Study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboard

The domestic logistics industry has developed rapidly, and then a large number of logistics warehouses adopting mezzanine shelving system have emerged. Aiming at the influence of the hollowed floorboard structure of the mezzanine shelving system on the fire hazard of the logistics warehouse, the pap...

Full description

Bibliographic Details
Main Authors: Yaxin Tan, Jing Li, Yufeng Li, Yufeng Huang
Format: Article
Language:English
Published: Elsevier 2019-09-01
Series:Case Studies in Thermal Engineering
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X19300474
id doaj-80296c4c55634c21985f62b9c1d813d3
record_format Article
spelling doaj-80296c4c55634c21985f62b9c1d813d32020-11-25T01:54:35ZengElsevierCase Studies in Thermal Engineering2214-157X2019-09-0114Study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboardYaxin Tan0Jing Li1Yufeng Li2Yufeng Huang3College of Electronic and Information Engineering, Shenyang Aerospace University, Shenyang, Liaoning, 110136, PR ChinaCollege of Electronic and Information Engineering, Shenyang Aerospace University, Shenyang, Liaoning, 110136, PR ChinaCollege of Electronic and Information Engineering, Shenyang Aerospace University, Shenyang, Liaoning, 110136, PR ChinaCorresponding author.; College of Electronic and Information Engineering, Shenyang Aerospace University, Shenyang, Liaoning, 110136, PR ChinaThe domestic logistics industry has developed rapidly, and then a large number of logistics warehouses adopting mezzanine shelving system have emerged. Aiming at the influence of the hollowed floorboard structure of the mezzanine shelving system on the fire hazard of the logistics warehouse, the paper analyzes the smoke temperature under the impact of the hollowing rate of the mezzanine shelving system through the fire smoke spread process, and evaluates the hollowing rate of 5%, 10%, 15%, 20%, 25%, 30%, and 50%. Through FDS (Fire Dynamics Simulator) simulation study, the results verify that along with the decrease of the hollowing rate and the increase of the distance, the smoke temperature gradually reduces; Furthermore, the functional relationship between respond temperature of the automatic sprinkler system and the hollowing rate was fitted by the functional relationshipY=a(1−e−bx). The R value of the position which directly above the fire source was about 0.99, and the fitting result was desirable. The research results have certain practical value for the design of automatic sprinkler system and fire risk analysis of logistics warehouses with mezzanine shelving system. Keywords: Logistics warehouse fire, Hollow floorboard, Automatic sprinkler system, Temperaturehttp://www.sciencedirect.com/science/article/pii/S2214157X19300474
collection DOAJ
language English
format Article
sources DOAJ
author Yaxin Tan
Jing Li
Yufeng Li
Yufeng Huang
spellingShingle Yaxin Tan
Jing Li
Yufeng Li
Yufeng Huang
Study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboard
Case Studies in Thermal Engineering
author_facet Yaxin Tan
Jing Li
Yufeng Li
Yufeng Huang
author_sort Yaxin Tan
title Study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboard
title_short Study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboard
title_full Study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboard
title_fullStr Study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboard
title_full_unstemmed Study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboard
title_sort study on the response of sprinkler system in logistics warehouse under the influence of the hollow floorboard
publisher Elsevier
series Case Studies in Thermal Engineering
issn 2214-157X
publishDate 2019-09-01
description The domestic logistics industry has developed rapidly, and then a large number of logistics warehouses adopting mezzanine shelving system have emerged. Aiming at the influence of the hollowed floorboard structure of the mezzanine shelving system on the fire hazard of the logistics warehouse, the paper analyzes the smoke temperature under the impact of the hollowing rate of the mezzanine shelving system through the fire smoke spread process, and evaluates the hollowing rate of 5%, 10%, 15%, 20%, 25%, 30%, and 50%. Through FDS (Fire Dynamics Simulator) simulation study, the results verify that along with the decrease of the hollowing rate and the increase of the distance, the smoke temperature gradually reduces; Furthermore, the functional relationship between respond temperature of the automatic sprinkler system and the hollowing rate was fitted by the functional relationshipY=a(1−e−bx). The R value of the position which directly above the fire source was about 0.99, and the fitting result was desirable. The research results have certain practical value for the design of automatic sprinkler system and fire risk analysis of logistics warehouses with mezzanine shelving system. Keywords: Logistics warehouse fire, Hollow floorboard, Automatic sprinkler system, Temperature
url http://www.sciencedirect.com/science/article/pii/S2214157X19300474
work_keys_str_mv AT yaxintan studyontheresponseofsprinklersysteminlogisticswarehouseundertheinfluenceofthehollowfloorboard
AT jingli studyontheresponseofsprinklersysteminlogisticswarehouseundertheinfluenceofthehollowfloorboard
AT yufengli studyontheresponseofsprinklersysteminlogisticswarehouseundertheinfluenceofthehollowfloorboard
AT yufenghuang studyontheresponseofsprinklersysteminlogisticswarehouseundertheinfluenceofthehollowfloorboard
_version_ 1724986499139633152