Monitoring chest compression quality during cardiopulmonary resuscitation: Proof-of-concept of a single accelerometer-based feedback algorithm.

The use of real-time feedback systems to guide rescuers during cardiopulmonary resuscitation (CPR) significantly contributes to improve adherence to published resuscitation guidelines. Recently, we designed a novel method for computing depth and rate of chest compressions relying solely on the spect...

Full description

Bibliographic Details
Main Authors: Digna María González-Otero, Jesus María Ruiz, Sofía Ruiz de Gauna, Jose Julio Gutiérrez, Mohamud Daya, James Knox Russell, Izaskun Azcarate, Mikel Leturiondo
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2018-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5812631?pdf=render
id doaj-7d9bbf93a2e34b1e8394149589068955
record_format Article
spelling doaj-7d9bbf93a2e34b1e83941495890689552020-11-25T01:56:49ZengPublic Library of Science (PLoS)PLoS ONE1932-62032018-01-01132e019281010.1371/journal.pone.0192810Monitoring chest compression quality during cardiopulmonary resuscitation: Proof-of-concept of a single accelerometer-based feedback algorithm.Digna María González-OteroJesus María RuizSofía Ruiz de GaunaJose Julio GutiérrezMohamud DayaJames Knox RussellIzaskun AzcarateMikel LeturiondoThe use of real-time feedback systems to guide rescuers during cardiopulmonary resuscitation (CPR) significantly contributes to improve adherence to published resuscitation guidelines. Recently, we designed a novel method for computing depth and rate of chest compressions relying solely on the spectral analysis of chest acceleration. That method was extensively tested in a simulated manikin scenario. The purpose of this study is to report the results of this method as tested in human out-of-hospital cardiac arrest (OHCA) cases.The algorithm was evaluated retrospectively with seventy five OHCA episodes recorded by monitor-defibrillators equipped with a CPR feedback device. The acceleration signal and the compression signal computed by the CPR feedback device were stored in each episode. The algorithm was continuously applied to the acceleration signals. The depth and rate values estimated every 2-s from the acceleration data were compared to the reference values obtained from the compression signal. The performance of the algorithm was assesed in terms of the sensitivity and positive predictive value (PPV) for detecting compressions and in terms of its accuracy through the analysis of measurement error.The algorithm reported a global sensitivity and PPV of 99.98% and 99.79%, respectively. The median (P75) unsigned error in depth and rate was 0.9 (1.7) mm and 1.0 (1.7) cpm, respectively. In 95% of the analyzed 2-s windows the error was below 3.5 mm and 3.1 cpm, respectively.The CPR feedback algorithm proved to be reliable and accurate when tested retrospectively with human OHCA episodes. A new CPR feedback device based on this algorithm could be helpful in the resuscitation field.http://europepmc.org/articles/PMC5812631?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Digna María González-Otero
Jesus María Ruiz
Sofía Ruiz de Gauna
Jose Julio Gutiérrez
Mohamud Daya
James Knox Russell
Izaskun Azcarate
Mikel Leturiondo
spellingShingle Digna María González-Otero
Jesus María Ruiz
Sofía Ruiz de Gauna
Jose Julio Gutiérrez
Mohamud Daya
James Knox Russell
Izaskun Azcarate
Mikel Leturiondo
Monitoring chest compression quality during cardiopulmonary resuscitation: Proof-of-concept of a single accelerometer-based feedback algorithm.
PLoS ONE
author_facet Digna María González-Otero
Jesus María Ruiz
Sofía Ruiz de Gauna
Jose Julio Gutiérrez
Mohamud Daya
James Knox Russell
Izaskun Azcarate
Mikel Leturiondo
author_sort Digna María González-Otero
title Monitoring chest compression quality during cardiopulmonary resuscitation: Proof-of-concept of a single accelerometer-based feedback algorithm.
title_short Monitoring chest compression quality during cardiopulmonary resuscitation: Proof-of-concept of a single accelerometer-based feedback algorithm.
title_full Monitoring chest compression quality during cardiopulmonary resuscitation: Proof-of-concept of a single accelerometer-based feedback algorithm.
title_fullStr Monitoring chest compression quality during cardiopulmonary resuscitation: Proof-of-concept of a single accelerometer-based feedback algorithm.
title_full_unstemmed Monitoring chest compression quality during cardiopulmonary resuscitation: Proof-of-concept of a single accelerometer-based feedback algorithm.
title_sort monitoring chest compression quality during cardiopulmonary resuscitation: proof-of-concept of a single accelerometer-based feedback algorithm.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2018-01-01
description The use of real-time feedback systems to guide rescuers during cardiopulmonary resuscitation (CPR) significantly contributes to improve adherence to published resuscitation guidelines. Recently, we designed a novel method for computing depth and rate of chest compressions relying solely on the spectral analysis of chest acceleration. That method was extensively tested in a simulated manikin scenario. The purpose of this study is to report the results of this method as tested in human out-of-hospital cardiac arrest (OHCA) cases.The algorithm was evaluated retrospectively with seventy five OHCA episodes recorded by monitor-defibrillators equipped with a CPR feedback device. The acceleration signal and the compression signal computed by the CPR feedback device were stored in each episode. The algorithm was continuously applied to the acceleration signals. The depth and rate values estimated every 2-s from the acceleration data were compared to the reference values obtained from the compression signal. The performance of the algorithm was assesed in terms of the sensitivity and positive predictive value (PPV) for detecting compressions and in terms of its accuracy through the analysis of measurement error.The algorithm reported a global sensitivity and PPV of 99.98% and 99.79%, respectively. The median (P75) unsigned error in depth and rate was 0.9 (1.7) mm and 1.0 (1.7) cpm, respectively. In 95% of the analyzed 2-s windows the error was below 3.5 mm and 3.1 cpm, respectively.The CPR feedback algorithm proved to be reliable and accurate when tested retrospectively with human OHCA episodes. A new CPR feedback device based on this algorithm could be helpful in the resuscitation field.
url http://europepmc.org/articles/PMC5812631?pdf=render
work_keys_str_mv AT dignamariagonzalezotero monitoringchestcompressionqualityduringcardiopulmonaryresuscitationproofofconceptofasingleaccelerometerbasedfeedbackalgorithm
AT jesusmariaruiz monitoringchestcompressionqualityduringcardiopulmonaryresuscitationproofofconceptofasingleaccelerometerbasedfeedbackalgorithm
AT sofiaruizdegauna monitoringchestcompressionqualityduringcardiopulmonaryresuscitationproofofconceptofasingleaccelerometerbasedfeedbackalgorithm
AT josejuliogutierrez monitoringchestcompressionqualityduringcardiopulmonaryresuscitationproofofconceptofasingleaccelerometerbasedfeedbackalgorithm
AT mohamuddaya monitoringchestcompressionqualityduringcardiopulmonaryresuscitationproofofconceptofasingleaccelerometerbasedfeedbackalgorithm
AT jamesknoxrussell monitoringchestcompressionqualityduringcardiopulmonaryresuscitationproofofconceptofasingleaccelerometerbasedfeedbackalgorithm
AT izaskunazcarate monitoringchestcompressionqualityduringcardiopulmonaryresuscitationproofofconceptofasingleaccelerometerbasedfeedbackalgorithm
AT mikelleturiondo monitoringchestcompressionqualityduringcardiopulmonaryresuscitationproofofconceptofasingleaccelerometerbasedfeedbackalgorithm
_version_ 1724977354949787648