Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range

In this paper, a thermo-optic tuning optical waveguide sensor system based on a cascaded double micro-ring resonator is investigated. The system consists of a micro-ring resonator with the microheater as a reference ring and a micro-ring resonator with removing the upper cladding layers as a sensing...

Full description

Bibliographic Details
Main Authors: Zhiping Yang, Yanlu Wang, Chang Su, Liyang Shao, Jian-Jun He, Mingyu Li
Format: Article
Language:English
Published: MDPI AG 2020-09-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/18/5149
id doaj-79e12396d92049c684c1d7c9cd1180b2
record_format Article
spelling doaj-79e12396d92049c684c1d7c9cd1180b22020-11-25T03:47:22ZengMDPI AGSensors1424-82202020-09-01205149514910.3390/s20185149Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement RangeZhiping Yang0Yanlu Wang1Chang Su2Liyang Shao3Jian-Jun He4Mingyu Li5Department of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, ChinaDepartment of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, ChinaState Key Laboratory of Modern Optical Instrumentation, Centre for Integrated Optoelectronics, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, ChinaDepartment of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen 518055, ChinaState Key Laboratory of Modern Optical Instrumentation, Centre for Integrated Optoelectronics, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, ChinaDepartment of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, ChinaIn this paper, a thermo-optic tuning optical waveguide sensor system based on a cascaded double micro-ring resonator is investigated. The system consists of a micro-ring resonator with the microheater as a reference ring and a micro-ring resonator with removing the upper cladding layers as a sensing ring, combined with a microfluidic control. The refractive index change of the sample is measured by the electric power change of the microheater. The experimental results show that the sensitivity of the thermo-optic tuning is 34.231 W/RIU (refractive index units), and the measurement range is 4.325 × 10<sup>−3</sup> RIU, almost eight times larger than that of the cascaded double micro-ring resonator without thermo-optic tuning for the intensity interrogation.https://www.mdpi.com/1424-8220/20/18/5149optical waveguidecascaded double micro-ring resonatorthermo-optical tuningintensity interrogation
collection DOAJ
language English
format Article
sources DOAJ
author Zhiping Yang
Yanlu Wang
Chang Su
Liyang Shao
Jian-Jun He
Mingyu Li
spellingShingle Zhiping Yang
Yanlu Wang
Chang Su
Liyang Shao
Jian-Jun He
Mingyu Li
Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range
Sensors
optical waveguide
cascaded double micro-ring resonator
thermo-optical tuning
intensity interrogation
author_facet Zhiping Yang
Yanlu Wang
Chang Su
Liyang Shao
Jian-Jun He
Mingyu Li
author_sort Zhiping Yang
title Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range
title_short Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range
title_full Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range
title_fullStr Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range
title_full_unstemmed Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range
title_sort thermo-optical tuning cascaded double ring sensor with large measurement range
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2020-09-01
description In this paper, a thermo-optic tuning optical waveguide sensor system based on a cascaded double micro-ring resonator is investigated. The system consists of a micro-ring resonator with the microheater as a reference ring and a micro-ring resonator with removing the upper cladding layers as a sensing ring, combined with a microfluidic control. The refractive index change of the sample is measured by the electric power change of the microheater. The experimental results show that the sensitivity of the thermo-optic tuning is 34.231 W/RIU (refractive index units), and the measurement range is 4.325 × 10<sup>−3</sup> RIU, almost eight times larger than that of the cascaded double micro-ring resonator without thermo-optic tuning for the intensity interrogation.
topic optical waveguide
cascaded double micro-ring resonator
thermo-optical tuning
intensity interrogation
url https://www.mdpi.com/1424-8220/20/18/5149
work_keys_str_mv AT zhipingyang thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange
AT yanluwang thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange
AT changsu thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange
AT liyangshao thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange
AT jianjunhe thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange
AT mingyuli thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange
_version_ 1724502179966877696