Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).

Non-invasive sampling techniques are increasingly being used to monitor glucocorticoids, such as cortisol, as indicators of stressor load and fitness in zoo and wildlife conservation, research and medicine. For cetaceans, exhaled breath condensate (blow) provides a unique sampling matrix for such pu...

Full description

Bibliographic Details
Main Authors: Laura A Thompson, Tracey R Spoon, Caroline E C Goertz, Roderick C Hobbs, Tracy A Romano
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2014-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4252093?pdf=render
id doaj-7d4d258e24ae46f99ac811185e98dcf6
record_format Article
spelling doaj-7d4d258e24ae46f99ac811185e98dcf62020-11-25T02:37:10ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-01912e11406210.1371/journal.pone.0114062Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).Laura A ThompsonTracey R SpoonCaroline E C GoertzRoderick C HobbsTracy A RomanoNon-invasive sampling techniques are increasingly being used to monitor glucocorticoids, such as cortisol, as indicators of stressor load and fitness in zoo and wildlife conservation, research and medicine. For cetaceans, exhaled breath condensate (blow) provides a unique sampling matrix for such purposes. The purpose of this work was to develop an appropriate collection methodology and validate the use of a commercially available EIA for measuring cortisol in blow samples collected from belugas (Delphinapterus leucas). Nitex membrane stretched over a petri dish provided the optimal method for collecting blow. A commercially available cortisol EIA for measuring human cortisol (detection limit 35 pg ml-1) was adapted and validated for beluga cortisol using tests of parallelism, accuracy and recovery. Blow samples were collected from aquarium belugas during monthly health checks and during out of water examination, as well as from wild belugas. Two aquarium belugas showed increased blow cortisol between baseline samples and 30 minutes out of water (Baseline, 0.21 and 0.04 µg dl-1; 30 minutes, 0.95 and 0.14 µg dl-1). Six wild belugas also showed increases in blow cortisol between pre and post 1.5 hour examination (Pre 0.03, 0.23, 0.13, 0.19, 0.13, 0.04 µg dl-1, Post 0.60, 0.31, 0.36, 0.24, 0.14, 0.16 µg dl-1). Though this methodology needs further investigation, this study suggests that blow sampling is a good candidate for non-invasive monitoring of cortisol in belugas. It can be collected from both wild and aquarium animals efficiently for the purposes of health monitoring and research, and may ultimately be useful in obtaining data on wild populations, including endangered species, which are difficult to handle directly.http://europepmc.org/articles/PMC4252093?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Laura A Thompson
Tracey R Spoon
Caroline E C Goertz
Roderick C Hobbs
Tracy A Romano
spellingShingle Laura A Thompson
Tracey R Spoon
Caroline E C Goertz
Roderick C Hobbs
Tracy A Romano
Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).
PLoS ONE
author_facet Laura A Thompson
Tracey R Spoon
Caroline E C Goertz
Roderick C Hobbs
Tracy A Romano
author_sort Laura A Thompson
title Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).
title_short Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).
title_full Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).
title_fullStr Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).
title_full_unstemmed Blow collection as a non-invasive method for measuring cortisol in the beluga (Delphinapterus leucas).
title_sort blow collection as a non-invasive method for measuring cortisol in the beluga (delphinapterus leucas).
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2014-01-01
description Non-invasive sampling techniques are increasingly being used to monitor glucocorticoids, such as cortisol, as indicators of stressor load and fitness in zoo and wildlife conservation, research and medicine. For cetaceans, exhaled breath condensate (blow) provides a unique sampling matrix for such purposes. The purpose of this work was to develop an appropriate collection methodology and validate the use of a commercially available EIA for measuring cortisol in blow samples collected from belugas (Delphinapterus leucas). Nitex membrane stretched over a petri dish provided the optimal method for collecting blow. A commercially available cortisol EIA for measuring human cortisol (detection limit 35 pg ml-1) was adapted and validated for beluga cortisol using tests of parallelism, accuracy and recovery. Blow samples were collected from aquarium belugas during monthly health checks and during out of water examination, as well as from wild belugas. Two aquarium belugas showed increased blow cortisol between baseline samples and 30 minutes out of water (Baseline, 0.21 and 0.04 µg dl-1; 30 minutes, 0.95 and 0.14 µg dl-1). Six wild belugas also showed increases in blow cortisol between pre and post 1.5 hour examination (Pre 0.03, 0.23, 0.13, 0.19, 0.13, 0.04 µg dl-1, Post 0.60, 0.31, 0.36, 0.24, 0.14, 0.16 µg dl-1). Though this methodology needs further investigation, this study suggests that blow sampling is a good candidate for non-invasive monitoring of cortisol in belugas. It can be collected from both wild and aquarium animals efficiently for the purposes of health monitoring and research, and may ultimately be useful in obtaining data on wild populations, including endangered species, which are difficult to handle directly.
url http://europepmc.org/articles/PMC4252093?pdf=render
work_keys_str_mv AT lauraathompson blowcollectionasanoninvasivemethodformeasuringcortisolinthebelugadelphinapterusleucas
AT traceyrspoon blowcollectionasanoninvasivemethodformeasuringcortisolinthebelugadelphinapterusleucas
AT carolineecgoertz blowcollectionasanoninvasivemethodformeasuringcortisolinthebelugadelphinapterusleucas
AT roderickchobbs blowcollectionasanoninvasivemethodformeasuringcortisolinthebelugadelphinapterusleucas
AT tracyaromano blowcollectionasanoninvasivemethodformeasuringcortisolinthebelugadelphinapterusleucas
_version_ 1724796273635098624