AIM: To observed the clinical effect of twice fluid-gas exchange in vitrectomy for retinal detachment at the equator. <p>METHODS: The retrospective analysis of the 74 cases(74 eyes)with retinal detachment at the equator from January 2014 to September 2015 were reviewed. All these patients were...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2016-06-01
|
Series: | Guoji Yanke Zazhi |
Subjects: | |
Online Access: | http://ies.ijo.cn/cn_publish/2016/6/201606028.pdf |
id |
doaj-7c69a9eda5ca40d6b6c246b6b1d0497a |
---|---|
record_format |
Article |
spelling |
doaj-7c69a9eda5ca40d6b6c246b6b1d0497a2020-11-25T01:50:47ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232016-06-011661113111510.3980/j.issn.1672-5123.2016.6.28Clinical application of twice fluid-gas exchange in vitrectomyAi-Min Yan0Feng-Hua Chen1Kai Peng2Department of Ophthalmology,the First People's Hospital of Guiyang,Guiyang 550002,Guizhou Province,ChinaDepartment of Ophthalmology,the First People's Hospital of Guiyang,Guiyang 550002,Guizhou Province,ChinaDepartment of Ophthalmology,the First People's Hospital of Guiyang,Guiyang 550002,Guizhou Province,ChinaAIM: To observed the clinical effect of twice fluid-gas exchange in vitrectomy for retinal detachment at the equator. <p>METHODS: The retrospective analysis of the 74 cases(74 eyes)with retinal detachment at the equator from January 2014 to September 2015 were reviewed. All these patients were performed standard three channel 23G vitrectomy under a wide angle lens, in which, the 37 cases(37 eyes)were randomly selected and performed single fluid-gas exchange, and the other 37 cases(37 eyes)were performed twice fluid-gas exchange. The intraoperative surgical complications and the postoperative success rate of retinal reposition in 1wk, 1, 3mo after surgery of the two group patients were observed. <p>RESULTS: The intraoperative surgical complication rates of the twice fluid-gas exchange group were less than that of the single fluid-gas exchange group. The postoperative success rate of retinal reposition in the twice fluid-gas exchange group significantly increased in 1wk and 1mo after surgery, and the difference was statistically significant(<i>P</i><0.05). But the postoperative success rate of retinal reposition in 3mo after surgery had no significant difference(<i>P</i>>0.05). <p>CONCLUSION: The twice fluid-gas exchange operation was simple and it was beneficial for beginners to master. The incomplete drainage of the single fluid-gas exchange and the pore drainage in the posterior pole or in the peripheral part of the retina were avoided during the surgery. The intraoperative surgical complication rates were reduced and the postoperative success rate of retinal reposition were improved. This operation method had great application value in clinic.http://ies.ijo.cn/cn_publish/2016/6/201606028.pdffluid-gas exchangeequatorialrhegmatogenous retinal detachmentvitrectomyretinal restorationretinal restoration |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ai-Min Yan Feng-Hua Chen Kai Peng |
spellingShingle |
Ai-Min Yan Feng-Hua Chen Kai Peng Clinical application of twice fluid-gas exchange in vitrectomy Guoji Yanke Zazhi fluid-gas exchange equatorial rhegmatogenous retinal detachment vitrectomy retinal restoration retinal restoration |
author_facet |
Ai-Min Yan Feng-Hua Chen Kai Peng |
author_sort |
Ai-Min Yan |
title |
Clinical application of twice fluid-gas exchange in vitrectomy |
title_short |
Clinical application of twice fluid-gas exchange in vitrectomy |
title_full |
Clinical application of twice fluid-gas exchange in vitrectomy |
title_fullStr |
Clinical application of twice fluid-gas exchange in vitrectomy |
title_full_unstemmed |
Clinical application of twice fluid-gas exchange in vitrectomy |
title_sort |
clinical application of twice fluid-gas exchange in vitrectomy |
publisher |
Press of International Journal of Ophthalmology (IJO PRESS) |
series |
Guoji Yanke Zazhi |
issn |
1672-5123 1672-5123 |
publishDate |
2016-06-01 |
description |
AIM: To observed the clinical effect of twice fluid-gas exchange in vitrectomy for retinal detachment at the equator. <p>METHODS: The retrospective analysis of the 74 cases(74 eyes)with retinal detachment at the equator from January 2014 to September 2015 were reviewed. All these patients were performed standard three channel 23G vitrectomy under a wide angle lens, in which, the 37 cases(37 eyes)were randomly selected and performed single fluid-gas exchange, and the other 37 cases(37 eyes)were performed twice fluid-gas exchange. The intraoperative surgical complications and the postoperative success rate of retinal reposition in 1wk, 1, 3mo after surgery of the two group patients were observed. <p>RESULTS: The intraoperative surgical complication rates of the twice fluid-gas exchange group were less than that of the single fluid-gas exchange group. The postoperative success rate of retinal reposition in the twice fluid-gas exchange group significantly increased in 1wk and 1mo after surgery, and the difference was statistically significant(<i>P</i><0.05). But the postoperative success rate of retinal reposition in 3mo after surgery had no significant difference(<i>P</i>>0.05). <p>CONCLUSION: The twice fluid-gas exchange operation was simple and it was beneficial for beginners to master. The incomplete drainage of the single fluid-gas exchange and the pore drainage in the posterior pole or in the peripheral part of the retina were avoided during the surgery. The intraoperative surgical complication rates were reduced and the postoperative success rate of retinal reposition were improved. This operation method had great application value in clinic. |
topic |
fluid-gas exchange equatorial rhegmatogenous retinal detachment vitrectomy retinal restoration retinal restoration |
url |
http://ies.ijo.cn/cn_publish/2016/6/201606028.pdf |
work_keys_str_mv |
AT aiminyan clinicalapplicationoftwicefluidgasexchangeinvitrectomy AT fenghuachen clinicalapplicationoftwicefluidgasexchangeinvitrectomy AT kaipeng clinicalapplicationoftwicefluidgasexchangeinvitrectomy |
_version_ |
1725000561927913472 |