Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation
AIM. To estimate the capabilities of 99mTc-pyrphotech single-photon emission computed tomography (SPECT) in the diagnosis of myocardial inflammatory changes in patients with persistent atrial fibrillation (AF). MATERIALS AND METHODS. Nineteen patients (11 males and 8 females, mean age 47.46±9.92 yea...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
"Consilium Medicum" Publishing house
2014-12-01
|
Series: | Терапевтический архив |
Subjects: | |
Online Access: | https://ter-arkhiv.ru/0040-3660/article/view/31577 |
id |
doaj-7dd4742b89dd43e3bae1c8b6ae8793b8 |
---|---|
record_format |
Article |
spelling |
doaj-7dd4742b89dd43e3bae1c8b6ae8793b82020-11-25T03:32:54Zrus"Consilium Medicum" Publishing houseТерапевтический архив0040-36602309-53422014-12-018612101428593Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillationS I SazonovaIu B LishmanovR E BatalovS V PopovIu N Il'iushenkovaIu V RogovskaiaM Z IdrisovAIM. To estimate the capabilities of 99mTc-pyrphotech single-photon emission computed tomography (SPECT) in the diagnosis of myocardial inflammatory changes in patients with persistent atrial fibrillation (AF). MATERIALS AND METHODS. Nineteen patients (11 males and 8 females, mean age 47.46±9.92 years) with persistent idiopathic AF underwent preoperative complete clinical and instrumental examination. 99mTc-pyrphotech SPECT was performed to identify foci of myocardial inflammatory changes. After completing 99mTC-pyrphotech scanning, resting myocardial perfusion scintigraphy with 99mTC-methoxyisobutylisonitrile (99mTc-MIBI) was performed in accordance with the standard protocol. The scintigrams obtained in both studies were then combined using the applied programs Jet Stream Workspace Release 2.5 (Philips) and the application Fusion. During invasive intervention, endomyocardial samples were intraoperatively taken from all the patients for histological and immunohistochemical examinations. RESULTS. Abnormal 99mTc-pyrphotech myocardial accumulation was found in 7 (36.8%) of the examinees, multiple foci in 3 cases and single foci in 4. Analysis of perfusion scintigrams indicated that the mean abnormal accumulation of 99mTc-MIBI in the left ventricle was 3.75±0.88% (maximum 9%).Histological examination of endomyocardial samples from 19 patients with persistent AF verified myocarditis in 4 (21%) patients and myocardial sclerosis concurrent with other abnormalities in 15 (78.9%) patients. CONCLUSION. Latent lymphocytic or polymorphic cellular myocarditis of viral etiology is a cause of idiopathic AF in 20% of the cases. 99mTc-pyrphotech scintigraphy may be one of the primary noninvasive diagnostic techniques for the detection of myocardial inflammation in this form of arrhythmia.https://ter-arkhiv.ru/0040-3660/article/view/31577myocarditismyocardial scintigraphyatrial fibrillation |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
S I Sazonova Iu B Lishmanov R E Batalov S V Popov Iu N Il'iushenkova Iu V Rogovskaia M Z Idrisov |
spellingShingle |
S I Sazonova Iu B Lishmanov R E Batalov S V Popov Iu N Il'iushenkova Iu V Rogovskaia M Z Idrisov Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation Терапевтический архив myocarditis myocardial scintigraphy atrial fibrillation |
author_facet |
S I Sazonova Iu B Lishmanov R E Batalov S V Popov Iu N Il'iushenkova Iu V Rogovskaia M Z Idrisov |
author_sort |
S I Sazonova |
title |
Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation |
title_short |
Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation |
title_full |
Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation |
title_fullStr |
Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation |
title_full_unstemmed |
Capabilities of 99mTc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation |
title_sort |
