Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt

This study aims to realize the manufacturing of a prototype design of a pico-hydro power plant, which is expected to be a science of study and a reference for students at the University of Singaperbangsa Karawang in particular and Indonesian students in general, as well as monitoring the performance...

Full description

Bibliographic Details
Main Authors: Muhammad Ibrahim, Iman Dirja, Viktor Naubnome
Format: Article
Language:English
Published: Universitas Udayana 2020-11-01
Series:Jurnal Energi Dan Manufaktur
Online Access:https://ojs.unud.ac.id/index.php/jem/article/view/65046
id doaj-7c0bed2f84ba46878fd2bb744b671da8
record_format Article
spelling doaj-7c0bed2f84ba46878fd2bb744b671da82020-11-25T04:03:09ZengUniversitas UdayanaJurnal Energi Dan Manufaktur2302-52552541-53282020-11-01132636910.24843/JEM.2020.v13.i02.p0465046Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 WattMuhammad Ibrahim0Iman Dirja1Viktor Naubnome2Universitas Singaperbangsa KarawangUniversitas Singaperbangsa KarawangUniversitas Singaperbangsa KarawangThis study aims to realize the manufacturing of a prototype design of a pico-hydro power plant, which is expected to be a science of study and a reference for students at the University of Singaperbangsa Karawang in particular and Indonesian students in general, as well as monitoring the performance test of the prototype of pico-hydro power plant that is used as an electricity needs for lighting. The design and manufacture of this prototype require several supporting components: a). Pressure gauge; b). Pelton type turbines; c). Tacho Meter; d). Single-phase Ac generator; e). Avometer; f). Energy saving LED lamp. Pico-hydro power plant prototype testing is carried out by measuring the voltage generated by the generator, tested at no load and given a load using variations of 55%, 70%, 85%, 100% valve openings. Based on the results of the performance test, the pico-hydro power plant can work well. That matter can be seen from the largest flow valve opening which results in a high water flow rate, so that it can rotate the turbine quickly. The flow rate greatly affects the generator rotation. No-load test results, the largest voltage of 90 volts is obtained when using 100% valve opening, with the output producing an air flow of 0.0017 m3 / s, rotation (N1) 136 rpm, rotation (N2) 979 rpm. The results with the load, the largest voltage of 60 volts is obtained when using 100% valve openings, with the output producing rotation (N1) 133 rpm, rotation (N2) 957 rpm, and current 0.13 A when supplying the 4 LED lamps type of 3 watts with litting up brightly.https://ojs.unud.ac.id/index.php/jem/article/view/65046
collection DOAJ
language English
format Article
sources DOAJ
author Muhammad Ibrahim
Iman Dirja
Viktor Naubnome
spellingShingle Muhammad Ibrahim
Iman Dirja
Viktor Naubnome
Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt
Jurnal Energi Dan Manufaktur
author_facet Muhammad Ibrahim
Iman Dirja
Viktor Naubnome
author_sort Muhammad Ibrahim
title Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt
title_short Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt
title_full Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt
title_fullStr Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt
title_full_unstemmed Rancang Bangun Prototipe PLTPh Sebagai Listrik Penerangan Kapasitas 9 Watt
title_sort rancang bangun prototipe pltph sebagai listrik penerangan kapasitas 9 watt
publisher Universitas Udayana
series Jurnal Energi Dan Manufaktur
issn 2302-5255
2541-5328
publishDate 2020-11-01
description This study aims to realize the manufacturing of a prototype design of a pico-hydro power plant, which is expected to be a science of study and a reference for students at the University of Singaperbangsa Karawang in particular and Indonesian students in general, as well as monitoring the performance test of the prototype of pico-hydro power plant that is used as an electricity needs for lighting. The design and manufacture of this prototype require several supporting components: a). Pressure gauge; b). Pelton type turbines; c). Tacho Meter; d). Single-phase Ac generator; e). Avometer; f). Energy saving LED lamp. Pico-hydro power plant prototype testing is carried out by measuring the voltage generated by the generator, tested at no load and given a load using variations of 55%, 70%, 85%, 100% valve openings. Based on the results of the performance test, the pico-hydro power plant can work well. That matter can be seen from the largest flow valve opening which results in a high water flow rate, so that it can rotate the turbine quickly. The flow rate greatly affects the generator rotation. No-load test results, the largest voltage of 90 volts is obtained when using 100% valve opening, with the output producing an air flow of 0.0017 m3 / s, rotation (N1) 136 rpm, rotation (N2) 979 rpm. The results with the load, the largest voltage of 60 volts is obtained when using 100% valve openings, with the output producing rotation (N1) 133 rpm, rotation (N2) 957 rpm, and current 0.13 A when supplying the 4 LED lamps type of 3 watts with litting up brightly.
url https://ojs.unud.ac.id/index.php/jem/article/view/65046
work_keys_str_mv AT muhammadibrahim rancangbangunprototipepltphsebagailistrikpenerangankapasitas9watt
AT imandirja rancangbangunprototipepltphsebagailistrikpenerangankapasitas9watt
AT viktornaubnome rancangbangunprototipepltphsebagailistrikpenerangankapasitas9watt
_version_ 1724441329141809152