Arnebia euchroma ointment can reduce abdominal fat thickness and abdominal circumference of overweight women: A randomized controlled study

Background: Obesity is a worldwide health problem which is associated with a lot of complications. One of these comorbidities is the metabolic syndrome that is in correlation with abdominal fat thickness and waist circumference. Various methods were used to reduce abdominal fat thickness such as lip...

Full description

Bibliographic Details
Main Authors: Mansour Siavash, Mohsen Naseri, Mojgan Rahimi
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Journal of Research in Medical Sciences
Subjects:
Online Access:http://www.jmsjournal.net/article.asp?issn=1735-1995;year=2016;volume=21;issue=1;spage=63;epage=63;aulast=Siavash
Description
Summary:Background: Obesity is a worldwide health problem which is associated with a lot of complications. One of these comorbidities is the metabolic syndrome that is in correlation with abdominal fat thickness and waist circumference. Various methods were used to reduce abdominal fat thickness such as liposuction. A noninvasive method is the topical agent. In this study, we investigated the effectiveness of Arnebia euchroma (AE) ointment on the abdominal fat thickness. Materials and Methods: This study was a double-blind clinical trial which was done at the endocrinology clinic in Khorshid Hospital, Isfahan, Iran, in 2014. After explaining the procedure and obtaining informed consent, the candidates were randomly divided into the case and control groups. The participants of the case and control groups applied AE ointment or placebo for 6 weeks on their abdominal area. Body mass index, waist and buttock circumference, and abdominal fat thickness were measured in both case and control groups at their first visit and then at the next 2, 4, and 6 weeks. We used t-test for comparing parametric variables between groups, paired t-test for changes from baseline to final, and repeated measure ANOVA for changes at different steps. Results: Sixty female candidates participated in this study (thirty in each group). Ten patients left the study and fifty participants finished the trial. At the end of the study, participants had a significant weight loss (2.96 ± 1.6 kg, P < 0.001) that was slightly more in the case group (3.15 ± 1.5 kg vs. 2.75 ± 1.7, P = 0.375). Abdominal circumference also decreased significantly in the participants (11.3 ± 6.7 cm, P < 0.001), but the changes were more significant in the case group (13.9 vs. 6.5 cm, P = 0.004). Similarly, abdominal fat thickness decreased significantly in the participants (2.3 ± 1.1 cm, P < 0.001), although changes were not significantly different between two groups (2.53 vs. 2.04 cm, P = 0.139). Conclusion: Topical AE ointment can reduce the abdominal fat thickness as well as the waist circumference without causing any side effect.
ISSN:1735-1995