Modeling and Simulation of Out of Step Blocking Relay for
<p> This paper investigates a power swing effect on a distance protection relay performance installed on (HV/EHV) transmission line as well as power system stability. A conventional distance relay can’t properly operate under transient stability conditions; therefore, it cause mol-operation, a...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Tikrit University
2013-05-01
|
Series: | Tikrit Journal of Engineering Sciences |
Subjects: | |
Online Access: | http://www.tj-es.com/ojs/index.php/tjes/article/view/166 |
id |
doaj-7f3c52f38458479d867a0c9eaa6addd4 |
---|---|
record_format |
Article |
spelling |
doaj-7f3c52f38458479d867a0c9eaa6addd42020-11-24T21:50:09ZengTikrit UniversityTikrit Journal of Engineering Sciences1813-162X2312-75892013-05-011712131112Modeling and Simulation of Out of Step Blocking Relay forAhmed A. Al Adwani<p> This paper investigates a power swing effect on a distance protection relay performance installed on (HV/EHV) transmission line as well as power system stability. A conventional distance relay can’t properly operate under transient stability conditions; therefore, it cause mol-operation, and it will adversely impact on its trip signals. To overcome this problem, the Out Of Step (OOS) relay has modeled and simulated to joint with distance relay to supervise and control on its trip signals response. The setting characteristics technique of the OOS based on concentric polygons scheme method to detect power swing under transient stability situation.</p><p> This study ia a modeling and simulating using (<strong>Maltab\ Simulink</strong>) software. A Two relays had been performed and tested with two equivalents network connected to ends.</p><p> The results of this study showed an activity and reliability of this way to control the distance relay response under a transient stability conditions and it indicated the possibility to find out faults which may occur at period of power swing</p>http://www.tj-es.com/ojs/index.php/tjes/article/view/166Power swing, Distance relay Out of step protection technique |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ahmed A. Al Adwani |
spellingShingle |
Ahmed A. Al Adwani Modeling and Simulation of Out of Step Blocking Relay for Tikrit Journal of Engineering Sciences Power swing, Distance relay Out of step protection technique |
author_facet |
Ahmed A. Al Adwani |
author_sort |
Ahmed A. Al Adwani |
title |
Modeling and Simulation of Out of Step Blocking Relay for |
title_short |
Modeling and Simulation of Out of Step Blocking Relay for |
title_full |
Modeling and Simulation of Out of Step Blocking Relay for |
title_fullStr |
Modeling and Simulation of Out of Step Blocking Relay for |
title_full_unstemmed |
Modeling and Simulation of Out of Step Blocking Relay for |
title_sort |
modeling and simulation of out of step blocking relay for |
publisher |
Tikrit University |
series |
Tikrit Journal of Engineering Sciences |
issn |
1813-162X 2312-7589 |
publishDate |
2013-05-01 |
description |
<p> This paper investigates a power swing effect on a distance protection relay performance installed on (HV/EHV) transmission line as well as power system stability. A conventional distance relay can’t properly operate under transient stability conditions; therefore, it cause mol-operation, and it will adversely impact on its trip signals. To overcome this problem, the Out Of Step (OOS) relay has modeled and simulated to joint with distance relay to supervise and control on its trip signals response. The setting characteristics technique of the OOS based on concentric polygons scheme method to detect power swing under transient stability situation.</p><p> This study ia a modeling and simulating using (<strong>Maltab\ Simulink</strong>) software. A Two relays had been performed and tested with two equivalents network connected to ends.</p><p> The results of this study showed an activity and reliability of this way to control the distance relay response under a transient stability conditions and it indicated the possibility to find out faults which may occur at period of power swing</p> |
topic |
Power swing, Distance relay Out of step protection technique |
url |
http://www.tj-es.com/ojs/index.php/tjes/article/view/166 |
work_keys_str_mv |
AT ahmedaaladwani modelingandsimulationofoutofstepblockingrelayfor |
_version_ |
1725884965677170688 |