Using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system

The article considers the structure and principle of operation of the weapon stabilization system, which is technically a set of sensors and a computer system connected to the gun drive. The stabilization system ensures the constancy of the angles between the axes of the fixed coordinate system and...

Full description

Bibliographic Details
Main Authors: О.М. Bezvesilna, А.H. Tkachuk, A.A. Humeniuk, V.М. Yanchuk, О.О. Dobrzhanskyi
Format: Article
Language:English
Published: Zhytomyr Polytechnic State University 2020-06-01
Series:Технічна інженерія
Subjects:
Online Access:http://ten.ztu.edu.ua/article/view/206088/206463
id doaj-7ce1559244964c9b8fdb117241ca8815
record_format Article
spelling doaj-7ce1559244964c9b8fdb117241ca88152020-11-25T02:48:05ZengZhytomyr Polytechnic State UniversityТехнічна інженерія2706-58472707-96192020-06-0118515816410.26642/ten-2020-1(85)-158-164Using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system О.М. Bezvesilnahttps://orcid.org/0000-0002-6951-1242А.H. Tkachukhttps://orcid.org/0000-0003-2466-6299A.A. Humeniukhttps://orcid.org/0000-0002-5744-4599V.М. Yanchukhttps://orcid.org/0000-0002-6715-4667 О.О. Dobrzhanskyi https://orcid.org/0000-0002-4330-0287The article considers the structure and principle of operation of the weapon stabilization system, which is technically a set of sensors and a computer system connected to the gun drive. The stabilization system ensures the constancy of the angles between the axes of the fixed coordinate system and the axes rigidly connected to the object of stabilization. It is established that the quality of armament stabilization systems is evaluated by the following indicators, both in stabilization mode and in guidance mode: stability, accuracy of weapon stabilization, stabilization quality, guidance speed and nature of distribution on the angle of rotation of the control panel, stabilizer time, continuous operation stabilizer, reliability of operation and the nature and timing of transients when working out the angles of inconsistency. The accuracy of stabilization is the main indicator that characterizes the operation of the fire control system in stabilization mode. External disturbances caused by continuous random oscillations of the hull by mobile light armored vehicles cause deviation of the stabilized armament from the specified direction of guidance. A new piezoelectric sensitive element of the weapon stabilization system and the expediency of using the two-channel method to increase its accuracy are considered. It is established that due to the use of additionally introduced into the design of the sensitive piezoelectric element of the second measurement channel, there is no error in its output signal from the influence of vertical acceleration, from residual non-identical designs of identical piezoelectric plates and masses, from temperature, humidity and external pressure. environment (ie instrumental errors), which can be significant.http://ten.ztu.edu.ua/article/view/206088/206463piezoelectric sensing elementaccuracyerrordual channel
collection DOAJ
language English
format Article
sources DOAJ
author О.М. Bezvesilna
А.H. Tkachuk
A.A. Humeniuk
V.М. Yanchuk
О.О. Dobrzhanskyi
spellingShingle О.М. Bezvesilna
А.H. Tkachuk
A.A. Humeniuk
V.М. Yanchuk
О.О. Dobrzhanskyi
Using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system
Технічна інженерія
piezoelectric sensing element
accuracy
error
dual channel
author_facet О.М. Bezvesilna
А.H. Tkachuk
A.A. Humeniuk
V.М. Yanchuk
О.О. Dobrzhanskyi
author_sort О.М. Bezvesilna
title Using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system
title_short Using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system
title_full Using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system
title_fullStr Using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system
title_full_unstemmed Using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system
title_sort using the two-channel method to increase the accuracy of a new piezoelectric sensitive element of the weapon stabilization system
publisher Zhytomyr Polytechnic State University
series Технічна інженерія
issn 2706-5847
2707-9619
publishDate 2020-06-01
description The article considers the structure and principle of operation of the weapon stabilization system, which is technically a set of sensors and a computer system connected to the gun drive. The stabilization system ensures the constancy of the angles between the axes of the fixed coordinate system and the axes rigidly connected to the object of stabilization. It is established that the quality of armament stabilization systems is evaluated by the following indicators, both in stabilization mode and in guidance mode: stability, accuracy of weapon stabilization, stabilization quality, guidance speed and nature of distribution on the angle of rotation of the control panel, stabilizer time, continuous operation stabilizer, reliability of operation and the nature and timing of transients when working out the angles of inconsistency. The accuracy of stabilization is the main indicator that characterizes the operation of the fire control system in stabilization mode. External disturbances caused by continuous random oscillations of the hull by mobile light armored vehicles cause deviation of the stabilized armament from the specified direction of guidance. A new piezoelectric sensitive element of the weapon stabilization system and the expediency of using the two-channel method to increase its accuracy are considered. It is established that due to the use of additionally introduced into the design of the sensitive piezoelectric element of the second measurement channel, there is no error in its output signal from the influence of vertical acceleration, from residual non-identical designs of identical piezoelectric plates and masses, from temperature, humidity and external pressure. environment (ie instrumental errors), which can be significant.
topic piezoelectric sensing element
accuracy
error
dual channel
url http://ten.ztu.edu.ua/article/view/206088/206463
work_keys_str_mv AT ombezvesilna usingthetwochannelmethodtoincreasetheaccuracyofanewpiezoelectricsensitiveelementoftheweaponstabilizationsystem
AT ahtkachuk usingthetwochannelmethodtoincreasetheaccuracyofanewpiezoelectricsensitiveelementoftheweaponstabilizationsystem
AT aahumeniuk usingthetwochannelmethodtoincreasetheaccuracyofanewpiezoelectricsensitiveelementoftheweaponstabilizationsystem
AT vmyanchuk usingthetwochannelmethodtoincreasetheaccuracyofanewpiezoelectricsensitiveelementoftheweaponstabilizationsystem
AT oodobrzhanskyi usingthetwochannelmethodtoincreasetheaccuracyofanewpiezoelectricsensitiveelementoftheweaponstabilizationsystem
_version_ 1724750091135221760