Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo method

Calculations of gamma-ray mass attenuation coefficients of various detector materials (crystals) were carried out by means of FLUKA Monte Carlo (MC) method at different gamma-ray energies. NaI, PVT, GSO, GaAs and CdWO4 detector materials were chosen in the calculations. Calculated coefficients were...

Full description

Bibliographic Details
Main Authors: Ermis Elif Ebru, Celiktas Cuneyt
Format: Article
Language:English
Published: EDP Sciences 2015-01-01
Series:EPJ Web of Conferences
Online Access:http://dx.doi.org/10.1051/epjconf/201510002003
id doaj-7b4865fdb23d440eb2381defdd1881ef
record_format Article
spelling doaj-7b4865fdb23d440eb2381defdd1881ef2021-08-02T06:49:37ZengEDP SciencesEPJ Web of Conferences2100-014X2015-01-011000200310.1051/epjconf/201510002003epjconf_tesnat2015_02003Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo methodErmis Elif EbruCeliktas CuneytCalculations of gamma-ray mass attenuation coefficients of various detector materials (crystals) were carried out by means of FLUKA Monte Carlo (MC) method at different gamma-ray energies. NaI, PVT, GSO, GaAs and CdWO4 detector materials were chosen in the calculations. Calculated coefficients were also compared with the National Institute of Standards and Technology (NIST) values. Obtained results through this method were highly in accordance with those of the NIST values. It was concluded from the study that FLUKA MC method can be an alternative way to calculate the gamma-ray mass attenuation coefficients of the detector materials.http://dx.doi.org/10.1051/epjconf/201510002003
collection DOAJ
language English
format Article
sources DOAJ
author Ermis Elif Ebru
Celiktas Cuneyt
spellingShingle Ermis Elif Ebru
Celiktas Cuneyt
Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo method
EPJ Web of Conferences
author_facet Ermis Elif Ebru
Celiktas Cuneyt
author_sort Ermis Elif Ebru
title Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo method
title_short Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo method
title_full Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo method
title_fullStr Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo method
title_full_unstemmed Mass attenuation coefficient calculations of different detector crystals by means of FLUKA Monte Carlo method
title_sort mass attenuation coefficient calculations of different detector crystals by means of fluka monte carlo method
publisher EDP Sciences
series EPJ Web of Conferences
issn 2100-014X
publishDate 2015-01-01
description Calculations of gamma-ray mass attenuation coefficients of various detector materials (crystals) were carried out by means of FLUKA Monte Carlo (MC) method at different gamma-ray energies. NaI, PVT, GSO, GaAs and CdWO4 detector materials were chosen in the calculations. Calculated coefficients were also compared with the National Institute of Standards and Technology (NIST) values. Obtained results through this method were highly in accordance with those of the NIST values. It was concluded from the study that FLUKA MC method can be an alternative way to calculate the gamma-ray mass attenuation coefficients of the detector materials.
url http://dx.doi.org/10.1051/epjconf/201510002003
work_keys_str_mv AT ermiselifebru massattenuationcoefficientcalculationsofdifferentdetectorcrystalsbymeansofflukamontecarlomethod
AT celiktascuneyt massattenuationcoefficientcalculationsofdifferentdetectorcrystalsbymeansofflukamontecarlomethod
_version_ 1721239877902663680