Granite stone subjected to ultrasonic fatigue tests under three point bending loading
Ultrasonic fatigue tests are carried out under the modality of three point bending on the granite stone. The testing specimens present a prismatic shape with the dimensions: 12 x 3 x 0.8 centimeters, in order to be supported by its two ends, and to configure the three point bending modality. Granite...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Gruppo Italiano Frattura
2019-04-01
|
Series: | Frattura ed Integrità Strutturale |
Subjects: | |
Online Access: | https://www.fracturae.com/index.php/fis/article/view/2317/2360 |
id |
doaj-7bffc28e20324faa8fd813b5508d9192 |
---|---|
record_format |
Article |
spelling |
doaj-7bffc28e20324faa8fd813b5508d91922020-11-25T00:19:46ZengGruppo Italiano FratturaFrattura ed Integrità Strutturale1971-89932019-04-011348707610.3221/IGF-ESIS.48.0910.3221/IGF-ESIS.48.09Granite stone subjected to ultrasonic fatigue tests under three point bending loadingDominguez AlexianeGonzalo Mariano Dominguez AlmarazNecker J. Trujillo AlonsoUltrasonic fatigue tests are carried out under the modality of three point bending on the granite stone. The testing specimens present a prismatic shape with the dimensions: 12 x 3 x 0.8 centimeters, in order to be supported by its two ends, and to configure the three point bending modality. Granite specimens are supported on an acrylic structure destined to fix and immobilize the specimens. Vibrating load is applied at the center of testing specimens by a self-designed and fabricated aluminum alloy awl, whose dimensions have been obtained by modal numerical analysis to fit the resonance condition, necessary for the ultrasonic fatigue tests. Experimental results are obtained at room temperature and humidity between 65 and 75%. The fatigue endurance is determined on the granite under this modality of loading, and the fracture surfaces are analyzed to identify the principal trends related to crack initiation and propagation on this material.https://www.fracturae.com/index.php/fis/article/view/2317/2360Granite stoneThree point bendingUltrasonic loadingFatigue enduranceFracture surfaces |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dominguez Alexiane Gonzalo Mariano Dominguez Almaraz Necker J. Trujillo Alonso |
spellingShingle |
Dominguez Alexiane Gonzalo Mariano Dominguez Almaraz Necker J. Trujillo Alonso Granite stone subjected to ultrasonic fatigue tests under three point bending loading Frattura ed Integrità Strutturale Granite stone Three point bending Ultrasonic loading Fatigue endurance Fracture surfaces |
author_facet |
Dominguez Alexiane Gonzalo Mariano Dominguez Almaraz Necker J. Trujillo Alonso |
author_sort |
Dominguez Alexiane |
title |
Granite stone subjected to ultrasonic fatigue tests under three point bending loading |
title_short |
Granite stone subjected to ultrasonic fatigue tests under three point bending loading |
title_full |
Granite stone subjected to ultrasonic fatigue tests under three point bending loading |
title_fullStr |
Granite stone subjected to ultrasonic fatigue tests under three point bending loading |
title_full_unstemmed |
Granite stone subjected to ultrasonic fatigue tests under three point bending loading |
title_sort |
granite stone subjected to ultrasonic fatigue tests under three point bending loading |
publisher |
Gruppo Italiano Frattura |
series |
Frattura ed Integrità Strutturale |
issn |
1971-8993 |
publishDate |
2019-04-01 |
description |
Ultrasonic fatigue tests are carried out under the modality of three point bending on the granite stone. The testing specimens present a prismatic shape with the dimensions: 12 x 3 x 0.8 centimeters, in order to be supported by its two ends, and to configure the three point bending modality. Granite specimens are supported on an acrylic structure destined to fix and immobilize the specimens. Vibrating load is applied at the center of testing specimens by a self-designed and fabricated aluminum alloy awl, whose dimensions have been obtained by modal numerical analysis to fit the resonance condition, necessary for the ultrasonic fatigue tests. Experimental results are obtained at room temperature and humidity between 65 and 75%. The fatigue endurance is determined on the granite under this modality of loading, and the fracture surfaces are analyzed to identify the principal trends related to crack initiation and propagation on this material. |
topic |
Granite stone Three point bending Ultrasonic loading Fatigue endurance Fracture surfaces |
url |
https://www.fracturae.com/index.php/fis/article/view/2317/2360 |
work_keys_str_mv |
AT dominguezalexiane granitestonesubjectedtoultrasonicfatiguetestsunderthreepointbendingloading AT gonzalomarianodominguezalmaraz granitestonesubjectedtoultrasonicfatiguetestsunderthreepointbendingloading AT neckerjtrujilloalonso granitestonesubjectedtoultrasonicfatiguetestsunderthreepointbendingloading |
_version_ |
1725370197513076736 |