FINDINGS FROM A MONITORING STUDY AT MUNICIPAL WASTE LANDFILL |
title_full |
EVALUATION OF LANDFILL LEACHATE POLLUTION: FINDINGS FROM A MONITORING STUDY AT MUNICIPAL WASTE LANDFILL |
title_fullStr |
EVALUATION OF LANDFILL LEACHATE POLLUTION: FINDINGS FROM A MONITORING STUDY AT MUNICIPAL WASTE LANDFILL |
title_full_unstemmed |
EVALUATION OF LANDFILL LEACHATE POLLUTION: FINDINGS FROM A MONITORING STUDY AT MUNICIPAL WASTE LANDFILL |
title_sort |
evaluation of landfill leachate pollution: findings from a monitoring study at municipal waste landfill |
publisher |
Polish Society of Ecological Engineering (PTIE) |
series |
Journal of Ecological Engineering |
issn |
2299-8993 |
publishDate |
2015-02-01 |
description |
The monitoring that was carried out at the landfill specialized in leachate, groundwater and surface water. There were 6 sampling sites. The observed parameters were pH, BOD<sub>5</sub>, COD<sub>Cr</sub>, conductivity. Leachate reached the high values in all observed parameters. Groundwater samples were collected at two monitoring wells and the sampling site (A, B, C). Surface water was collected from two sampling sites (D, E). The pH showed slightly acid values at all sampling points. The pH of surface water was slightly acid to neutral. Both BOD<sub>5</sub> and COD<sub>Cr</sub> values remained stable over the reporting period. The average conductivity value at sampling points D, E remained constant. In line with the Czech National Standard ČSN 75 7221 “Classification of Surface Water Quality” sampling point D belongs to II Water Quality Class – slightly polluted water and sampling site E to Class I water quality – unpolluted water. The authors believe that the fluctuations occurring with regard to the values of certain samples were not caused by the operation of the landfill itself, but were a result of the intense agricultural activity nearby the landfill. |
topic |
groundwater monitoring leachate monitoring municipal solid waste landfill surface water water monitoring |
url |
http://www.jeeng.net/Evaluation-of-landfill-leachate-pollution-findings-from-a-monitoring-study-at-municipal-waste-landfill,1855,0,2.html |
work_keys_str_mv |
AT magdalenadariavaverkova evaluationoflandfillleachatepollutionfindingsfromamonitoringstudyatmunicipalwastelandfill AT danaadamcova evaluationoflandfillleachatepollutionfindingsfromamonitoringstudyatmunicipalwastelandfill |
_version_ |
1725594656663666688 |