Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle

[Introduction] In order to improve the operational flexibility of the gas turbine combined cycle unit, ensure better economic performance of the unit, and avoid the gas turbine working in the inefficient operation area, this paper analyzes and studies the inlet air cooling system of the gas turbine....

Full description

Bibliographic Details
Main Authors: LIN Yan, YANG Daohong
Format: Article
Language:English
Published: Energy Observer Magazine Co., Ltd. 2019-09-01
Series:南方能源建设
Subjects:
Online Access:https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2019.03.011
id doaj-7be9c622bf154009ae483d66e143fb84
record_format Article
spelling doaj-7be9c622bf154009ae483d66e143fb842021-08-24T03:24:28ZengEnergy Observer Magazine Co., Ltd.南方能源建设2095-86762019-09-0163646910.16516/j.gedi.issn2095-8676.2019.03.011Effect of Inlet Air Cooling on Performance of Gas Turbine Combined CycleLIN Yan0YANG Daohong1China Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd., Guangzhou 510663, ChinaChina Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd., Guangzhou 510663, China[Introduction] In order to improve the operational flexibility of the gas turbine combined cycle unit, ensure better economic performance of the unit, and avoid the gas turbine working in the inefficient operation area, this paper analyzes and studies the inlet air cooling system of the gas turbine. [Method] The performance change and its influencing factors and the efficiency sensitivity analysis of gas turbine combined cycle unit were studied according to the thermal balance simulation results of considering inlet air cooling or not, based on the GT-Pro/GT-Master software platform. [Result] The analysis results show that the output and efficiency of the gas turbine are greatly improved after using the inlet cooling system, and the output of the combined cycle unit is also increased while the efficiency is slightly reduced. [Conclusion] Therefore, for the combined cycle unit, if the unit is supposed to generate more power, the inlet air cooling system should be used; if the total annual output of the unit is fixed and the annual utilization hours are relatively small, the inlet air cooling system should not be used.https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2019.03.011combined cycleinlet air coolinggas turbine outputgas turbine efficiencycombined cycle unit output
collection DOAJ
language English
format Article
sources DOAJ
author LIN Yan
YANG Daohong
spellingShingle LIN Yan
YANG Daohong
Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle
南方能源建设
combined cycle
inlet air cooling
gas turbine output
gas turbine efficiency
combined cycle unit output
author_facet LIN Yan
YANG Daohong
author_sort LIN Yan
title Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle
title_short Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle
title_full Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle
title_fullStr Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle
title_full_unstemmed Effect of Inlet Air Cooling on Performance of Gas Turbine Combined Cycle
title_sort effect of inlet air cooling on performance of gas turbine combined cycle
publisher Energy Observer Magazine Co., Ltd.
series 南方能源建设
issn 2095-8676
publishDate 2019-09-01
description [Introduction] In order to improve the operational flexibility of the gas turbine combined cycle unit, ensure better economic performance of the unit, and avoid the gas turbine working in the inefficient operation area, this paper analyzes and studies the inlet air cooling system of the gas turbine. [Method] The performance change and its influencing factors and the efficiency sensitivity analysis of gas turbine combined cycle unit were studied according to the thermal balance simulation results of considering inlet air cooling or not, based on the GT-Pro/GT-Master software platform. [Result] The analysis results show that the output and efficiency of the gas turbine are greatly improved after using the inlet cooling system, and the output of the combined cycle unit is also increased while the efficiency is slightly reduced. [Conclusion] Therefore, for the combined cycle unit, if the unit is supposed to generate more power, the inlet air cooling system should be used; if the total annual output of the unit is fixed and the annual utilization hours are relatively small, the inlet air cooling system should not be used.
topic combined cycle
inlet air cooling
gas turbine output
gas turbine efficiency
combined cycle unit output
url https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2019.03.011
work_keys_str_mv AT linyan effectofinletaircoolingonperformanceofgasturbinecombinedcycle
AT yangdaohong effectofinletaircoolingonperformanceofgasturbinecombinedcycle
_version_ 1721198056815198208