A Study on Performance of Low-Dose Medical Radiation Shielding Fiber (RSF) in CT Scans

In modern medicine, a radiation scans is an very important examination tool for making a diagnosis and subsequent treatment plan. Among the range of medical examinations, Computed tomography (CT) is being performed in an increasing number of cases and a CT scan uses the most radiation of any diagnos...

Full description

Bibliographic Details
Main Authors: Seon-Chil Kim, Hong-Moon Jung
Format: Article
Language:English
Published: Universitas Indonesia 2014-01-01
Series:International Journal of Technology
Subjects:
Online Access:http://ijtech.eng.ui.ac.id/article/view/1231
id doaj-7ee6042f85dc4f61a1fefc76fef299f0
record_format Article
spelling doaj-7ee6042f85dc4f61a1fefc76fef299f02020-11-25T01:38:33ZengUniversitas IndonesiaInternational Journal of Technology2086-96142087-21002014-01-014217818710.14716/ijtech.v4i2.12311231A Study on Performance of Low-Dose Medical Radiation Shielding Fiber (RSF) in CT ScansSeon-Chil Kim0Hong-Moon Jung1Department of Radiologic Technology, Daegu Health College, Daegu 702-722, KoreaDepartment of Radiologic Technology, Daegu Health College, Daegu 702-722, KoreaIn modern medicine, a radiation scans is an very important examination tool for making a diagnosis and subsequent treatment plan. Among the range of medical examinations, Computed tomography (CT) is being performed in an increasing number of cases and a CT scan uses the most radiation of any diagnostic exam. On the other hand, radiation protection during scanning is not typical for bodily regions other than those designated for examination. Therefore, the aim of this study was to develop a lead-free fused radiation shielding fiber (RSF) and to evaluate its effectiveness with a view to reducing radiation exposure to only the effective dose or less in a CT scan by means of a multilayer structural coating. A GE High Speed Advantage Spiral CT was used to conduct measurements using a FH-40G (Eberline, USA) proportional digital counter survey meter. In a brain CT scan, abdominal CT scan, and knee CT scan, two-way ANOVA was used to analyze the changes in radiation dosage and to examine the correlation based on body parts and thickness of the RSF. In addition, when significant results were obtained, a Duncan post hoc test was used to examine the difference depending on each condition. In the brain CT scan, the highest exposure to secondary radiation was measured in the chest, which was closest in distance. The use of a 3- mm shielding fiber resulted in a shielding effect of approximately 65% shielding effect compared to the initial exposure dose. In the abdominal CT scan, no exposure dose was detected in the head area, which had been shielded with the 3-mm shielding fiber. In a knee CT scan, 1-mm shielding fiber was sufficient to demonstrate a shielding effect. The RSF developed in this study may help reduce low-dose exposure to secondary X-rays, such as scattered rays.http://ijtech.eng.ui.ac.id/article/view/1231Barium, Computed tomography, Lead-free, Radiation shielding fiber
collection DOAJ
language English
format Article
sources DOAJ
author Seon-Chil Kim
Hong-Moon Jung
spellingShingle Seon-Chil Kim
Hong-Moon Jung
A Study on Performance of Low-Dose Medical Radiation Shielding Fiber (RSF) in CT Scans
International Journal of Technology
Barium, Computed tomography, Lead-free
, Radiation shielding fiber
author_facet Seon-Chil Kim
Hong-Moon Jung
author_sort Seon-Chil Kim
title A Study on Performance of Low-Dose Medical Radiation Shielding Fiber (RSF) in CT Scans
title_short A Study on Performance of Low-Dose Medical Radiation Shielding Fiber (RSF) in CT Scans
title_full A Study on Performance of Low-Dose Medical Radiation Shielding Fiber (RSF) in CT Scans
title_fullStr A Study on Performance of Low-Dose Medical Radiation Shielding Fiber (RSF) in CT Scans
title_full_unstemmed A Study on Performance of Low-Dose Medical Radiation Shielding Fiber (RSF) in CT Scans
title_sort study on performance of low-dose medical radiation shielding fiber (rsf) in ct scans
publisher Universitas Indonesia
series International Journal of Technology
issn 2086-9614
2087-2100
publishDate 2014-01-01
description In modern medicine, a radiation scans is an very important examination tool for making a diagnosis and subsequent treatment plan. Among the range of medical examinations, Computed tomography (CT) is being performed in an increasing number of cases and a CT scan uses the most radiation of any diagnostic exam. On the other hand, radiation protection during scanning is not typical for bodily regions other than those designated for examination. Therefore, the aim of this study was to develop a lead-free fused radiation shielding fiber (RSF) and to evaluate its effectiveness with a view to reducing radiation exposure to only the effective dose or less in a CT scan by means of a multilayer structural coating. A GE High Speed Advantage Spiral CT was used to conduct measurements using a FH-40G (Eberline, USA) proportional digital counter survey meter. In a brain CT scan, abdominal CT scan, and knee CT scan, two-way ANOVA was used to analyze the changes in radiation dosage and to examine the correlation based on body parts and thickness of the RSF. In addition, when significant results were obtained, a Duncan post hoc test was used to examine the difference depending on each condition. In the brain CT scan, the highest exposure to secondary radiation was measured in the chest, which was closest in distance. The use of a 3- mm shielding fiber resulted in a shielding effect of approximately 65% shielding effect compared to the initial exposure dose. In the abdominal CT scan, no exposure dose was detected in the head area, which had been shielded with the 3-mm shielding fiber. In a knee CT scan, 1-mm shielding fiber was sufficient to demonstrate a shielding effect. The RSF developed in this study may help reduce low-dose exposure to secondary X-rays, such as scattered rays.
topic Barium, Computed tomography, Lead-free
, Radiation shielding fiber
url http://ijtech.eng.ui.ac.id/article/view/1231
work_keys_str_mv AT seonchilkim astudyonperformanceoflowdosemedicalradiationshieldingfiberrsfinctscans
AT hongmoonjung astudyonperformanceoflowdosemedicalradiationshieldingfiberrsfinctscans
AT seonchilkim studyonperformanceoflowdosemedicalradiationshieldingfiberrsfinctscans
AT hongmoonjung studyonperformanceoflowdosemedicalradiationshieldingfiberrsfinctscans
_version_ 1725053107996459008