Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference
The existing methods for estimating harmonic impedance usually assume that harmonic impedance is constant in a measurement period. However, for a variety of practical reasons, such as the load change of power grid, utility harmonic impedance may be changed. So a reasonable hypothesis is that utility...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2020-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9238000/ |
id |
doaj-7da9cc7cdff14201a35c00e281e8f82f |
---|---|
record_format |
Article |
spelling |
doaj-7da9cc7cdff14201a35c00e281e8f82f2021-03-30T03:57:02ZengIEEEIEEE Access2169-35362020-01-01820738920739610.1109/ACCESS.2020.30333889238000Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance DifferenceFangwei Xu0https://orcid.org/0000-0002-8274-346XChuan Wang1https://orcid.org/0000-0001-9594-6461Qin Shu2https://orcid.org/0000-0002-7225-6043Zhiquan Ma3Hongru Zheng4https://orcid.org/0000-0001-7607-7977Anqing Peng5College of Electrical Engineering, Sichuan University, Chengdu, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaState Grid Zhejiang Electric Power Research Institute, Hangzhou, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaThe existing methods for estimating harmonic impedance usually assume that harmonic impedance is constant in a measurement period. However, for a variety of practical reasons, such as the load change of power grid, utility harmonic impedance may be changed. So a reasonable hypothesis is that utility harmonic impedance is time-varying, but the variation of the impedance is not large at adjacent sampling time. Thus, this paper proposes a novel method to estimate utility harmonic impedance by taking the criterion of minimum norm of impedance differences at adjacent sampling times with a measurement period. According to the proposed criterion, an objective function is built with the norm of the harmonic impedance differences and utility harmonic voltage differences of adjacent moments. And then, the utility harmonic impedance can be obtained by minimizing the objective function. The proposed method has high accuracy even while background harmonic emission level is high and harmonic impedance of customer side is not much larger than that of utility side. The effectiveness is verified by the simulation and field cases. In the simulation, the estimation errors of most cases are within 10% and the maximum error is not exceed 16%.https://ieeexplore.ieee.org/document/9238000/Harmonic impedanceutility harmonic voltagebackground harmonicimpedance differencenormobjective function |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Fangwei Xu Chuan Wang Qin Shu Zhiquan Ma Hongru Zheng Anqing Peng |
spellingShingle |
Fangwei Xu Chuan Wang Qin Shu Zhiquan Ma Hongru Zheng Anqing Peng Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference IEEE Access Harmonic impedance utility harmonic voltage background harmonic impedance difference norm objective function |
author_facet |
Fangwei Xu Chuan Wang Qin Shu Zhiquan Ma Hongru Zheng Anqing Peng |
author_sort |
Fangwei Xu |
title |
Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference |
title_short |
Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference |
title_full |
Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference |
title_fullStr |
Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference |
title_full_unstemmed |
Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference |
title_sort |
study on the estimation of utility harmonic impedance based on minimum norm of impedance difference |
publisher |
IEEE |
series |
IEEE Access |
issn |
2169-3536 |
publishDate |
2020-01-01 |
description |
The existing methods for estimating harmonic impedance usually assume that harmonic impedance is constant in a measurement period. However, for a variety of practical reasons, such as the load change of power grid, utility harmonic impedance may be changed. So a reasonable hypothesis is that utility harmonic impedance is time-varying, but the variation of the impedance is not large at adjacent sampling time. Thus, this paper proposes a novel method to estimate utility harmonic impedance by taking the criterion of minimum norm of impedance differences at adjacent sampling times with a measurement period. According to the proposed criterion, an objective function is built with the norm of the harmonic impedance differences and utility harmonic voltage differences of adjacent moments. And then, the utility harmonic impedance can be obtained by minimizing the objective function. The proposed method has high accuracy even while background harmonic emission level is high and harmonic impedance of customer side is not much larger than that of utility side. The effectiveness is verified by the simulation and field cases. In the simulation, the estimation errors of most cases are within 10% and the maximum error is not exceed 16%. |
topic |
Harmonic impedance utility harmonic voltage background harmonic impedance difference norm objective function |
url |
https://ieeexplore.ieee.org/document/9238000/ |
work_keys_str_mv |
AT fangweixu studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference AT chuanwang studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference AT qinshu studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference AT zhiquanma studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference AT hongruzheng studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference AT anqingpeng studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference |
_version_ |
1724182637616037888 |