Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range
In this paper, a thermo-optic tuning optical waveguide sensor system based on a cascaded double micro-ring resonator is investigated. The system consists of a micro-ring resonator with the microheater as a reference ring and a micro-ring resonator with removing the upper cladding layers as a sensing...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-09-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/20/18/5149 |
id |
doaj-79e12396d92049c684c1d7c9cd1180b2 |
---|---|
record_format |
Article |
spelling |
doaj-79e12396d92049c684c1d7c9cd1180b22020-11-25T03:47:22ZengMDPI AGSensors1424-82202020-09-01205149514910.3390/s20185149Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement RangeZhiping Yang0Yanlu Wang1Chang Su2Liyang Shao3Jian-Jun He4Mingyu Li5Department of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, ChinaDepartment of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, ChinaState Key Laboratory of Modern Optical Instrumentation, Centre for Integrated Optoelectronics, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, ChinaDepartment of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen 518055, ChinaState Key Laboratory of Modern Optical Instrumentation, Centre for Integrated Optoelectronics, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, ChinaDepartment of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, ChinaIn this paper, a thermo-optic tuning optical waveguide sensor system based on a cascaded double micro-ring resonator is investigated. The system consists of a micro-ring resonator with the microheater as a reference ring and a micro-ring resonator with removing the upper cladding layers as a sensing ring, combined with a microfluidic control. The refractive index change of the sample is measured by the electric power change of the microheater. The experimental results show that the sensitivity of the thermo-optic tuning is 34.231 W/RIU (refractive index units), and the measurement range is 4.325 × 10<sup>−3</sup> RIU, almost eight times larger than that of the cascaded double micro-ring resonator without thermo-optic tuning for the intensity interrogation.https://www.mdpi.com/1424-8220/20/18/5149optical waveguidecascaded double micro-ring resonatorthermo-optical tuningintensity interrogation |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zhiping Yang Yanlu Wang Chang Su Liyang Shao Jian-Jun He Mingyu Li |
spellingShingle |
Zhiping Yang Yanlu Wang Chang Su Liyang Shao Jian-Jun He Mingyu Li Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range Sensors optical waveguide cascaded double micro-ring resonator thermo-optical tuning intensity interrogation |
author_facet |
Zhiping Yang Yanlu Wang Chang Su Liyang Shao Jian-Jun He Mingyu Li |
author_sort |
Zhiping Yang |
title |
Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range |
title_short |
Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range |
title_full |
Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range |
title_fullStr |
Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range |
title_full_unstemmed |
Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range |
title_sort |
thermo-optical tuning cascaded double ring sensor with large measurement range |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2020-09-01 |
description |
In this paper, a thermo-optic tuning optical waveguide sensor system based on a cascaded double micro-ring resonator is investigated. The system consists of a micro-ring resonator with the microheater as a reference ring and a micro-ring resonator with removing the upper cladding layers as a sensing ring, combined with a microfluidic control. The refractive index change of the sample is measured by the electric power change of the microheater. The experimental results show that the sensitivity of the thermo-optic tuning is 34.231 W/RIU (refractive index units), and the measurement range is 4.325 × 10<sup>−3</sup> RIU, almost eight times larger than that of the cascaded double micro-ring resonator without thermo-optic tuning for the intensity interrogation. |
topic |
optical waveguide cascaded double micro-ring resonator thermo-optical tuning intensity interrogation |
url |
https://www.mdpi.com/1424-8220/20/18/5149 |
work_keys_str_mv |
AT zhipingyang thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange AT yanluwang thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange AT changsu thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange AT liyangshao thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange AT jianjunhe thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange AT mingyuli thermoopticaltuningcascadeddoubleringsensorwithlargemeasurementrange |
_version_ |
1724502179966877696 |