Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference

The existing methods for estimating harmonic impedance usually assume that harmonic impedance is constant in a measurement period. However, for a variety of practical reasons, such as the load change of power grid, utility harmonic impedance may be changed. So a reasonable hypothesis is that utility...

Full description

Bibliographic Details
Main Authors: Fangwei Xu, Chuan Wang, Qin Shu, Zhiquan Ma, Hongru Zheng, Anqing Peng
Format: Article
Language:English
Published: IEEE 2020-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9238000/
id doaj-7da9cc7cdff14201a35c00e281e8f82f
record_format Article
spelling doaj-7da9cc7cdff14201a35c00e281e8f82f2021-03-30T03:57:02ZengIEEEIEEE Access2169-35362020-01-01820738920739610.1109/ACCESS.2020.30333889238000Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance DifferenceFangwei Xu0https://orcid.org/0000-0002-8274-346XChuan Wang1https://orcid.org/0000-0001-9594-6461Qin Shu2https://orcid.org/0000-0002-7225-6043Zhiquan Ma3Hongru Zheng4https://orcid.org/0000-0001-7607-7977Anqing Peng5College of Electrical Engineering, Sichuan University, Chengdu, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaState Grid Zhejiang Electric Power Research Institute, Hangzhou, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu, ChinaThe existing methods for estimating harmonic impedance usually assume that harmonic impedance is constant in a measurement period. However, for a variety of practical reasons, such as the load change of power grid, utility harmonic impedance may be changed. So a reasonable hypothesis is that utility harmonic impedance is time-varying, but the variation of the impedance is not large at adjacent sampling time. Thus, this paper proposes a novel method to estimate utility harmonic impedance by taking the criterion of minimum norm of impedance differences at adjacent sampling times with a measurement period. According to the proposed criterion, an objective function is built with the norm of the harmonic impedance differences and utility harmonic voltage differences of adjacent moments. And then, the utility harmonic impedance can be obtained by minimizing the objective function. The proposed method has high accuracy even while background harmonic emission level is high and harmonic impedance of customer side is not much larger than that of utility side. The effectiveness is verified by the simulation and field cases. In the simulation, the estimation errors of most cases are within 10% and the maximum error is not exceed 16%.https://ieeexplore.ieee.org/document/9238000/Harmonic impedanceutility harmonic voltagebackground harmonicimpedance differencenormobjective function
collection DOAJ
language English
format Article
sources DOAJ
author Fangwei Xu
Chuan Wang
Qin Shu
Zhiquan Ma
Hongru Zheng
Anqing Peng
spellingShingle Fangwei Xu
Chuan Wang
Qin Shu
Zhiquan Ma
Hongru Zheng
Anqing Peng
Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference
IEEE Access
Harmonic impedance
utility harmonic voltage
background harmonic
impedance difference
norm
objective function
author_facet Fangwei Xu
Chuan Wang
Qin Shu
Zhiquan Ma
Hongru Zheng
Anqing Peng
author_sort Fangwei Xu
title Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference
title_short Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference
title_full Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference
title_fullStr Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference
title_full_unstemmed Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference
title_sort study on the estimation of utility harmonic impedance based on minimum norm of impedance difference
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2020-01-01
description The existing methods for estimating harmonic impedance usually assume that harmonic impedance is constant in a measurement period. However, for a variety of practical reasons, such as the load change of power grid, utility harmonic impedance may be changed. So a reasonable hypothesis is that utility harmonic impedance is time-varying, but the variation of the impedance is not large at adjacent sampling time. Thus, this paper proposes a novel method to estimate utility harmonic impedance by taking the criterion of minimum norm of impedance differences at adjacent sampling times with a measurement period. According to the proposed criterion, an objective function is built with the norm of the harmonic impedance differences and utility harmonic voltage differences of adjacent moments. And then, the utility harmonic impedance can be obtained by minimizing the objective function. The proposed method has high accuracy even while background harmonic emission level is high and harmonic impedance of customer side is not much larger than that of utility side. The effectiveness is verified by the simulation and field cases. In the simulation, the estimation errors of most cases are within 10% and the maximum error is not exceed 16%.
topic Harmonic impedance
utility harmonic voltage
background harmonic
impedance difference
norm
objective function
url https://ieeexplore.ieee.org/document/9238000/
work_keys_str_mv AT fangweixu studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference
AT chuanwang studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference
AT qinshu studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference
AT zhiquanma studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference
AT hongruzheng studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference
AT anqingpeng studyontheestimationofutilityharmonicimpedancebasedonminimumnormofimpedancedifference
_version_ 1724182637616037888