Organic matter removal from mother liquor of gas field wastewater by electro-Fenton process with the addition of H2O2: effect of initial pH
The electro-Fenton (EF) process was applied to treat mother liquor of gas field wastewater (ML-GFW). The Fe-Fe electrodes were used and H2O2 was added to the EF system. Effect of initial pH on chemical oxygen demand (COD) removal efficiency, specific electrical energy consumption (SEEC), specific el...