Impact of intravitreous injection of additional volume of liquid on intraocular pressure
This work is about investigation of condition of intraocular pressure (IOP) after intravitreous injection of medicine avastine into eyeball with normal hydrodynamic. Injections were made for treatment of neovascular chorioretinal membrane plainly. The medicine was injected intravitreously in volume...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Peoples’ Friendship University of Russia (RUDN University)
2010-09-01
|
Series: | RUDN Journal of Medicine |
Subjects: | |
Online Access: | http://journals.rudn.ru/medicine/article/view/3509 |
id |
doaj-7a73ce055ca743a8a6912cc0f2625604 |
---|---|
record_format |
Article |
spelling |
doaj-7a73ce055ca743a8a6912cc0f26256042020-11-24T23:53:23ZengPeoples’ Friendship University of Russia (RUDN University)RUDN Journal of Medicine2313-02452313-02612010-09-010364673509Impact of intravitreous injection of additional volume of liquid on intraocular pressureA P Ermolaev0B S Pershin1V K Surguch2V F Mustyats3НИИ глазных болезней РАМННИИ глазных болезней РАМННИИ глазных болезней РАМНРоссийский университет дружбы народовThis work is about investigation of condition of intraocular pressure (IOP) after intravitreous injection of medicine avastine into eyeball with normal hydrodynamic. Injections were made for treatment of neovascular chorioretinal membrane plainly. The medicine was injected intravitreously in volume 0,05 ml with a special needle 30 gauge. IOP was measured by special surgical ophthalmotonometer of own construction. Measuring of IOP were made before injection, and also 30 seconds, 3 and 5 minutes after injection. Just after injection we discovered that IOP rose to 65 mm of hydrargerum. 5 minutes after IOP dropped down to 27 mm. Patients didn't have any pains or other unpleasant feelings in the eyeball although the IOP was very high at the moment.http://journals.rudn.ru/medicine/article/view/3509интравитреальное введениевнутриглазное давлениеофтальмотонометргидродинамический баланс глазавитреальная полостькомпенсаторная стабилизация внутриглазного давлениябевацизумаб |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
A P Ermolaev B S Pershin V K Surguch V F Mustyats |
spellingShingle |
A P Ermolaev B S Pershin V K Surguch V F Mustyats Impact of intravitreous injection of additional volume of liquid on intraocular pressure RUDN Journal of Medicine интравитреальное введение внутриглазное давление офтальмотонометр гидродинамический баланс глаза витреальная полость компенсаторная стабилизация внутриглазного давления бевацизумаб |
author_facet |
A P Ermolaev B S Pershin V K Surguch V F Mustyats |
author_sort |
A P Ermolaev |
title |
Impact of intravitreous injection of additional volume of liquid on intraocular pressure |
title_short |
Impact of intravitreous injection of additional volume of liquid on intraocular pressure |
title_full |
Impact of intravitreous injection of additional volume of liquid on intraocular pressure |
title_fullStr |
Impact of intravitreous injection of additional volume of liquid on intraocular pressure |
title_full_unstemmed |
Impact of intravitreous injection of additional volume of liquid on intraocular pressure |
title_sort |
impact of intravitreous injection of additional volume of liquid on intraocular pressure |
publisher |
Peoples’ Friendship University of Russia (RUDN University) |
series |
RUDN Journal of Medicine |
issn |
2313-0245 2313-0261 |
publishDate |
2010-09-01 |
description |
This work is about investigation of condition of intraocular pressure (IOP) after intravitreous injection of medicine avastine into eyeball with normal hydrodynamic. Injections were made for treatment of neovascular chorioretinal membrane plainly. The medicine was injected intravitreously in volume 0,05 ml with a special needle 30 gauge. IOP was measured by special surgical ophthalmotonometer of own construction. Measuring of IOP were made before injection, and also 30 seconds, 3 and 5 minutes after injection. Just after injection we discovered that IOP rose to 65 mm of hydrargerum. 5 minutes after IOP dropped down to 27 mm. Patients didn't have any pains or other unpleasant feelings in the eyeball although the IOP was very high at the moment. |
topic |
интравитреальное введение внутриглазное давление офтальмотонометр гидродинамический баланс глаза витреальная полость компенсаторная стабилизация внутриглазного давления бевацизумаб |
url |
http://journals.rudn.ru/medicine/article/view/3509 |
work_keys_str_mv |
AT apermolaev impactofintravitreousinjectionofadditionalvolumeofliquidonintraocularpressure AT bspershin impactofintravitreousinjectionofadditionalvolumeofliquidonintraocularpressure AT vksurguch impactofintravitreousinjectionofadditionalvolumeofliquidonintraocularpressure AT vfmustyats impactofintravitreousinjectionofadditionalvolumeofliquidonintraocularpressure |
_version_ |
1725470039716397056 |