Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description

Abstract Total body irradiation (TBI) is a complex treatment technique, which has been slow to transition to a three‐dimensional (3D) planning approach. There is limited literature available providing a detailed description on methods to plan TBI on a 3D planning system. 3D planning using the modula...

Full description

Bibliographic Details
Main Authors: Beth Effeney, Jennifer Biggs, Carole Brady, Melanie Pemberton, Lucy Sim, Andrew Pullar
Format: Article
Language:English
Published: Wiley 2019-12-01
Series:Journal of Medical Radiation Sciences
Subjects:
Online Access:https://doi.org/10.1002/jmrs.363
id doaj-7b630b9466634ba5a6bd33d3007d0193
record_format Article
spelling doaj-7b630b9466634ba5a6bd33d3007d01932020-11-25T03:55:13ZengWileyJournal of Medical Radiation Sciences2051-38952051-39092019-12-0166428429110.1002/jmrs.363Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry descriptionBeth Effeney0Jennifer Biggs1Carole Brady2Melanie Pemberton3Lucy Sim4Andrew Pullar5Radiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaRadiation Oncology Princess Alexandra Hospital – Raymond Terrace Metro South Health Service District South BrisbaneQueensland AustraliaAbstract Total body irradiation (TBI) is a complex treatment technique, which has been slow to transition to a three‐dimensional (3D) planning approach. There is limited literature available providing a detailed description on methods to plan TBI on a 3D planning system. 3D planning using the modulated arc TBI (MATBI) technique is a complex process involving a significant number of quality assurance processes and scripts, due to more than 40 treatment beams and two patient positions. This article will focus on the workflow and technical planning aspects of our institution’s MATBI technique and identify reasons for modifications made to the developing institution’s original MATBI approach. Included is a description of specific simulation equipment, detailed explanation of the four‐stage computing process including the role of scripting to standardise and streamline what is otherwise a complex number of steps. The information provided is specific to one centre’s approach but shows the fundamental planning process and demonstrates a streamlined method, which can be adapted to other planning systems. Overall, the ability to accurately represent the TBI technique in 3D on a planning system will be shown.https://doi.org/10.1002/jmrs.363total body irradiationmodulated arc therapypaediatric cancers
collection DOAJ
language English
format Article
sources DOAJ
author Beth Effeney
Jennifer Biggs
Carole Brady
Melanie Pemberton
Lucy Sim
Andrew Pullar
spellingShingle Beth Effeney
Jennifer Biggs
Carole Brady
Melanie Pemberton
Lucy Sim
Andrew Pullar
Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description
Journal of Medical Radiation Sciences
total body irradiation
modulated arc therapy
paediatric cancers
author_facet Beth Effeney
Jennifer Biggs
Carole Brady
Melanie Pemberton
Lucy Sim
Andrew Pullar
author_sort Beth Effeney
title Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description
title_short Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description
title_full Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description
title_fullStr Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description
title_full_unstemmed Considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description
title_sort considerations and adaptions to the modulated arc total body irradiation technique: dosimetry description
publisher Wiley
series Journal of Medical Radiation Sciences
issn 2051-3895
2051-3909
publishDate 2019-12-01
description Abstract Total body irradiation (TBI) is a complex treatment technique, which has been slow to transition to a three‐dimensional (3D) planning approach. There is limited literature available providing a detailed description on methods to plan TBI on a 3D planning system. 3D planning using the modulated arc TBI (MATBI) technique is a complex process involving a significant number of quality assurance processes and scripts, due to more than 40 treatment beams and two patient positions. This article will focus on the workflow and technical planning aspects of our institution’s MATBI technique and identify reasons for modifications made to the developing institution’s original MATBI approach. Included is a description of specific simulation equipment, detailed explanation of the four‐stage computing process including the role of scripting to standardise and streamline what is otherwise a complex number of steps. The information provided is specific to one centre’s approach but shows the fundamental planning process and demonstrates a streamlined method, which can be adapted to other planning systems. Overall, the ability to accurately represent the TBI technique in 3D on a planning system will be shown.
topic total body irradiation
modulated arc therapy
paediatric cancers
url https://doi.org/10.1002/jmrs.363
work_keys_str_mv AT betheffeney considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription
AT jenniferbiggs considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription
AT carolebrady considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription
AT melaniepemberton considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription
AT lucysim considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription
AT andrewpullar considerationsandadaptionstothemodulatedarctotalbodyirradiationtechniquedosimetrydescription
_version_ 1724469919062425600