Evaluation of Cyclic Corrosion on ASTM A335 P92 Steel Exposed to a Combustion Atmosphere in a Horizontal Boiler

The use of industrial boilers for steam generation at industrial level is carried out under high temperature conditions, generating potentials corrosive atmospheres composed by CO2, N2, O2 and H2O; causing the deterioration and wastage of steels mechanical properties in equipment, as well as large e...

Full description

Bibliographic Details
Main Authors: Juan Orozco, Anibal Alviz Meza, Viatcheslav Kafarov, Yesid Pena Ballesteros Dario, Camilo Osses, Maria Pinto
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2018-09-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/8889
id doaj-7efef109cab2474ebd6c913beeb18e6d
record_format Article
spelling doaj-7efef109cab2474ebd6c913beeb18e6d2021-02-17T20:57:08ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162018-09-016710.3303/CET1867003Evaluation of Cyclic Corrosion on ASTM A335 P92 Steel Exposed to a Combustion Atmosphere in a Horizontal BoilerJuan OrozcoAnibal Alviz MezaViatcheslav KafarovYesid Pena Ballesteros DarioCamilo OssesMaria PintoThe use of industrial boilers for steam generation at industrial level is carried out under high temperature conditions, generating potentials corrosive atmospheres composed by CO2, N2, O2 and H2O; causing the deterioration and wastage of steels mechanical properties in equipment, as well as large economic losses. In this research work, the high temperature corrosive behavior of ASTM A335 P92 steel exposed to a real combustion environment in a horizontal pirotubular boiler was evaluated. Through characterization techniques such as: X-Ray Diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM) and X-ray Dispersive Energy (EDX), the morphology of the oxide layer formed, and its corrosion products were obtained. For its part, the gravimetric technique was used to analyze the kinetic corrosion behavior of the alloy, due to the mass gain per unit area against the testing times 24, 48, 120, 240 and 360 h. These results lead to determinate the corrosion rate and the kinetic constant according to the oxide parabolic growth law. Finally, it is concluded that ASTM A335 P92 steel is an alloy of potential use in combustion environments, where it has shown an outstanding behaviour respect to cyclical thermal processes at high temperatures. However, the limitation of this study is represented in the short testing times.https://www.cetjournal.it/index.php/cet/article/view/8889
collection DOAJ
language English
format Article
sources DOAJ
author Juan Orozco
Anibal Alviz Meza
Viatcheslav Kafarov
Yesid Pena Ballesteros Dario
Camilo Osses
Maria Pinto
spellingShingle Juan Orozco
Anibal Alviz Meza
Viatcheslav Kafarov
Yesid Pena Ballesteros Dario
Camilo Osses
Maria Pinto
Evaluation of Cyclic Corrosion on ASTM A335 P92 Steel Exposed to a Combustion Atmosphere in a Horizontal Boiler
Chemical Engineering Transactions
author_facet Juan Orozco
Anibal Alviz Meza
Viatcheslav Kafarov
Yesid Pena Ballesteros Dario
Camilo Osses
Maria Pinto
author_sort Juan Orozco
title Evaluation of Cyclic Corrosion on ASTM A335 P92 Steel Exposed to a Combustion Atmosphere in a Horizontal Boiler
title_short Evaluation of Cyclic Corrosion on ASTM A335 P92 Steel Exposed to a Combustion Atmosphere in a Horizontal Boiler
title_full Evaluation of Cyclic Corrosion on ASTM A335 P92 Steel Exposed to a Combustion Atmosphere in a Horizontal Boiler
title_fullStr Evaluation of Cyclic Corrosion on ASTM A335 P92 Steel Exposed to a Combustion Atmosphere in a Horizontal Boiler
title_full_unstemmed Evaluation of Cyclic Corrosion on ASTM A335 P92 Steel Exposed to a Combustion Atmosphere in a Horizontal Boiler
title_sort evaluation of cyclic corrosion on astm a335 p92 steel exposed to a combustion atmosphere in a horizontal boiler
publisher AIDIC Servizi S.r.l.
series Chemical Engineering Transactions
issn 2283-9216
publishDate 2018-09-01
description The use of industrial boilers for steam generation at industrial level is carried out under high temperature conditions, generating potentials corrosive atmospheres composed by CO2, N2, O2 and H2O; causing the deterioration and wastage of steels mechanical properties in equipment, as well as large economic losses. In this research work, the high temperature corrosive behavior of ASTM A335 P92 steel exposed to a real combustion environment in a horizontal pirotubular boiler was evaluated. Through characterization techniques such as: X-Ray Diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM) and X-ray Dispersive Energy (EDX), the morphology of the oxide layer formed, and its corrosion products were obtained. For its part, the gravimetric technique was used to analyze the kinetic corrosion behavior of the alloy, due to the mass gain per unit area against the testing times 24, 48, 120, 240 and 360 h. These results lead to determinate the corrosion rate and the kinetic constant according to the oxide parabolic growth law. Finally, it is concluded that ASTM A335 P92 steel is an alloy of potential use in combustion environments, where it has shown an outstanding behaviour respect to cyclical thermal processes at high temperatures. However, the limitation of this study is represented in the short testing times.
url https://www.cetjournal.it/index.php/cet/article/view/8889
work_keys_str_mv AT juanorozco evaluationofcycliccorrosiononastma335p92steelexposedtoacombustionatmosphereinahorizontalboiler
AT anibalalvizmeza evaluationofcycliccorrosiononastma335p92steelexposedtoacombustionatmosphereinahorizontalboiler
AT viatcheslavkafarov evaluationofcycliccorrosiononastma335p92steelexposedtoacombustionatmosphereinahorizontalboiler
AT yesidpenaballesterosdario evaluationofcycliccorrosiononastma335p92steelexposedtoacombustionatmosphereinahorizontalboiler
AT camiloosses evaluationofcycliccorrosiononastma335p92steelexposedtoacombustionatmosphereinahorizontalboiler
AT mariapinto evaluationofcycliccorrosiononastma335p92steelexposedtoacombustionatmosphereinahorizontalboiler
_version_ 1724264787485917184