A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients

Background and purpose — Survivorship of total hip arthroplasty (THA) with the ultra-high molecular weight polyethylene (UHMWPE) monoblock cup has been limited due to periprosthetic osteolysis and aseptic loosening, secondary to wear of the UHMWPE. In response, a vitamin E blended highly cross-linke...

Full description

Bibliographic Details
Main Authors: Julie R A Massier, Joost H J Van Erp, Thom E Snijders, Arthur DE Gast
Format: Article
Language:English
Published: Taylor & Francis Group 2020-12-01
Series:Acta Orthopaedica
Online Access:http://dx.doi.org/10.1080/17453674.2020.1807220
id doaj-7a7c65e606a6476d834982cb6f082ea5
record_format Article
spelling doaj-7a7c65e606a6476d834982cb6f082ea52021-01-15T13:32:56ZengTaylor & Francis GroupActa Orthopaedica1745-36741745-36822020-12-0191670571010.1080/17453674.2020.18072201807220A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patientsJulie R A Massier0Joost H J Van Erp1Thom E Snijders2Arthur DE Gast3Clinical Orthopedic Research Center – mNClinical Orthopedic Research Center – mNClinical Orthopedic Research Center – mNClinical Orthopedic Research Center – mNBackground and purpose — Survivorship of total hip arthroplasty (THA) with the ultra-high molecular weight polyethylene (UHMWPE) monoblock cup has been limited due to periprosthetic osteolysis and aseptic loosening, secondary to wear of the UHMWPE. In response, a vitamin E blended highly cross-linked polyethylene (HXLPE) cup was developed. This study set out to compare the wear and clinical 6-year outcomes of vitamin E blended HXLPE with UHMWPE in an isoelastic monoblock cup in patients with hip osteoarthritis who underwent uncemented THA. The 2-year results have been reported previously. Patients and methods — For this randomized controlled trial 199 patients were included. 102 patients received the vitamin E blended HXLPE uncemented acetabular cup and 97 patients the uncemented UHMWPE monoblock cup. Clinical and radiographic parameters were obtained preoperatively, directly postoperatively, and at 3, 12, 24, and 72 months. Wear rates were compared using the femoral head penetration (FHP) rate. Results — 173 patients (87%) completed the 6-year follow-up. The mean NRS scores for rest pain, load pain, and patient satisfaction were 0.3 (SD 1), 0.6 (SD 1), and 8.6 (SD 1) respectively. The mean Harris Hip Score was 93 (SD 12). The FHP rate was lower in the vitamin E blended HXLPE cup (0.028 mm/year) compared with the UHMWPE cup (0.035 mm/year) (p = 0.002). No adverse reactions associated with the clinical application of vitamin E blended HXLPE were observed. 15 complications occurred, equally distributed between the two cups. The 6-year survival to revision rate was 98% for both cups. There was no aseptic loosening. Interpretation — This study shows the superior performance of the HXLPE blended with vitamin E acetabular cup with clinical and radiographic results similar to the UHMWPE acetabular cup.http://dx.doi.org/10.1080/17453674.2020.1807220
collection DOAJ
language English
format Article
sources DOAJ
author Julie R A Massier
Joost H J Van Erp
Thom E Snijders
Arthur DE Gast
spellingShingle Julie R A Massier
Joost H J Van Erp
Thom E Snijders
Arthur DE Gast
A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients
Acta Orthopaedica
author_facet Julie R A Massier
Joost H J Van Erp
Thom E Snijders
Arthur DE Gast
author_sort Julie R A Massier
title A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients
title_short A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients
title_full A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients
title_fullStr A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients
title_full_unstemmed A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients
title_sort vitamin e blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients
publisher Taylor & Francis Group
series Acta Orthopaedica
issn 1745-3674
1745-3682
publishDate 2020-12-01
description Background and purpose — Survivorship of total hip arthroplasty (THA) with the ultra-high molecular weight polyethylene (UHMWPE) monoblock cup has been limited due to periprosthetic osteolysis and aseptic loosening, secondary to wear of the UHMWPE. In response, a vitamin E blended highly cross-linked polyethylene (HXLPE) cup was developed. This study set out to compare the wear and clinical 6-year outcomes of vitamin E blended HXLPE with UHMWPE in an isoelastic monoblock cup in patients with hip osteoarthritis who underwent uncemented THA. The 2-year results have been reported previously. Patients and methods — For this randomized controlled trial 199 patients were included. 102 patients received the vitamin E blended HXLPE uncemented acetabular cup and 97 patients the uncemented UHMWPE monoblock cup. Clinical and radiographic parameters were obtained preoperatively, directly postoperatively, and at 3, 12, 24, and 72 months. Wear rates were compared using the femoral head penetration (FHP) rate. Results — 173 patients (87%) completed the 6-year follow-up. The mean NRS scores for rest pain, load pain, and patient satisfaction were 0.3 (SD 1), 0.6 (SD 1), and 8.6 (SD 1) respectively. The mean Harris Hip Score was 93 (SD 12). The FHP rate was lower in the vitamin E blended HXLPE cup (0.028 mm/year) compared with the UHMWPE cup (0.035 mm/year) (p = 0.002). No adverse reactions associated with the clinical application of vitamin E blended HXLPE were observed. 15 complications occurred, equally distributed between the two cups. The 6-year survival to revision rate was 98% for both cups. There was no aseptic loosening. Interpretation — This study shows the superior performance of the HXLPE blended with vitamin E acetabular cup with clinical and radiographic results similar to the UHMWPE acetabular cup.
url http://dx.doi.org/10.1080/17453674.2020.1807220
work_keys_str_mv AT julieramassier avitamineblendedhighlycrosslinkedpolyethyleneacetabularcupresultsinlesswear6yearresultsofarandomizedcontrolledtrialin199patients
AT joosthjvanerp avitamineblendedhighlycrosslinkedpolyethyleneacetabularcupresultsinlesswear6yearresultsofarandomizedcontrolledtrialin199patients
AT thomesnijders avitamineblendedhighlycrosslinkedpolyethyleneacetabularcupresultsinlesswear6yearresultsofarandomizedcontrolledtrialin199patients
AT arthurdegast avitamineblendedhighlycrosslinkedpolyethyleneacetabularcupresultsinlesswear6yearresultsofarandomizedcontrolledtrialin199patients
AT julieramassier vitamineblendedhighlycrosslinkedpolyethyleneacetabularcupresultsinlesswear6yearresultsofarandomizedcontrolledtrialin199patients
AT joosthjvanerp vitamineblendedhighlycrosslinkedpolyethyleneacetabularcupresultsinlesswear6yearresultsofarandomizedcontrolledtrialin199patients
AT thomesnijders vitamineblendedhighlycrosslinkedpolyethyleneacetabularcupresultsinlesswear6yearresultsofarandomizedcontrolledtrialin199patients
AT arthurdegast vitamineblendedhighlycrosslinkedpolyethyleneacetabularcupresultsinlesswear6yearresultsofarandomizedcontrolledtrialin199patients
_version_ 1724336843015585792