Influence of High-Speed Train Power Consumption and Arc Fault Resistances on a Novel Ground Fault Location Method for 2 × 25 kV Railway Power Supply Systems
The 2 × 25 kV power supply system is the most frequently used traction rail system to provide the huge power needed by high-speed trains. However, locating the ground fault in this power supply system is more complicated than in other configurations of electrical railway power supply due t...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2018-06-01
|
Series: | Energies |
Subjects: | |
Online Access: | http://www.mdpi.com/1996-1073/11/6/1601 |
id |
doaj-7a50af415c3542daa2abdf8a4b5a976f |
---|---|
record_format |
Article |
spelling |
doaj-7a50af415c3542daa2abdf8a4b5a976f2020-11-24T23:17:49ZengMDPI AGEnergies1996-10732018-06-01116160110.3390/en11061601en11061601Influence of High-Speed Train Power Consumption and Arc Fault Resistances on a Novel Ground Fault Location Method for 2 × 25 kV Railway Power Supply SystemsCarlos A. Platero0Jesús Serrano1Máximo López-Toledo2Ricardo Granizo3Department of Electrical Engineering, ETS Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal, 2, 28006 Madrid, SpainDepartment of Electrical Engineering, ETS Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal, 2, 28006 Madrid, SpainDepartment of Electrical Engineering, ETS Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal, 2, 28006 Madrid, SpainDepartment of Electrical Engineering, ETS Ingeniería y Diseño Industrial, Universidad Politécnica de Madrid, C/Ronda de Valencia, 3, 28012 Madrid, SpainThe 2 × 25 kV power supply system is the most frequently used traction rail system to provide the huge power needed by high-speed trains. However, locating the ground fault in this power supply system is more complicated than in other configurations of electrical railway power supply due to the installation of autotransformers throughout the line section. In previous papers, the authors have described a ground fault location method with an insignificant installation cost. The method and, moreover, the location discriminate between whether the ground fault is located between a positive conductor and ground or a negative conductor and ground. The current of the high-speed train influences the accuracy of the location of the ground fault. An additional factor which influences the location method is the existence of an arc resistance between the positive or negative conductor and ground. In this paper, the influence of high-speed train currents and arc resistances are analysed to evaluate the error in the location method. The major conclusion of the paper is that the location method has an acceptable precision even taking into consideration the high-speed train current and arc resistance. The validation of the method has been performed by laboratory tests and computer simulations with satisfactory results.http://www.mdpi.com/1996-1073/11/6/1601electrical protectionground faultsfault locationrailways power system2 × 25 kV |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Carlos A. Platero Jesús Serrano Máximo López-Toledo Ricardo Granizo |
spellingShingle |
Carlos A. Platero Jesús Serrano Máximo López-Toledo Ricardo Granizo Influence of High-Speed Train Power Consumption and Arc Fault Resistances on a Novel Ground Fault Location Method for 2 × 25 kV Railway Power Supply Systems Energies electrical protection ground faults fault location railways power system 2 × 25 kV |
author_facet |
Carlos A. Platero Jesús Serrano Máximo López-Toledo Ricardo Granizo |
author_sort |
Carlos A. Platero |
title |
Influence of High-Speed Train Power Consumption and Arc Fault Resistances on a Novel Ground Fault Location Method for 2 × 25 kV Railway Power Supply Systems |
title_short |
Influence of High-Speed Train Power Consumption and Arc Fault Resistances on a Novel Ground Fault Location Method for 2 × 25 kV Railway Power Supply Systems |
title_full |
Influence of High-Speed Train Power Consumption and Arc Fault Resistances on a Novel Ground Fault Location Method for 2 × 25 kV Railway Power Supply Systems |
title_fullStr |
Influence of High-Speed Train Power Consumption and Arc Fault Resistances on a Novel Ground Fault Location Method for 2 × 25 kV Railway Power Supply Systems |
title_full_unstemmed |
Influence of High-Speed Train Power Consumption and Arc Fault Resistances on a Novel Ground Fault Location Method for 2 × 25 kV Railway Power Supply Systems |
title_sort |
influence of high-speed train power consumption and arc fault resistances on a novel ground fault location method for 2 × 25 kv railway power supply systems |
publisher |
MDPI AG |
series |
Energies |
issn |
1996-1073 |
publishDate |
2018-06-01 |
description |
The 2 × 25 kV power supply system is the most frequently used traction rail system to provide the huge power needed by high-speed trains. However, locating the ground fault in this power supply system is more complicated than in other configurations of electrical railway power supply due to the installation of autotransformers throughout the line section. In previous papers, the authors have described a ground fault location method with an insignificant installation cost. The method and, moreover, the location discriminate between whether the ground fault is located between a positive conductor and ground or a negative conductor and ground. The current of the high-speed train influences the accuracy of the location of the ground fault. An additional factor which influences the location method is the existence of an arc resistance between the positive or negative conductor and ground. In this paper, the influence of high-speed train currents and arc resistances are analysed to evaluate the error in the location method. The major conclusion of the paper is that the location method has an acceptable precision even taking into consideration the high-speed train current and arc resistance. The validation of the method has been performed by laboratory tests and computer simulations with satisfactory results. |
topic |
electrical protection ground faults fault location railways power system 2 × 25 kV |
url |
http://www.mdpi.com/1996-1073/11/6/1601 |
work_keys_str_mv |
AT carlosaplatero influenceofhighspeedtrainpowerconsumptionandarcfaultresistancesonanovelgroundfaultlocationmethodfor225kvrailwaypowersupplysystems AT jesusserrano influenceofhighspeedtrainpowerconsumptionandarcfaultresistancesonanovelgroundfaultlocationmethodfor225kvrailwaypowersupplysystems AT maximolopeztoledo influenceofhighspeedtrainpowerconsumptionandarcfaultresistancesonanovelgroundfaultlocationmethodfor225kvrailwaypowersupplysystems AT ricardogranizo influenceofhighspeedtrainpowerconsumptionandarcfaultresistancesonanovelgroundfaultlocationmethodfor225kvrailwaypowersupplysystems |
_version_ |
1725583201158561792 |