Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description
Abstract Total body irradiation (TBI) is a complex treatment technique, which has been slow to transition to a three‐dimensional (3D) planning approach. There is limited literature available providing a detailed description on methods to plan TBI on a 3D planning system. 3D planning using the modula...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2019-12-01
|
Series: | Journal of Medical Radiation Sciences |
Subjects: | |
Online Access: | https://doi.org/10.1002/jmrs.363 |
id |
doaj-7b630b9466634ba5a6bd33d3007d0193 |
---|---|
record_format |
Article |
spelling |
doaj-7b630b9466634ba5a6bd33d3007d01932020-11-25T03:55:13ZengWileyJournal of Medical Radiation Sciences2051-38952051-39092019-12-0166428429110.1002/jmrs.363Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry descriptionBeth Effeney0Jennifer Biggs1Carole Brady2Melanie Pemberton3Lucy Sim4Andrew Pullar5Radiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaAbstract Total body irradiation (TBI) is a complex treatment technique, which has been slow to transition to a three‐dimensional (3D) planning approach. There is limited literature available providing a detailed description on methods to plan TBI on a 3D planning system. 3D planning using the modulated arc TBI (MATBI) technique is a complex process involving a significant number of quality assurance processes and scripts, due to more than 40 treatment beams and two patient positions. This article will focus on the workflow and technical planning aspects of our institution’s MATBI technique and identify reasons for modifications made to the developing institution’s original MATBI approach. Included is a description of specific simulation equipment, detailed explanation of the four‐stage computing process including the role of scripting to standardise and streamline what is otherwise a complex number of steps. The information provided is specific to one centre’s approach but shows the fundamental planning process and demonstrates a streamlined method, which can be adapted to other planning systems. Overall, the ability to accurately represent the TBI technique in 3D on a planning system will be shown.https://doi.org/10.1002/jmrs.363total body irradiationmodulated arc therapypaediatric cancers |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Beth Effeney Jennifer Biggs Carole Brady Melanie Pemberton Lucy Sim Andrew Pullar |
spellingShingle |
Beth Effeney Jennifer Biggs Carole Brady Melanie Pemberton Lucy Sim Andrew Pullar Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description Journal of Medical Radiation Sciences total body irradiation modulated arc therapy paediatric cancers |
author_facet |
Beth Effeney Jennifer Biggs Carole Brady Melanie Pemberton Lucy Sim Andrew Pullar |
author_sort |
Beth Effeney |
title |
Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description |
title_short |
Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description |
title_full |
Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description |
title_fullStr |
Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description |
title_full_unstemmed |
Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description |
title_sort |
considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description |
publisher |
Wiley |
series |
Journal of Medical Radiation Sciences |
issn |
2051-3895 2051-3909 |
publishDate |
2019-12-01 |
description |
Abstract Total body irradiation (TBI) is a complex treatment technique, which has been slow to transition to a three‐dimensional (3D) planning approach. There is limited literature available providing a detailed description on methods to plan TBI on a 3D planning system. 3D planning using the modulated arc TBI (MATBI) technique is a complex process involving a significant number of quality assurance processes and scripts, due to more than 40 treatment beams and two patient positions. This article will focus on the workflow and technical planning aspects of our institution’s MATBI technique and identify reasons for modifications made to the developing institution’s original MATBI approach. Included is a description of specific simulation equipment, detailed explanation of the four‐stage computing process including the role of scripting to standardise and streamline what is otherwise a complex number of steps. The information provided is specific to one centre’s approach but shows the fundamental planning process and demonstrates a streamlined method, which can be adapted to other planning systems. Overall, the ability to accurately represent the TBI technique in 3D on a planning system will be shown. |
topic |
total body irradiation modulated arc therapy paediatric cancers |
url |
https://doi.org/10.1002/jmrs.363 |
work_keys_str_mv |
AT betheffeney considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription AT jenniferbiggs considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription AT carolebrady considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription AT melaniepemberton considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription AT lucysim considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription AT andrewpullar considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription |
_version_ |
1724469919062425600 |