Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt
This study aims to realize the manufacturing of a prototype design of a pico-hydro power plant, which is expected to be a science of study and a reference for students at the University of Singaperbangsa Karawang in particular and Indonesian students in general, as well as monitoring the performance...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Udayana
2020-11-01
|
Series: | Jurnal Energi Dan Manufaktur |
Online Access: | https://ojs.unud.ac.id/index.php/jem/article/view/65046 |
id |
doaj-7c0bed2f84ba46878fd2bb744b671da8 |
---|---|
record_format |
Article |
spelling |
doaj-7c0bed2f84ba46878fd2bb744b671da82020-11-25T04:03:09ZengUniversitas UdayanaJurnal Energi Dan Manufaktur2302-52552541-53282020-11-01132636910.24843/JEM.2020.v13.i02.p0465046Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 WattMuhammad Ibrahim0Iman Dirja1Viktor Naubnome2Universitas Singaperbangsa KarawangUniversitas Singaperbangsa KarawangUniversitas Singaperbangsa KarawangThis study aims to realize the manufacturing of a prototype design of a pico-hydro power plant, which is expected to be a science of study and a reference for students at the University of Singaperbangsa Karawang in particular and Indonesian students in general, as well as monitoring the performance test of the prototype of pico-hydro power plant that is used as an electricity needs for lighting. The design and manufacture of this prototype require several supporting components: a). Pressure gauge; b). Pelton type turbines; c). Tacho Meter; d). Single-phase Ac generator; e). Avometer; f). Energy saving LED lamp. Pico-hydro power plant prototype testing is carried out by measuring the voltage generated by the generator, tested at no load and given a load using variations of 55%, 70%, 85%, 100% valve openings. Based on the results of the performance test, the pico-hydro power plant can work well. That matter can be seen from the largest flow valve opening which results in a high water flow rate, so that it can rotate the turbine quickly. The flow rate greatly affects the generator rotation. No-load test results, the largest voltage of 90 volts is obtained when using 100% valve opening, with the output producing an air flow of 0.0017 m3 / s, rotation (N1) 136 rpm, rotation (N2) 979 rpm. The results with the load, the largest voltage of 60 volts is obtained when using 100% valve openings, with the output producing rotation (N1) 133 rpm, rotation (N2) 957 rpm, and current 0.13 A when supplying the 4 LED lamps type of 3 watts with litting up brightly.https://ojs.unud.ac.id/index.php/jem/article/view/65046 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Muhammad Ibrahim Iman Dirja Viktor Naubnome |
spellingShingle |
Muhammad Ibrahim Iman Dirja Viktor Naubnome Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt Jurnal Energi Dan Manufaktur |
author_facet |
Muhammad Ibrahim Iman Dirja Viktor Naubnome |
author_sort |
Muhammad Ibrahim |
title |
Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt |
title_short |
Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt |
title_full |
Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt |
title_fullStr |
Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt |
title_full_unstemmed |
Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt |
title_sort |
rancang bangun prototipe pltph sebagai listrik penerangan kapasitas 9 watt |
publisher |
Universitas Udayana |
series |
Jurnal Energi Dan Manufaktur |
issn |
2302-5255 2541-5328 |
publishDate |
2020-11-01 |
description |
This study aims to realize the manufacturing of a prototype design of a pico-hydro power plant, which is expected to be a science of study and a reference for students at the University of Singaperbangsa Karawang in particular and Indonesian students in general, as well as monitoring the performance test of the prototype of pico-hydro power plant that is used as an electricity needs for lighting. The design and manufacture of this prototype require several supporting components: a). Pressure gauge; b). Pelton type turbines; c). Tacho Meter; d). Single-phase Ac generator; e). Avometer; f). Energy saving LED lamp. Pico-hydro power plant prototype testing is carried out by measuring the voltage generated by the generator, tested at no load and given a load using variations of 55%, 70%, 85%, 100% valve openings. Based on the results of the performance test, the pico-hydro power plant can work well. That matter can be seen from the largest flow valve opening which results in a high water flow rate, so that it can rotate the turbine quickly. The flow rate greatly affects the generator rotation. No-load test results, the largest voltage of 90 volts is obtained when using 100% valve opening, with the output producing an air flow of 0.0017 m3 / s, rotation (N1) 136 rpm, rotation (N2) 979 rpm. The results with the load, the largest voltage of 60 volts is obtained when using 100% valve openings, with the output producing rotation (N1) 133 rpm, rotation (N2) 957 rpm, and current 0.13 A when supplying the 4 LED lamps type of 3 watts with litting up brightly. |