Particle number size distributions in urban air before and after volatilisation

Aerosol particle number size distributions (size range 0.003–10 μm) in the urban atmosphere of Augsburg (Germany) were examined with respect to the governing anthropogenic sources and meteorological factors. The two-year average particle number concentration between November 2004 and Nove...

Full description

Bibliographic Details
Main Authors: W. Birmili, K. Heinke, M. Pitz, J. Matschullat, A. Wiedensohler, J. Cyrys, H.-E. Wichmann, A. Peters
Format: Article
Language:English
Published: Copernicus Publications 2010-05-01
Series:Atmospheric Chemistry and Physics
Online Access:http://www.atmos-chem-phys.net/10/4643/2010/acp-10-4643-2010.pdf
id doaj-7b8c20b90d494ebbab01271eda783645
record_format Article
spelling doaj-7b8c20b90d494ebbab01271eda7836452020-11-25T00:50:07ZengCopernicus PublicationsAtmospheric Chemistry and Physics1680-73161680-73242010-05-0110104643466010.5194/acp-10-4643-2010Particle number size distributions in urban air before and after volatilisationW. BirmiliK. HeinkeM. PitzJ. MatschullatA. WiedensohlerJ. CyrysH.-E. WichmannA. PetersAerosol particle number size distributions (size range 0.003–10 μm) in the urban atmosphere of Augsburg (Germany) were examined with respect to the governing anthropogenic sources and meteorological factors. The two-year average particle number concentration between November 2004 and November 2006 was 12 200 cm<sup>−3</sup>, i.e. similar to previous observations in other European cities. A seasonal analysis yielded twice the total particle number concentrations in winter as compared to summer as consequence of more frequent inversion situations and enhanced particulate emissions. The diurnal variations of particle number were shaped by a remarkable maximum in the morning during the peak traffic hours. After a mid-day decrease along with the onset of vertical mixing, an evening concentration maximum could frequently be observed, suggesting a re-stratification of the urban atmosphere. Overall, the mixed layer height turned out to be the most influential meteorological parameter on the particle size distribution. Its influence was even greater than that of the geographical origin of the prevailing synoptic-scale air mass. <br><br> Size distributions below 0.8 μm were also measured downstream of a thermodenuder (temperature: 300 °C), allowing to retrieve the volume concentration of non-volatile compounds. The balance of particle number upstream and downstream of the thermodenuder suggests that practically all particles >12 nm contain a non-volatile core while additional nucleation of particles smaller than 6 nm could be observed after the thermodenuder as an interfering artifact of the method. The good correlation between the non-volatile volume concentration and an independent measurement of the aerosol absorption coefficient (<i>R</i><sup>2</sup>=0.9) suggests a close correspondence of the refractory and light-absorbing particle fractions. Using the "summation method", an average diameter ratio of particles before and after volatilisation could be determined as a function of particle size. The results indicated that particles >60 nm contain a significantly higher fraction of non-volatile compounds, most likely black carbon, than particles <60 nm. The results are relevant for future health-related studies in that they explore the size distribution and time-dependent behaviour of the refractory component of the urban aerosol over an extended time period. http://www.atmos-chem-phys.net/10/4643/2010/acp-10-4643-2010.pdf
collection DOAJ
language English
format Article
sources DOAJ
author W. Birmili
K. Heinke
M. Pitz
J. Matschullat
A. Wiedensohler
J. Cyrys
H.-E. Wichmann
A. Peters
spellingShingle W. Birmili
K. Heinke
M. Pitz
J. Matschullat
A. Wiedensohler
J. Cyrys
H.-E. Wichmann
A. Peters
Particle number size distributions in urban air before and after volatilisation
Atmospheric Chemistry and Physics
author_facet W. Birmili
K. Heinke
M. Pitz
J. Matschullat
A. Wiedensohler
J. Cyrys
H.-E. Wichmann
A. Peters
author_sort W. Birmili
title Particle number size distributions in urban air before and after volatilisation
title_short Particle number size distributions in urban air before and after volatilisation
title_full Particle number size distributions in urban air before and after volatilisation
title_fullStr Particle number size distributions in urban air before and after volatilisation
title_full_unstemmed Particle number size distributions in urban air before and after volatilisation
title_sort particle number size distributions in urban air before and after volatilisation
publisher Copernicus Publications
series Atmospheric Chemistry and Physics
issn 1680-7316
1680-7324
publishDate 2010-05-01
description Aerosol particle number size distributions (size range 0.003–10 μm) in the urban atmosphere of Augsburg (Germany) were examined with respect to the governing anthropogenic sources and meteorological factors. The two-year average particle number concentration between November 2004 and November 2006 was 12 200 cm<sup>−3</sup>, i.e. similar to previous observations in other European cities. A seasonal analysis yielded twice the total particle number concentrations in winter as compared to summer as consequence of more frequent inversion situations and enhanced particulate emissions. The diurnal variations of particle number were shaped by a remarkable maximum in the morning during the peak traffic hours. After a mid-day decrease along with the onset of vertical mixing, an evening concentration maximum could frequently be observed, suggesting a re-stratification of the urban atmosphere. Overall, the mixed layer height turned out to be the most influential meteorological parameter on the particle size distribution. Its influence was even greater than that of the geographical origin of the prevailing synoptic-scale air mass. <br><br> Size distributions below 0.8 μm were also measured downstream of a thermodenuder (temperature: 300 °C), allowing to retrieve the volume concentration of non-volatile compounds. The balance of particle number upstream and downstream of the thermodenuder suggests that practically all particles >12 nm contain a non-volatile core while additional nucleation of particles smaller than 6 nm could be observed after the thermodenuder as an interfering artifact of the method. The good correlation between the non-volatile volume concentration and an independent measurement of the aerosol absorption coefficient (<i>R</i><sup>2</sup>=0.9) suggests a close correspondence of the refractory and light-absorbing particle fractions. Using the "summation method", an average diameter ratio of particles before and after volatilisation could be determined as a function of particle size. The results indicated that particles >60 nm contain a significantly higher fraction of non-volatile compounds, most likely black carbon, than particles <60 nm. The results are relevant for future health-related studies in that they explore the size distribution and time-dependent behaviour of the refractory component of the urban aerosol over an extended time period.
url http://www.atmos-chem-phys.net/10/4643/2010/acp-10-4643-2010.pdf
work_keys_str_mv AT wbirmili particlenumbersizedistributionsinurbanairbeforeandaftervolatilisation
AT kheinke particlenumbersizedistributionsinurbanairbeforeandaftervolatilisation
AT mpitz particlenumbersizedistributionsinurbanairbeforeandaftervolatilisation
AT jmatschullat particlenumbersizedistributionsinurbanairbeforeandaftervolatilisation
AT awiedensohler particlenumbersizedistributionsinurbanairbeforeandaftervolatilisation
AT jcyrys particlenumbersizedistributionsinurbanairbeforeandaftervolatilisation
AT hewichmann particlenumbersizedistributionsinurbanairbeforeandaftervolatilisation
AT apeters particlenumbersizedistributionsinurbanairbeforeandaftervolatilisation
_version_ 1725249213445439488