Sequence polymorphism can produce serious artefacts in real-time PCR assays: hard lessons from Pacific oysters

<p>Abstract</p> <p>Background</p> <p>Since it was first described in the mid-1990s, quantitative real time PCR (Q-PCR) has been widely used in many fields of biomedical research and molecular diagnostics. This method is routinely used to validate whole transcriptome ana...

Full description

Bibliographic Details
Main Authors: Camara Mark D, Lang Robert P, Taris Nicolas
Format: Article
Language:English
Published: BMC 2008-05-01
Series:BMC Genomics
Online Access:http://www.biomedcentral.com/1471-2164/9/234
id doaj-7fd337d1d8bd49daaf5e50eee00a1ff9
record_format Article
spelling doaj-7fd337d1d8bd49daaf5e50eee00a1ff92020-11-25T01:27:25ZengBMCBMC Genomics1471-21642008-05-019123410.1186/1471-2164-9-234Sequence polymorphism can produce serious artefacts in real-time PCR assays: hard lessons from Pacific oystersCamara Mark DLang Robert PTaris Nicolas<p>Abstract</p> <p>Background</p> <p>Since it was first described in the mid-1990s, quantitative real time PCR (Q-PCR) has been widely used in many fields of biomedical research and molecular diagnostics. This method is routinely used to validate whole transcriptome analyses such as DNA microarrays, suppressive subtractive hybridization (SSH) or differential display techniques such as cDNA-AFLP (Amplification Fragment Length Polymorphism). Despite efforts to optimize the methodology, misleading results are still possible, even when standard optimization approaches are followed.</p> <p>Results</p> <p>As part of a larger project aimed at elucidating transcriptome-level responses of Pacific oysters (<it>Crassostrea gigas</it>) to various environmental stressors, we used microarrays and cDNA-AFLP to identify Expressed Sequence Tag (EST) fragments that are differentially expressed in response to bacterial challenge in two heat shock tolerant and two heat shock sensitive full-sib oyster families. We then designed primers for these differentially expressed ESTs in order to validate the results using Q-PCR. For two of these ESTs we tested fourteen primer pairs each and using standard optimization methods (i.e. melt-curve analysis to ensure amplification of a single product), determined that of the fourteen primer pairs tested, six and nine pairs respectively amplified a single product and were thus acceptable for further testing. However, when we used these primers, we obtained different statistical outcomes among primer pairs, raising unexpected but serious questions about their reliability. We hypothesize that as a consequence of high levels of sequence polymorphism in Pacific oysters, Q-PCR amplification is sub-optimal in some individuals because sequence variants in priming sites results in poor primer binding and amplification in some individuals. This issue is similar to the high frequency of null alleles observed for microsatellite markers in Pacific oysters.</p> <p>Conclusion</p> <p>This study highlights potential difficulties for using Q-PCR as a validation tool for transcriptome analysis in the presence of sequence polymorphism and emphasizes the need for extreme caution and thorough primer testing when assaying genetically diverse biological materials such as Pacific oysters. Our findings suggest that melt-curve analysis alone may not be sufficient as a mean of identifying acceptable Q-PCR primers. Minimally, testing numerous primer pairs seems to be necessary to avoid false conclusions from flawed Q-PCR assays for which sequence variation among individuals produces artifactual and unreliable quantitative results.</p> http://www.biomedcentral.com/1471-2164/9/234
collection DOAJ
language English
format Article
sources DOAJ
author Camara Mark D
Lang Robert P
Taris Nicolas
spellingShingle Camara Mark D
Lang Robert P
Taris Nicolas
Sequence polymorphism can produce serious artefacts in real-time PCR assays: hard lessons from Pacific oysters
BMC Genomics
author_facet Camara Mark D
Lang Robert P
Taris Nicolas
author_sort Camara Mark D
title Sequence polymorphism can produce serious artefacts in real-time PCR assays: hard lessons from Pacific oysters
title_short Sequence polymorphism can produce serious artefacts in real-time PCR assays: hard lessons from Pacific oysters
title_full Sequence polymorphism can produce serious artefacts in real-time PCR assays: hard lessons from Pacific oysters
title_fullStr Sequence polymorphism can produce serious artefacts in real-time PCR assays: hard lessons from Pacific oysters
title_full_unstemmed Sequence polymorphism can produce serious artefacts in real-time PCR assays: hard lessons from Pacific oysters
title_sort sequence polymorphism can produce serious artefacts in real-time pcr assays: hard lessons from pacific oysters
publisher BMC
series BMC Genomics
issn 1471-2164
publishDate 2008-05-01
description <p>Abstract</p> <p>Background</p> <p>Since it was first described in the mid-1990s, quantitative real time PCR (Q-PCR) has been widely used in many fields of biomedical research and molecular diagnostics. This method is routinely used to validate whole transcriptome analyses such as DNA microarrays, suppressive subtractive hybridization (SSH) or differential display techniques such as cDNA-AFLP (Amplification Fragment Length Polymorphism). Despite efforts to optimize the methodology, misleading results are still possible, even when standard optimization approaches are followed.</p> <p>Results</p> <p>As part of a larger project aimed at elucidating transcriptome-level responses of Pacific oysters (<it>Crassostrea gigas</it>) to various environmental stressors, we used microarrays and cDNA-AFLP to identify Expressed Sequence Tag (EST) fragments that are differentially expressed in response to bacterial challenge in two heat shock tolerant and two heat shock sensitive full-sib oyster families. We then designed primers for these differentially expressed ESTs in order to validate the results using Q-PCR. For two of these ESTs we tested fourteen primer pairs each and using standard optimization methods (i.e. melt-curve analysis to ensure amplification of a single product), determined that of the fourteen primer pairs tested, six and nine pairs respectively amplified a single product and were thus acceptable for further testing. However, when we used these primers, we obtained different statistical outcomes among primer pairs, raising unexpected but serious questions about their reliability. We hypothesize that as a consequence of high levels of sequence polymorphism in Pacific oysters, Q-PCR amplification is sub-optimal in some individuals because sequence variants in priming sites results in poor primer binding and amplification in some individuals. This issue is similar to the high frequency of null alleles observed for microsatellite markers in Pacific oysters.</p> <p>Conclusion</p> <p>This study highlights potential difficulties for using Q-PCR as a validation tool for transcriptome analysis in the presence of sequence polymorphism and emphasizes the need for extreme caution and thorough primer testing when assaying genetically diverse biological materials such as Pacific oysters. Our findings suggest that melt-curve analysis alone may not be sufficient as a mean of identifying acceptable Q-PCR primers. Minimally, testing numerous primer pairs seems to be necessary to avoid false conclusions from flawed Q-PCR assays for which sequence variation among individuals produces artifactual and unreliable quantitative results.</p>
url http://www.biomedcentral.com/1471-2164/9/234
work_keys_str_mv AT camaramarkd sequencepolymorphismcanproduceseriousartefactsinrealtimepcrassayshardlessonsfrompacificoysters
AT langrobertp sequencepolymorphismcanproduceseriousartefactsinrealtimepcrassayshardlessonsfrompacificoysters
AT tarisnicolas sequencepolymorphismcanproduceseriousartefactsinrealtimepcrassayshardlessonsfrompacificoysters
_version_ 1725105748508147712