capabilities of 99mtc-pyrphotech single-photon emission computed tomography in combination with myocardial perfusion scintigraphy in the evaluation of inflammatory changes in the heart of patients with persistent atrial fibrillation |
publisher |
"Consilium Medicum" Publishing house |
series |
Терапевтический архив |
issn |
0040-3660 2309-5342 |
publishDate |
2014-12-01 |
description |
AIM. To estimate the capabilities of 99mTc-pyrphotech single-photon emission computed tomography (SPECT) in the diagnosis of myocardial inflammatory changes in patients with persistent atrial fibrillation (AF). MATERIALS AND METHODS. Nineteen patients (11 males and 8 females, mean age 47.46±9.92 years) with persistent idiopathic AF underwent preoperative complete clinical and instrumental examination. 99mTc-pyrphotech SPECT was performed to identify foci of myocardial inflammatory changes. After completing 99mTC-pyrphotech scanning, resting myocardial perfusion scintigraphy with 99mTC-methoxyisobutylisonitrile (99mTc-MIBI) was performed in accordance with the standard protocol. The scintigrams obtained in both studies were then combined using the applied programs Jet Stream Workspace Release 2.5 (Philips) and the application Fusion. During invasive intervention, endomyocardial samples were intraoperatively taken from all the patients for histological and immunohistochemical examinations. RESULTS. Abnormal 99mTc-pyrphotech myocardial accumulation was found in 7 (36.8%) of the examinees, multiple foci in 3 cases and single foci in 4. Analysis of perfusion scintigrams indicated that the mean abnormal accumulation of 99mTc-MIBI in the left ventricle was 3.75±0.88% (maximum 9%).Histological examination of endomyocardial samples from 19 patients with persistent AF verified myocarditis in 4 (21%) patients and myocardial sclerosis concurrent with other abnormalities in 15 (78.9%) patients. CONCLUSION. Latent lymphocytic or polymorphic cellular myocarditis of viral etiology is a cause of idiopathic AF in 20% of the cases. 99mTc-pyrphotech scintigraphy may be one of the primary noninvasive diagnostic techniques for the detection of myocardial inflammation in this form of arrhythmia. |
topic |
myocarditis myocardial scintigraphy atrial fibrillation |
url |
https://ter-arkhiv.ru/0040-3660/article/view/31577 |
work_keys_str_mv |
AT sisazonova capabilitiesof99mtcpyrphotechsinglephotonemissioncomputedtomographyincombinationwithmyocardialperfusionscintigraphyintheevaluationofinflammatorychangesintheheartofpatientswithpersistentatrialfibrillation AT iublishmanov capabilitiesof99mtcpyrphotechsinglephotonemissioncomputedtomographyincombinationwithmyocardialperfusionscintigraphyintheevaluationofinflammatorychangesintheheartofpatientswithpersistentatrialfibrillation AT rebatalov capabilitiesof99mtcpyrphotechsinglephotonemissioncomputedtomographyincombinationwithmyocardialperfusionscintigraphyintheevaluationofinflammatorychangesintheheartofpatientswithpersistentatrialfibrillation AT svpopov capabilitiesof99mtcpyrphotechsinglephotonemissioncomputedtomographyincombinationwithmyocardialperfusionscintigraphyintheevaluationofinflammatorychangesintheheartofpatientswithpersistentatrialfibrillation AT iuniliushenkova capabilitiesof99mtcpyrphotechsinglephotonemissioncomputedtomographyincombinationwithmyocardialperfusionscintigraphyintheevaluationofinflammatorychangesintheheartofpatientswithpersistentatrialfibrillation AT iuvrogovskaia capabilitiesof99mtcpyrphotechsinglephotonemissioncomputedtomographyincombinationwithmyocardialperfusionscintigraphyintheevaluationofinflammatorychangesintheheartofpatientswithpersistentatrialfibrillation AT mzidrisov capabilitiesof99mtcpyrphotechsinglephotonemissioncomputedtomographyincombinationwithmyocardialperfusionscintigraphyintheevaluationofinflammatorychangesintheheartofpatientswithpersistentatrialfibrillation |
_version_ |
1724566043187216384 |