Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle
[Introduction] In order to improve the operational flexibility of the gas turbine combined cycle unit, ensure better economic performance of the unit, and avoid the gas turbine working in the inefficient operation area, this paper analyzes and studies the inlet air cooling system of the gas turbine....
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Energy Observer Magazine Co., Ltd.
2019-09-01
|
Series: | 南方能源建设 |
Subjects: | |
Online Access: | https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2019.03.011 |
id |
doaj-7be9c622bf154009ae483d66e143fb84 |
---|---|
record_format |
Article |
spelling |
doaj-7be9c622bf154009ae483d66e143fb842021-08-24T03:24:28ZengEnergy Observer Magazine Co., Ltd.南方能源建设2095-86762019-09-0163646910.16516/j.gedi.issn2095-8676.2019.03.011Effect of Inlet Air Cooling on Performance of Gas Turbine Combined CycleLIN Yan0YANG Daohong1China Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd., Guangzhou 510663, ChinaChina Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd., Guangzhou 510663, China[Introduction] In order to improve the operational flexibility of the gas turbine combined cycle unit, ensure better economic performance of the unit, and avoid the gas turbine working in the inefficient operation area, this paper analyzes and studies the inlet air cooling system of the gas turbine. [Method] The performance change and its influencing factors and the efficiency sensitivity analysis of gas turbine combined cycle unit were studied according to the thermal balance simulation results of considering inlet air cooling or not, based on the GT-Pro/GT-Master software platform. [Result] The analysis results show that the output and efficiency of the gas turbine are greatly improved after using the inlet cooling system, and the output of the combined cycle unit is also increased while the efficiency is slightly reduced. [Conclusion] Therefore, for the combined cycle unit, if the unit is supposed to generate more power, the inlet air cooling system should be used; if the total annual output of the unit is fixed and the annual utilization hours are relatively small, the inlet air cooling system should not be used.https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2019.03.011combined cycleinlet air coolinggas turbine outputgas turbine efficiencycombined cycle unit output |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
LIN Yan YANG Daohong |
spellingShingle |
LIN Yan YANG Daohong Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle 南方能源建设 combined cycle inlet air cooling gas turbine output gas turbine efficiency combined cycle unit output |
author_facet |
LIN Yan YANG Daohong |
author_sort |
LIN Yan |
title |
Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle |
title_short |
Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle |
title_full |
Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle |
title_fullStr |
Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle |
title_full_unstemmed |
Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle |
title_sort |
effect of inlet air cooling on performance of gas turbine combined cycle |
publisher |
Energy Observer Magazine Co., Ltd. |
series |
南方能源建设 |
issn |
2095-8676 |
publishDate |
2019-09-01 |
description |
[Introduction] In order to improve the operational flexibility of the gas turbine combined cycle unit, ensure better economic performance of the unit, and avoid the gas turbine working in the inefficient operation area, this paper analyzes and studies the inlet air cooling system of the gas turbine. [Method] The performance change and its influencing factors and the efficiency sensitivity analysis of gas turbine combined cycle unit were studied according to the thermal balance simulation results of considering inlet air cooling or not, based on the GT-Pro/GT-Master software platform. [Result] The analysis results show that the output and efficiency of the gas turbine are greatly improved after using the inlet cooling system, and the output of the combined cycle unit is also increased while the efficiency is slightly reduced. [Conclusion] Therefore, for the combined cycle unit, if the unit is supposed to generate more power, the inlet air cooling system should be used; if the total annual output of the unit is fixed and the annual utilization hours are relatively small, the inlet air cooling system should not be used. |
topic |
combined cycle inlet air cooling gas turbine output gas turbine efficiency combined cycle unit output |
url |
https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2019.03.011 |
work_keys_str_mv |
AT linyan effectofinletaircoolingonperformanceofgasturbinecombinedcycle AT yangdaohong effectofinletaircoolingonperformanceofgasturbinecombinedcycle |
_version_ |
1721198056815198208 |