An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions

In recent years, the increasing penetration level of wind energy into power systems has brought new issues and challenges. One of the main concerns is the issue of dynamic response capability during outer disturbance conditions, especially the fault-tolerance capability during asymmetrical faults. I...

Full description

Bibliographic Details
Main Authors: Dan Wang, Chongru Liu, Gengyin Li
Format: Article
Language:English
Published: MDPI AG 2016-04-01
Series:Energies
Subjects:
Online Access:http://www.mdpi.com/1996-1073/9/4/307
id doaj-7abf398a03be43cb8703860df800e397
record_format Article
spelling doaj-7abf398a03be43cb8703860df800e3972020-11-24T21:04:02ZengMDPI AGEnergies1996-10732016-04-019430710.3390/en9040307en9040307An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault ConditionsDan Wang0Chongru Liu1Gengyin Li2State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Changping District, Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Changping District, Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Changping District, Beijing 102206, ChinaIn recent years, the increasing penetration level of wind energy into power systems has brought new issues and challenges. One of the main concerns is the issue of dynamic response capability during outer disturbance conditions, especially the fault-tolerance capability during asymmetrical faults. In order to improve the fault-tolerance and dynamic response capability under asymmetrical grid fault conditions, an optimal integrated control scheme for the grid-side voltage-source converter (VSC) of direct-driven permanent magnet synchronous generator (PMSG)-based wind turbine systems is proposed in this paper. The optimal control strategy includes a main controller and an additional controller. In the main controller, a double-loop controller based on differential flatness-based theory is designed for grid-side VSC. Two parts are involved in the design process of the flatness-based controller: the reference trajectories generation of flatness output and the implementation of the controller. In the additional control aspect, an auxiliary second harmonic compensation control loop based on an improved calculation method for grid-side instantaneous transmission power is designed by the quasi proportional resonant (Quasi-PR) control principle, which is able to simultaneously restrain the second harmonic components in active power and reactive power injected into the grid without the respective calculation for current control references. Moreover, to reduce the DC-link overvoltage during grid faults, the mathematical model of DC-link voltage is analyzed and a feedforward modified control factor is added to the traditional DC voltage control loop in grid-side VSC. The effectiveness of the optimal control scheme is verified in PSCAD/EMTDC simulation software.http://www.mdpi.com/1996-1073/9/4/307direct-driven permanent magnet synchronous generator (PMSG)-based wind turbinefault-tolerant and dynamic response capabilitydifferential flatness-based controlsecond harmonic compensation controlfeedforward control
collection DOAJ
language English
format Article
sources DOAJ
author Dan Wang
Chongru Liu
Gengyin Li
spellingShingle Dan Wang
Chongru Liu
Gengyin Li
An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions
Energies
direct-driven permanent magnet synchronous generator (PMSG)-based wind turbine
fault-tolerant and dynamic response capability
differential flatness-based control
second harmonic compensation control
feedforward control
author_facet Dan Wang
Chongru Liu
Gengyin Li
author_sort Dan Wang
title An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions
title_short An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions
title_full An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions
title_fullStr An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions
title_full_unstemmed An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions
title_sort optimal integrated control scheme for permanent magnet synchronous generator-based wind turbines under asymmetrical grid fault conditions
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2016-04-01
description In recent years, the increasing penetration level of wind energy into power systems has brought new issues and challenges. One of the main concerns is the issue of dynamic response capability during outer disturbance conditions, especially the fault-tolerance capability during asymmetrical faults. In order to improve the fault-tolerance and dynamic response capability under asymmetrical grid fault conditions, an optimal integrated control scheme for the grid-side voltage-source converter (VSC) of direct-driven permanent magnet synchronous generator (PMSG)-based wind turbine systems is proposed in this paper. The optimal control strategy includes a main controller and an additional controller. In the main controller, a double-loop controller based on differential flatness-based theory is designed for grid-side VSC. Two parts are involved in the design process of the flatness-based controller: the reference trajectories generation of flatness output and the implementation of the controller. In the additional control aspect, an auxiliary second harmonic compensation control loop based on an improved calculation method for grid-side instantaneous transmission power is designed by the quasi proportional resonant (Quasi-PR) control principle, which is able to simultaneously restrain the second harmonic components in active power and reactive power injected into the grid without the respective calculation for current control references. Moreover, to reduce the DC-link overvoltage during grid faults, the mathematical model of DC-link voltage is analyzed and a feedforward modified control factor is added to the traditional DC voltage control loop in grid-side VSC. The effectiveness of the optimal control scheme is verified in PSCAD/EMTDC simulation software.
topic direct-driven permanent magnet synchronous generator (PMSG)-based wind turbine
fault-tolerant and dynamic response capability
differential flatness-based control
second harmonic compensation control
feedforward control
url http://www.mdpi.com/1996-1073/9/4/307
work_keys_str_mv AT danwang anoptimalintegratedcontrolschemeforpermanentmagnetsynchronousgeneratorbasedwindturbinesunderasymmetricalgridfaultconditions
AT chongruliu anoptimalintegratedcontrolschemeforpermanentmagnetsynchronousgeneratorbasedwindturbinesunderasymmetricalgridfaultconditions
AT gengyinli anoptimalintegratedcontrolschemeforpermanentmagnetsynchronousgeneratorbasedwindturbinesunderasymmetricalgridfaultconditions
AT danwang optimalintegratedcontrolschemeforpermanentmagnetsynchronousgeneratorbasedwindturbinesunderasymmetricalgridfaultconditions
AT chongruliu optimalintegratedcontrolschemeforpermanentmagnetsynchronousgeneratorbasedwindturbinesunderasymmetricalgridfaultconditions
AT gengyinli optimalintegratedcontrolschemeforpermanentmagnetsynchronousgeneratorbasedwindturbinesunderasymmetricalgridfaultconditions
_version_ 1716772314407763968