Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in Buildings

This work investigates the light illumination intensity, light transmission performance, light distribution on the floor, and daylight factor of vertical light hollow tubes at various incident elevation angles of a light source. The light tubes were made from commercial aluminum alloy sheets and com...

Full description

Bibliographic Details
Main Authors: Jiraphorn Mahawan, Atthakorn Thongtha
Format: Article
Language:English
Published: MDPI AG 2021-01-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/2/260
id doaj-7cfae2eacd8842e7a6d100010c8d1046
record_format Article
spelling doaj-7cfae2eacd8842e7a6d100010c8d10462021-01-07T00:00:39ZengMDPI AGEnergies1996-10732021-01-011426026010.3390/en14020260Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in BuildingsJiraphorn Mahawan0Atthakorn Thongtha1Department of Physics, Faculty of Science, Naresuan University, Phitsanulok 65000, ThailandDepartment of Physics, Faculty of Science, Naresuan University, Phitsanulok 65000, ThailandThis work investigates the light illumination intensity, light transmission performance, light distribution on the floor, and daylight factor of vertical light hollow tubes at various incident elevation angles of a light source. The light tubes were made from commercial aluminum alloy sheets and commercial zinc alloy sheets to investigate internal illuminance for buildings and reducing the demand of electrical energy from artificial lighting. The vertical light tubes with a constant length of 0.5 m and diameters of 0.20, 0.25, and 0.30 m were designed in a testing room model, with dimensions of 1 m × 1 m × 1 m. A 20-W light-emitting diode (LED) lamp was used as the light source for the lighting simulations, which was placed away from the top of the light tube. The incident elevation angle of the light source was changed between 0° and 80° with 5° increments. It was found that the elevation angle of the incidence light had an influence on the light intensity distribution on both ends of light tube. The average illuminance performance of both material types increased with an increase of the incidence angle from 0° to 80° and an increase of the tube diameter from 0.20 m to 0.30 m. The commercial aluminum alloy tube promotes greater light transmission and daylight factor when compared with the commercial zinc alloy tube in each condition. This illuminance measurement demonstrates that the light tube could be included in the lighting systems of some deeper or windowless areas of buildings to decrease the demand of energy consumption in the lighting of buildings.https://www.mdpi.com/1996-1073/14/2/260daylightlight pipelight transmissiondaylight factorillumination
collection DOAJ
language English
format Article
sources DOAJ
author Jiraphorn Mahawan
Atthakorn Thongtha
spellingShingle Jiraphorn Mahawan
Atthakorn Thongtha
Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in Buildings
Energies
daylight
light pipe
light transmission
daylight factor
illumination
author_facet Jiraphorn Mahawan
Atthakorn Thongtha
author_sort Jiraphorn Mahawan
title Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in Buildings
title_short Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in Buildings
title_full Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in Buildings
title_fullStr Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in Buildings
title_full_unstemmed Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in Buildings
title_sort experimental investigation of illumination performance of hollow light pipe for energy consumption reduction in buildings
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2021-01-01
description This work investigates the light illumination intensity, light transmission performance, light distribution on the floor, and daylight factor of vertical light hollow tubes at various incident elevation angles of a light source. The light tubes were made from commercial aluminum alloy sheets and commercial zinc alloy sheets to investigate internal illuminance for buildings and reducing the demand of electrical energy from artificial lighting. The vertical light tubes with a constant length of 0.5 m and diameters of 0.20, 0.25, and 0.30 m were designed in a testing room model, with dimensions of 1 m × 1 m × 1 m. A 20-W light-emitting diode (LED) lamp was used as the light source for the lighting simulations, which was placed away from the top of the light tube. The incident elevation angle of the light source was changed between 0° and 80° with 5° increments. It was found that the elevation angle of the incidence light had an influence on the light intensity distribution on both ends of light tube. The average illuminance performance of both material types increased with an increase of the incidence angle from 0° to 80° and an increase of the tube diameter from 0.20 m to 0.30 m. The commercial aluminum alloy tube promotes greater light transmission and daylight factor when compared with the commercial zinc alloy tube in each condition. This illuminance measurement demonstrates that the light tube could be included in the lighting systems of some deeper or windowless areas of buildings to decrease the demand of energy consumption in the lighting of buildings.
topic daylight
light pipe
light transmission
daylight factor
illumination
url https://www.mdpi.com/1996-1073/14/2/260
work_keys_str_mv AT jiraphornmahawan experimentalinvestigationofilluminationperformanceofhollowlightpipeforenergyconsumptionreductioninbuildings
AT atthakornthongtha experimentalinvestigationofilluminationperformanceofhollowlightpipeforenergyconsumptionreductioninbuildings
_version_ 1724347111716159488