Vibration in a Multistage Centrifugal Pump under Varied Conditions

Multistage pumps are intended to improve designs with low-vibration and -noise features as the industry applications increase the technical requirements. In this frame, it becomes really important to fully understand the vibration patterns of these kinds of complex machines. In this study, a vibrati...

Full description

Bibliographic Details
Main Authors: Ling Bai, Ling Zhou, Xiaoping Jiang, Qinglong Pang, Daoxing Ye
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:Shock and Vibration
Online Access:http://dx.doi.org/10.1155/2019/2057031
id doaj-7a6276f58a5e4fa9ba7ff4a576542589
record_format Article
spelling doaj-7a6276f58a5e4fa9ba7ff4a5765425892020-11-25T02:28:56ZengHindawi LimitedShock and Vibration1070-96221875-92032019-01-01201910.1155/2019/20570312057031Vibration in a Multistage Centrifugal Pump under Varied ConditionsLing Bai0Ling Zhou1Xiaoping Jiang2Qinglong Pang3Daoxing Ye4National Research Center of Pumps, Jiangsu University, Zhenjiang 212013, ChinaNational Research Center of Pumps, Jiangsu University, Zhenjiang 212013, ChinaNational Engineering and Technology Center for Information Agriculture, Nanjing 210095, ChinaNational Research Center of Pumps, Jiangsu University, Zhenjiang 212013, ChinaKey Laboratory of Fluid and Power Machinery, Ministry of Education, Xihua University, Chengdu 610039, ChinaMultistage pumps are intended to improve designs with low-vibration and -noise features as the industry applications increase the technical requirements. In this frame, it becomes really important to fully understand the vibration patterns of these kinds of complex machines. In this study, a vibration test bench was established to examine the vibration and stability of a cantilever multistage centrifugal pump under different flow rates. The vibration spectrum diagrams for the inlet and outlet sections and the pump body were evaluated under varied flow conditions. Results showed the effects of operational conditions on the vibration of the cantilever multistage centrifugal pump. Vibration velocity was primarily caused by mass unbalance at the shut-off flow rate point. Under different flow conditions, the blade passing frequency (BPF) and two times the blade passing frequency (2BPF) were the main excitation frequencies. The vibration frequency of the final pump body remained at the BPF under different flow conditions due to the contact with the outlet section. The major type of vibration frequency for the inlet and outlet was high frequency.http://dx.doi.org/10.1155/2019/2057031
collection DOAJ
language English
format Article
sources DOAJ
author Ling Bai
Ling Zhou
Xiaoping Jiang
Qinglong Pang
Daoxing Ye
spellingShingle Ling Bai
Ling Zhou
Xiaoping Jiang
Qinglong Pang
Daoxing Ye
Vibration in a Multistage Centrifugal Pump under Varied Conditions
Shock and Vibration
author_facet Ling Bai
Ling Zhou
Xiaoping Jiang
Qinglong Pang
Daoxing Ye
author_sort Ling Bai
title Vibration in a Multistage Centrifugal Pump under Varied Conditions
title_short Vibration in a Multistage Centrifugal Pump under Varied Conditions
title_full Vibration in a Multistage Centrifugal Pump under Varied Conditions
title_fullStr Vibration in a Multistage Centrifugal Pump under Varied Conditions
title_full_unstemmed Vibration in a Multistage Centrifugal Pump under Varied Conditions
title_sort vibration in a multistage centrifugal pump under varied conditions
publisher Hindawi Limited
series Shock and Vibration
issn 1070-9622
1875-9203
publishDate 2019-01-01
description Multistage pumps are intended to improve designs with low-vibration and -noise features as the industry applications increase the technical requirements. In this frame, it becomes really important to fully understand the vibration patterns of these kinds of complex machines. In this study, a vibration test bench was established to examine the vibration and stability of a cantilever multistage centrifugal pump under different flow rates. The vibration spectrum diagrams for the inlet and outlet sections and the pump body were evaluated under varied flow conditions. Results showed the effects of operational conditions on the vibration of the cantilever multistage centrifugal pump. Vibration velocity was primarily caused by mass unbalance at the shut-off flow rate point. Under different flow conditions, the blade passing frequency (BPF) and two times the blade passing frequency (2BPF) were the main excitation frequencies. The vibration frequency of the final pump body remained at the BPF under different flow conditions due to the contact with the outlet section. The major type of vibration frequency for the inlet and outlet was high frequency.
url http://dx.doi.org/10.1155/2019/2057031
work_keys_str_mv AT lingbai vibrationinamultistagecentrifugalpumpundervariedconditions
AT lingzhou vibrationinamultistagecentrifugalpumpundervariedconditions
AT xiaopingjiang vibrationinamultistagecentrifugalpumpundervariedconditions
AT qinglongpang vibrationinamultistagecentrifugalpumpundervariedconditions
AT daoxingye vibrationinamultistagecentrifugalpumpundervariedconditions
_version_ 1724835472720527360