Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach
Objective: To determine the time to radiological union and final functional outcome of fixation of extra-articular distal humeral fractures with extra-artricular distal humerus locking plate.Methods: This prospective study was conducted from March 2014 to February 2018 and included extra-articular d...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Shiraz University of Medical Sciences
2018-10-01
|
Series: | Bulletin of Emergency and Trauma |
Subjects: | |
Online Access: | http://beat.sums.ac.ir/article_44453_2c00ca1d1d1d0aab5e24c583b2347245.pdf |
id |
doaj-8041bdb453c44713b66f15ed318df360 |
---|---|
record_format |
Article |
spelling |
doaj-8041bdb453c44713b66f15ed318df3602020-11-24T23:56:52ZengShiraz University of Medical SciencesBulletin of Emergency and Trauma2322-25222322-39602018-10-016Issue 430631210.29252/beat-06040644453Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral ApproachNadeem Ali0Naseer Mir1Tahir Dar2Mohmad Rather3Wajahat Mir4Senin Shah5Saheel Maajid6Hospital for Bone and Joint Surgery, Barzulla, GMC Srinagar.SKIMS Medical College and Hospital, BeminaSKIMS Medical College and Hospital, BeminaSKIMS Medical College and Hospital, BeminaSKIMS Medical College and Hospital, BeminaKasturba Medical CollegeSKIMS Medical College and Hospital, BeminaObjective: To determine the time to radiological union and final functional outcome of fixation of extra-articular distal humeral fractures with extra-artricular distal humerus locking plate.Methods: This prospective study was conducted from March 2014 to February 2018 and included extra-articular distal humeral fractures managed by operative fixation using extra-articular distal humerus locking plate. All the fractures were approached using lateral para-tricepetal approach of Gervin, and stabilized with extra-articular distal humerus locking plate with or without lag screws. Time to radiological union was assessed in the follow up and at the final follow up functional outcome was evaluated using Mayo Performance Elbow Score (MEPS). Complications and need for any additional procedures was also recorded.Results: A total of 20 patients with mean age of 36.5 years and an average follow up of 17 months were included. The mean time to radiological union was 17.4 weeks (12 to 36 weeks) which included one delayed union that required bone grafting. The mean flexion at elbow was 127o with only one patient having flexion extension arc movement of less than 100o at the final follow up. The average MEPS at final follow up was 94.7±8 with 19 patients having excellent and good results.Conclusion: Use of extra-articular distal humeral locking plate using lateral para-tricepetal approach in extra-articular distal humeral fractures allows stable fixation of the fracture to allow early return to function with minimal soft tissue dissection and excellent final functional results and minimum complications.http://beat.sums.ac.ir/article_44453_2c00ca1d1d1d0aab5e24c583b2347245.pdfHumerusFractureElbowLocking plateExtra-articular |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Nadeem Ali Naseer Mir Tahir Dar Mohmad Rather Wajahat Mir Senin Shah Saheel Maajid |
spellingShingle |
Nadeem Ali Naseer Mir Tahir Dar Mohmad Rather Wajahat Mir Senin Shah Saheel Maajid Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach Bulletin of Emergency and Trauma Humerus Fracture Elbow Locking plate Extra-articular |
author_facet |
Nadeem Ali Naseer Mir Tahir Dar Mohmad Rather Wajahat Mir Senin Shah Saheel Maajid |
author_sort |
Nadeem Ali |
title |
Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach |
title_short |
Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach |
title_full |
Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach |
title_fullStr |
Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach |
title_full_unstemmed |
Outcome of Extra-Articular Distal Humerus Fractures Fixed by Single Column Extra-Articular Distal Humerus Locking Compression Plate Using Triceps Sparing Postero-Lateral Approach |
title_sort |
outcome of extra-articular distal humerus fractures fixed by single column extra-articular distal humerus locking compression plate using triceps sparing postero-lateral approach |
publisher |
Shiraz University of Medical Sciences |
series |
Bulletin of Emergency and Trauma |
issn |
2322-2522 2322-3960 |
publishDate |
2018-10-01 |
description |
Objective: To determine the time to radiological union and final functional outcome of fixation of extra-articular distal humeral fractures with extra-artricular distal humerus locking plate.Methods: This prospective study was conducted from March 2014 to February 2018 and included extra-articular distal humeral fractures managed by operative fixation using extra-articular distal humerus locking plate. All the fractures were approached using lateral para-tricepetal approach of Gervin, and stabilized with extra-articular distal humerus locking plate with or without lag screws. Time to radiological union was assessed in the follow up and at the final follow up functional outcome was evaluated using Mayo Performance Elbow Score (MEPS). Complications and need for any additional procedures was also recorded.Results: A total of 20 patients with mean age of 36.5 years and an average follow up of 17 months were included. The mean time to radiological union was 17.4 weeks (12 to 36 weeks) which included one delayed union that required bone grafting. The mean flexion at elbow was 127o with only one patient having flexion extension arc movement of less than 100o at the final follow up. The average MEPS at final follow up was 94.7±8 with 19 patients having excellent and good results.Conclusion: Use of extra-articular distal humeral locking plate using lateral para-tricepetal approach in extra-articular distal humeral fractures allows stable fixation of the fracture to allow early return to function with minimal soft tissue dissection and excellent final functional results and minimum complications. |
topic |
Humerus Fracture Elbow Locking plate Extra-articular |
url |
http://beat.sums.ac.ir/article_44453_2c00ca1d1d1d0aab5e24c583b2347245.pdf |
work_keys_str_mv |
AT nadeemali outcomeofextraarticulardistalhumerusfracturesfixedbysinglecolumnextraarticulardistalhumeruslockingcompressionplateusingtricepssparingposterolateralapproach AT naseermir outcomeofextraarticulardistalhumerusfracturesfixedbysinglecolumnextraarticulardistalhumeruslockingcompressionplateusingtricepssparingposterolateralapproach AT tahirdar outcomeofextraarticulardistalhumerusfracturesfixedbysinglecolumnextraarticulardistalhumeruslockingcompressionplateusingtricepssparingposterolateralapproach AT mohmadrather outcomeofextraarticulardistalhumerusfracturesfixedbysinglecolumnextraarticulardistalhumeruslockingcompressionplateusingtricepssparingposterolateralapproach AT wajahatmir outcomeofextraarticulardistalhumerusfracturesfixedbysinglecolumnextraarticulardistalhumeruslockingcompressionplateusingtricepssparingposterolateralapproach AT seninshah outcomeofextraarticulardistalhumerusfracturesfixedbysinglecolumnextraarticulardistalhumeruslockingcompressionplateusingtricepssparingposterolateralapproach AT saheelmaajid outcomeofextraarticulardistalhumerusfracturesfixedbysinglecolumnextraarticulardistalhumeruslockingcompressionplateusingtricepssparingposterolateralapproach |
_version_ |
1725456095501090816 |