Influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pump

The article describes the experimental setup for testing a heat pump and the results of its operation at various temperatures at its inlet and outlet. An actually task is to study the operation of a heat pump under various boundary conditions, which are determined from the phase transition temperatu...

Full description

Bibliographic Details
Main Authors: Yuriy A. Antipov, Kirill V. Shkarin, Irina I. Shatalova, Semen A. Egorov, Nargiza U. Matyakubova
Format: Article
Language:English
Published: Peoples’ Friendship University of Russia (RUDN University) 2019-12-01
Series:RUDN Journal of Engineering Researches
Online Access:http://journals.rudn.ru/engineering-researches/article/viewFile/21420/17091
id doaj-7c62a575943b4046a0749e5712308c30
record_format Article
spelling doaj-7c62a575943b4046a0749e5712308c302020-11-25T02:01:47ZengPeoples’ Friendship University of Russia (RUDN University)RUDN Journal of Engineering Researches2312-81432312-81512019-12-01201141910.22363/2312-8143-2019-20-1-14-1917762Influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pumpYuriy A. Antipov0Kirill V. Shkarin1Irina I. Shatalova2Semen A. Egorov3Nargiza U. Matyakubova4Peoples’ Friendship University of Russia (RUDN University)Peoples’ Friendship University of Russia (RUDN University)Peoples’ Friendship University of Russia (RUDN University)Peoples’ Friendship University of Russia (RUDN University)Peoples’ Friendship University of Russia (RUDN University)The article describes the experimental setup for testing a heat pump and the results of its operation at various temperatures at its inlet and outlet. An actually task is to study the operation of a heat pump under various boundary conditions, which are determined from the phase transition temperature in the evaporator and condenser. These temperatures depend on the temperature in the evaporator of a low-potential source of heat (the lower source is water, air, etc.) and the temperature in the condenser of a high-potential source of heat (the upper source is a consumer). The main indicator of the efficiency of the heat pump is the coefficient of performance. To determine the reliable value of the coefficient of performance, tests of compression heat pump were carried out. Refrigerant R-142b was used as a working fluid. Based on the experimental data, the dependences of the coefficient of performance on the temperature of the hot and cold heat source are constructed. Also, the coefficient of performance heat pump decreases when the lower heat source decreases.http://journals.rudn.ru/engineering-researches/article/viewFile/21420/17091
collection DOAJ
language English
format Article
sources DOAJ
author Yuriy A. Antipov
Kirill V. Shkarin
Irina I. Shatalova
Semen A. Egorov
Nargiza U. Matyakubova
spellingShingle Yuriy A. Antipov
Kirill V. Shkarin
Irina I. Shatalova
Semen A. Egorov
Nargiza U. Matyakubova
Influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pump
RUDN Journal of Engineering Researches
author_facet Yuriy A. Antipov
Kirill V. Shkarin
Irina I. Shatalova
Semen A. Egorov
Nargiza U. Matyakubova
author_sort Yuriy A. Antipov
title Influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pump
title_short Influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pump
title_full Influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pump
title_fullStr Influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pump
title_full_unstemmed Influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pump
title_sort influence of temperatures of a low-potential source and heat consumer on the efficiency of a heat pump
publisher Peoples’ Friendship University of Russia (RUDN University)
series RUDN Journal of Engineering Researches
issn 2312-8143
2312-8151
publishDate 2019-12-01
description The article describes the experimental setup for testing a heat pump and the results of its operation at various temperatures at its inlet and outlet. An actually task is to study the operation of a heat pump under various boundary conditions, which are determined from the phase transition temperature in the evaporator and condenser. These temperatures depend on the temperature in the evaporator of a low-potential source of heat (the lower source is water, air, etc.) and the temperature in the condenser of a high-potential source of heat (the upper source is a consumer). The main indicator of the efficiency of the heat pump is the coefficient of performance. To determine the reliable value of the coefficient of performance, tests of compression heat pump were carried out. Refrigerant R-142b was used as a working fluid. Based on the experimental data, the dependences of the coefficient of performance on the temperature of the hot and cold heat source are constructed. Also, the coefficient of performance heat pump decreases when the lower heat source decreases.
url http://journals.rudn.ru/engineering-researches/article/viewFile/21420/17091
work_keys_str_mv AT yuriyaantipov influenceoftemperaturesofalowpotentialsourceandheatconsumerontheefficiencyofaheatpump
AT kirillvshkarin influenceoftemperaturesofalowpotentialsourceandheatconsumerontheefficiencyofaheatpump
AT irinaishatalova influenceoftemperaturesofalowpotentialsourceandheatconsumerontheefficiencyofaheatpump
AT semenaegorov influenceoftemperaturesofalowpotentialsourceandheatconsumerontheefficiencyofaheatpump
AT nargizaumatyakubova influenceoftemperaturesofalowpotentialsourceandheatconsumerontheefficiencyofaheatpump
_version_ 1724955782814892032